JBL ON CALL (serv.man2) EMC - CB Certificate ▷ View online
Page 5 of 99
ST-06153
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
1 GENERAL
1.5 Components
1.5.1 General
P
Comply with IEC 60950-1 or relevant component
standard
standard
(see appended table 1.5.1)
P
1.5.2
Evaluation and testing of components
P
1.5.3
Thermal controls
No such devices within the EUT
N/A
1.5.4
Transformers
(see also Annex C)
P
1.5.5 Interconnecting
cables
The output cord is evaluated at
the relevant parts of this report
the relevant parts of this report
P
1.5.6
Capacitors in primary circuits ............................. : Approved X / Y capacitors
(see appended table 1.5.1)
P
1.5.7
Double insulation or reinforced insulation bridged
by components
by components
Double or reinforced insulation
between primary and
secondary bridged by Y1
capacitor, CY1
between primary and
secondary bridged by Y1
capacitor, CY1
P
1.5.7.1 General
P
1.5.7.2
Bridging capacitors
Approved Y1 capacitor, CY1
(see appended table 1.5.1)
(see appended table 1.5.1)
P
1.5.7.3
Bridging resistors
No such components within the
EUT
EUT
N/A
1.5.7.4
Accessible parts
See sub-clause 2.4
P
1.5.8
Components in equipment for IT power systems
N/A
1.6 Power
interface
1.6.1
AC power distribution systems
TN, TT or IT (only for Norway)
P
1.6.2 Input
current
(see
appended table 1.6.2)
P
1.6.3
Voltage limit of hand-held equipment
The EUT is not hand-held
equipment
equipment
N/A
1.6.4
Neutral conductor
P
Page 6 of 99
ST-06153
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
1.7
Marking and instructions
1.7.1 Power
rating
P
Rated voltage(s) or voltage range(s) (V) ............ : 100
− 240 Vac
P
Symbol for nature of supply, for d.c. only............ : The EUT is supplied by AC
mains
N/A
Rated frequency or rated frequency range (Hz) : 50 / 60 Hz
P
Rated
current
(mA
or A) ..................................... : 0.5 A
P
Manufacturer’s name or trademark or
identification mark .............................................. :
identification mark .............................................. :
LEI P
Type/model or type reference ............................. : MU15-C******-**
P
Symbol of for Class II equipment only ............... :
P
Other
symbols
....................................................: Symbols are used according to
IEC 60417-1
P
Certification
marks ............................................. :
N/A
1.7.2
Safety instructions
The English “I.T.E. POWER
SUPPLY” will be provided with
the unit
SUPPLY” will be provided with
the unit
P
1.7.3
Short duty cycles
The EUT is continuous
operating type
operating type
N/A
1.7.4
Supply voltage adjustment ................................. : Only one power supply voltage
range
N/A
1.7.5
Power outlets on the equipment ........................ : No such components within the
EUT
N/A
1.7.6 Fuse
identification .............................................. : The “F1” and “T1AL250V” are
marked adjacent to the main
fuse
fuse
P
1.7.7
Wiring terminals
Class II equipment
N/A
1.7.7.1 Protective
earthing
and bonding terminals ........ :
N/A
1.7.7.2
Terminal for a.c. mains supply conductors
N/A
1.7.7.3
Terminals for d.c. mains supply conductors
N/A
1.7.8 Controls
and
indicators
No
controls or indicators within
the EUT
N/A
1.7.8.1 Identification,
location and marking .................... :
N/A
Page 7 of 99
ST-06153
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
1.7.8.2 Colours .............................................................. :
N/A
1.7.8.3 Symbols
according to IEC 60417........................ :
N/A
1.7.8.4
Markings using figures ...................................... : No figures used as marking
N/A
1.7.9
Isolation of multiple power sources .................... : Only one power supply
N/A
1.7.10
IT power distribution systems
Only for Norway
P
1.7.11
Thermostats and other regulating devices
No such devices within the EUT
N/A
1.7.12 Language
........................................................... : English and local language to
each country that would be
marketed
marketed
1.7.13 Durability
P
1.7.14
Removable parts
No such parts
N/A
1.7.15
Replaceable batteries
No battery within the EUT
N/A
Language ............................................................ :
1.7.16
Operator access with a tool ................................ : No such areas
N/A
1.7.17
Equipment for restricted access locations .......... : The EUT is not such types
N/A
Page 8 of 99
ST-06153
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
2
PROTECTION FROM HAZARDS
2.1
Protection from electric shock and energy hazards
2.1.1
Protection in operator access areas
P
2.1.1.1
Access to energized parts
See comment below
P
Test by inspection .............................................. : The concerned hazardous parts
are not accessible
P
Test with test finger ............................................ : The concerned hazardous parts
are not accessible
P
Test with test pin ................................................ : Hazardous live parts are not
accessible
P
Test with test probe ............................................ : No TNV circuit within the EUT
N/A
2.1.1.2 Battery
compartments ........................................ : No battery compartment within
the EUT
N/A
2.1.1.3
Access to ELV wiring
No ELV circuit within the EUT
N/A
Working voltage (V); minimum distance (mm)
through insulation
through insulation
2.1.1.4
Access to hazardous voltage circuit wiring
N/A
2.1.1.5 Energy
hazards
.................................................. : (see appended table 2.1.1.5)
P
2.1.1.6
Manual controls
No such devices
N/A
2.1.1.7
Discharge of capacitors in equipment
P
Time-constant (s); measured voltage (V)............ : 1 s, 0 Vpeak (limit: measured
max. voltage 370 Vpeak x 37 %
= 137 Vpeak, 0.33 ms)
= 137 Vpeak, 0.33 ms)
2.1.2
Protection in service access areas
No such areas
N/A
2.1.3
Protection in restricted access locations
No such areas
N/A
2.2 SELV
circuits
2.2.1 General
requirements
P
2.2.2
Voltages under normal conditions (V)................. : Measured max. 24.1 Vdc
(See also the Note on next
page)
page)
P
2.2.3
Voltages under fault conditions (V) ..................... : Measured max. 23.5 Vdc (see
also appended table 5.3)
P
2.2.3.1
Separation by double insulation or reinforced
insulation (method 1)
insulation (method 1)
P