JBL ON CALL (serv.man2) EMC - CB Certificate ▷ View online

 
 
 
 
Page 5 of 99 
ST-06153 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
1 GENERAL 
 
 
1.5 Components 
 
1.5.1 General 
 
 
Comply with IEC 60950-1 or relevant component 
standard  
(see appended table 1.5.1) 
1.5.2 
Evaluation and testing of components 
 
1.5.3 
Thermal controls 
No such devices within the EUT 
N/A 
1.5.4 
Transformers 
(see also Annex C) 
1.5.5 Interconnecting 
cables 
The output cord is evaluated at 
the relevant parts of this report 
1.5.6 
Capacitors in primary circuits ............................. : Approved X / Y capacitors 
(see appended table 1.5.1) 
1.5.7 
Double insulation or reinforced insulation bridged 
by components 
Double or reinforced insulation 
between primary and 
secondary bridged by Y1 
capacitor, CY1 
1.5.7.1 General 
 
1.5.7.2 
Bridging capacitors 
Approved Y1 capacitor, CY1 
(see appended table 1.5.1) 
1.5.7.3 
Bridging resistors 
No such components within the 
EUT 
N/A 
1.5.7.4 
Accessible parts 
See sub-clause 2.4  
1.5.8 
Components in equipment for IT power systems 
 
N/A 
 
1.6 Power 
interface 
 
1.6.1 
AC power distribution systems 
TN, TT or IT (only for Norway) 
1.6.2 Input 
current 
(see 
appended table 1.6.2)  
1.6.3 
Voltage limit of hand-held equipment 
The EUT is not hand-held 
equipment 
N/A 
1.6.4 
Neutral conductor  
 
 
 
 
 
 
Page 6 of 99 
ST-06153 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
1.7 
Marking and instructions 
 
1.7.1 Power 
rating 
 
 
 
Rated voltage(s) or voltage range(s) (V) ............ : 100 
− 240 Vac 
 
Symbol for nature of supply, for d.c. only............ : The EUT is supplied by AC 
mains 
N/A 
 
Rated frequency or rated frequency range (Hz)  : 50 / 60 Hz 
 Rated 
current 
(mA 
or A) ..................................... : 0.5 A 
 
Manufacturer’s name or trademark or 
identification mark  .............................................. :
LEI P 
 
Type/model or type reference ............................. : MU15-C******-**  
 
Symbol of for Class II equipment only  ............... :
 
 Other 
symbols 
....................................................: Symbols are used according to 
IEC 60417-1 
 Certification 
marks ............................................. :  
N/A 
1.7.2 
Safety instructions 
The English “I.T.E. POWER 
SUPPLY” will be provided with 
the unit 
1.7.3 
Short duty cycles 
The EUT is continuous 
operating type 
N/A 
1.7.4 
Supply voltage adjustment ................................. : Only one power supply voltage 
range  
N/A 
1.7.5 
Power outlets on the equipment  ........................ : No such components within the 
EUT 
N/A 
1.7.6 Fuse 
identification .............................................. : The “F1” and “T1AL250V” are 
marked adjacent to the main 
fuse  
1.7.7 
Wiring terminals 
Class II equipment 
N/A 
1.7.7.1 Protective 
earthing 
and bonding terminals  ........ :  
N/A 
1.7.7.2 
Terminal for a.c. mains supply conductors  
 
N/A 
1.7.7.3 
Terminals for d.c. mains supply conductors 
 
N/A 
1.7.8 Controls 
and 
indicators 
No 
controls or indicators within 
the EUT 
N/A 
1.7.8.1 Identification, 
location and marking .................... :  
N/A 
 
 
 
 
Page 7 of 99 
ST-06153 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
1.7.8.2 Colours  .............................................................. :  
N/A 
1.7.8.3 Symbols 
according to IEC 60417........................ :  
N/A 
1.7.8.4 
Markings using figures   ...................................... : No figures used as marking 
N/A 
1.7.9 
Isolation of multiple power sources .................... : Only one power supply 
N/A 
1.7.10 
IT power distribution systems  
Only for Norway 
1.7.11 
Thermostats and other regulating devices  
No such devices within the EUT 
N/A 
1.7.12 Language 
........................................................... : English and local language to 
each country that would be 
marketed 
 
1.7.13 Durability 
 
1.7.14 
Removable parts 
No such parts 
N/A 
1.7.15 
Replaceable batteries 
No battery within the EUT 
N/A 
 Language ............................................................ :  
 
1.7.16 
Operator access with a tool ................................ : No such areas 
N/A 
1.7.17 
Equipment for restricted access locations .......... : The EUT is not such types 
N/A 
 
 
 
 
 
Page 8 of 99 
ST-06153 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
PROTECTION FROM HAZARDS 
 
 
2.1 
Protection from electric shock and energy hazards 
 
2.1.1 
Protection in operator access areas  
 
2.1.1.1 
Access to energized parts 
See comment below  
 
Test by inspection .............................................. : The concerned hazardous parts 
are not accessible 
 
Test with test finger ............................................ : The concerned hazardous parts 
are not accessible 
 
Test with test pin  ................................................ : Hazardous live parts are not 
accessible 
 
Test with test probe ............................................ : No TNV circuit within the EUT 
N/A 
2.1.1.2 Battery 
compartments ........................................ : No battery compartment within 
the EUT 
N/A 
2.1.1.3 
Access to ELV wiring 
No ELV circuit within the EUT 
N/A 
 
Working voltage (V); minimum distance (mm) 
through insulation 
 
 
2.1.1.4 
Access to hazardous voltage circuit wiring 
 
N/A 
2.1.1.5 Energy 
hazards 
.................................................. : (see appended table 2.1.1.5) 
2.1.1.6 
Manual controls 
No such devices 
N/A 
2.1.1.7 
Discharge of capacitors in equipment 
 
 
Time-constant (s); measured voltage (V)............ : 1 s, 0 Vpeak (limit: measured 
max. voltage 370 Vpeak x 37 % 
= 137 Vpeak, 0.33 ms) 
 
2.1.2 
Protection in service access areas 
No such areas 
N/A 
2.1.3 
Protection in restricted access locations 
No such areas 
N/A 
 
2.2 SELV 
circuits 
 
2.2.1 General 
requirements 
 
2.2.2 
Voltages under normal conditions (V)................. : Measured max. 24.1 Vdc 
(See also the Note on next 
page) 
2.2.3 
Voltages under fault conditions (V) ..................... : Measured max. 23.5 Vdc (see 
also appended table 5.3) 
2.2.3.1 
Separation by double insulation or reinforced 
insulation (method 1) 
 P 
Page of 127
Display