JBL ON STAGE 200ID EMC - CB Certificate ▷ View online
- Page 20 of 63 -
Report
No.
98323
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
3.1.6
Screws for electrical contact pressure
No screw for electrical
contact.
contact.
N
3.1.7
Insulating materials in electrical connections
No contact pressure through
insulating material.
insulating material.
P
3.1.8
Self-tapping and spaced thread screws
Thread-cutting or space
thread screws are not used for
electrical connections.
thread screws are not used for
electrical connections.
P
3.1.9
Termination of conductors
Terminations cannot become
displaced so that clearances
and creepage distances can
be reduced.
displaced so that clearances
and creepage distances can
be reduced.
P
10 N pull test
Conducted.
P
3.1.10
Sleeving on wiring
Sleeves can only be removed
by breaking or cutting.
by breaking or cutting.
P
Measuring instrument
Inv. no.
Date
- Page 21 of 63 -
Report
No.
98323
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
3.2
Connection to a mains supply
⎯
3.2.1
Means of connection
Class III equipment. Unit is
not intended for direct
connection to a mains supply.
not intended for direct
connection to a mains supply.
⎯
3.2.1.1
Connection to an a.c. mains supply
⎯
3.2.1.2
Connection to a d.c. mains supply
⎯
3.2.2
Multiple supply connections
⎯
3.2.3
Permanently connected equipment
⎯
Number of conductors, diameter of cable and
conduits (mm) .......................................................:
conduits (mm) .......................................................:
⎯
3.2.4 Appliance
inlets
⎯
3.2.5
Power supply cords
⎯
3.2.5.1
AC power supply cords
⎯
Type
......................................................................:
⎯
Rated current (A), cross-sectional area (mm
2
),
AWG ......................................................................:
⎯
3.2.5.2
DC power supply cords
⎯
3.2.6
Cord anchorages and strain relief
⎯
Mass of equipment (kg), pull (N) ..........................:
⎯
Longitudinal
displacement (mm) ...........................:
⎯
3.2.7
Protection against mechanical damage
⎯
3.2.8 Cord
guards
⎯
Diameter or minor dimension D (mm); test mass (g)
...............................................................................:
⎯
Radius of curvature of cord (mm) ..........................:
⎯
3.2.9
Supply wiring space
⎯
Measuring instrument
Inv. no.
Date
3.3
Wiring terminals for connection of external conductors
⎯
- Page 22 of 63 -
Report
No.
98323
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
3.3.1
Wiring terminals
Class III equipment. Unit is
not intended for direct
connection to a mains supply.
not intended for direct
connection to a mains supply.
N
3.3.2
Connection of non-detachable power supply cords
N
3.3.3 Screw
terminals
N
3.3.4
Conductor sizes to be connected
N
Rated current (A), cord/cable type, cross-sectional
area (mm
area (mm
2
) .............................................................:
⎯
3.3.5
Wiring terminal sizes
N
Rated current (A), type, nominal thread diameter
(mm) ......................................................................:
(mm) ......................................................................:
⎯
3.3.6
Wiring terminal design
N
3.3.7
Grouping of wiring terminals
N
3.3.8 Stranded
wire
N
Measuring instrument
Inv. no.
Date
3.4
Disconnection from the mains supply
⎯
3.4.1
General requirement
Class III equipment. Unit is
not intended for direct
connection to a mains supply.
not intended for direct
connection to a mains supply.
N
3.4.2 Disconnect
devices
⎯
3.4.3
Permanently connected equipment
⎯
3.4.4
Parts which remain energized
⎯
3.4.5
Switches in flexible cords
⎯
3.4.6
Number of poles - single-phase and d.c. equipment
⎯
3.4.7
Number of poles - three-phase equipment
⎯
3.4.8 Switches
as
disconnect devices
⎯
3.4.9
Plugs as disconnect devices
⎯
3.4.10 Interconnected
equipment
⎯
3.4.11
Multiple power sources
⎯
- Page 23 of 63 -
Report
No.
98323
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
3.5
Interconnection of equipment
⎯
3.5.1 General
requirements
Considered.
⎯
3.5.2
Types of interconnection circuits ..........................: SELV
circuit.
P
3.5.3
ELV circuits as interconnection circuits
No ELV.
N
3.5.4
Data ports for additional equipment
The equipment powered by
Limited Power Source.
Limited Power Source.
P
Measuring instrument
Inv. no.
Date
4 PHYSICAL
REQUIREMENTS
⎯
4.1 Stability
⎯
Angle of 10
°
<7kg N
Test force (N) ........................................................ : The
unit
is not floor-standing.
N
Measuring instrument
Inv. no.
Date
4.2 Mechanical
strength
⎯
4.2.1
General
Class III equipment.
N
4.2.2
Steady force test, 10 N
N
4.2.3
Steady force test, 30 N
N
4.2.4
Steady force test, 250 N
N
4.2.5 Impact
test
N
Fall
test
N
Swing
test
N
4.2.6
Drop test; height (mm) .......................................... :
N
4.2.7
Stress relief test
N