DOWNLOAD LG LS-L1260CL Service Manual ↓ Size: 1.44 MB | Pages: 60 in PDF or view online for FREE

Model
LS-L1260CL
Pages
60
Size
1.44 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
ls-l1260cl.zip
Date

LG LS-L1260CL Service Manual ▷ View online

Functions
• Room temperature sensor. (THERMISTOR)
• Maintains the room temperature in accordance with the Setting Temp. 
• Indoor fan is delayed for 5 sec at the starting.
• Restarting is inhibited for approx. 3 minutes.
• High, Med, Low, CHAOS
--- Lights up in operation
--- Lights up in Sleep Mode
--- Lights up in Timer Mode
--- Lights up in Defrost Mode (for Heating Model)
OUTDOOR --- Lights up in compressor operation (for Cooling Model)
• Intermittent operation of fan at low speed.
• The fan is switched to low(Cooling), med(Heating) speed.
• The unit will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
• The fan is switched to intermittent or irregular operation
• The fan speed is automatically switched from high to low speed. 
• The louver can be set at the desired position or swing 
up and down automatically. 
Indoor Unit
Operation ON/OFF by Remote controller
Sensing the Room Temperature
Room temperature control
Starting Current Control
Time Delay Safety Control
Indoor Fan Speed Control
Operation indication Lamps (LED)
Soft Dry Operation Mode
ƒU
Both the indoor and outdoor fan
stops during defrosting.
ƒU
The indoor fan stops until the 
evaporator pipe temperature will be
reached at 28°C.
Sleep Mode Auto Control
Natural Air Control by CHAOS Logic
Airflow Direction Control
-3-
Defrost(Deice) control (Heating)
Hot-start Control (Heating)
-4-
Soft Dry Operation Mode.(       )
Remote Controller
Operation ON/OFF
Reset
Operation Mode Selection
Temperature Setting
Timer Selection
Timer Setting
JET COOL
Timer Cancel
Sleep Operation
Airflow Direction Control
(Cooling 
model only)
(Heating 
model only)
TEMPERATURE
LOW
HIGH
Cooling Operation Mode.(       )
Heating Operation Mode.(       )
Auto Operation Mode.(       )
Fan Operation Mode
Room, Temperature Display
Setting the Time or Timer
ON
OFF
SET
CANCEL
Fan Speed Selection
(Low)
(Med)
(High)
(CHAOS)
: (High: 39°C                   LOW : 11°C)
Down to 18°C
Up to 30°C
Cooling
: OFF, ON, OFF               ON
: Cancel Sleep Mode, Timer ON or Timer OFF
: 1, 2, 3, 4, 5, 6, 7, Off Timer
: Fan Operates without cooling or heating.
Down to 16°C
Up to 30°C
Heating
-34-
Operation 
(1) Name and Function-Remote Control (Cooling Models)
Signal transmitter
Transmits the signals
to the room air conditioner.
Remote Control 
ON
OFF
SET
CANCEL
Signal transmitter
9
10
11
5
1
12
2
6
13
4
3
7
8
START/STOP BUTTON
Operation starts when this button is pressed and stops
when the button is pressed again.
ROOM TEMPERATURE SETTING BUTTONS
Used to select the room temperature.
INDOOR FAN SPEED SELECTOR
Used to select fan speed in four steps
low, medium, high, or CHAOS.
JET COOL
Used to start or stop the speed 
cooling. (Speed cooling operates 
super high fan speed in cooling mode.)
CHAOS SWING BUTTON
Used to stop or start louver movement and 
set the desired up/down airflow direction.
ON/OFF TIMER BUTTONS
Used to set the time of starting and stopping operation.
TIME SETTING BUTTONS
Used to adjust the time.
TIMER SET/CANCEL BUTTONS
Used to set the timer when the desired time is obtained
and to cancel the Timer operation.
SLEEP MODE AUTO BUTTON
Used to set Sleep Mode Auto operation.
AIR CIRCULATION BUTTON
Used to circulate the room air without cooling or heating
(turns indoor fan on/off).
ROOM TEMPERATURE CHECKING BUTTON
Used to check the room temperature.
RESET BUTTON
Used prior to resetting time or after replacing batteries.
OPERATION MODE SELECTION BUTTON
Used to select the operation mode.
1
2
3
4
5
6
7
8
9
10
11
12
13
-35-
(2) Name and Function-Remote Control  (Heat Pump Models)
Signal transmitter
Transmits the signals
to the room air conditioner.
Remote Control 
ON
OFF
SET
CANCEL
Signal transmitter
9
10
11
5
1
12
2
6
13
4
3
7
8
START/STOP BUTTON
Operation starts when this button is pressed and stops
when the button is pressed again.
ROOM TEMPERATURE SETTING BUTTONS
Used to select the room temperature.
INDOOR FAN SPEED SELECTOR
Used to select fan speed in four steps
low, medium, high, or CHAOS.
JET COOL
Used to start or stop the speed 
cooling. (Speed cooling operates 
super high fan speed in cooling mode.)
CHAOS SWING BUTTON
Used to stop or start louver movement and 
set the desired up/down airflow direction.
ON/OFF TIMER BUTTONS
Used to set the time of starting and stopping operation.
TIME SETTING BUTTONS
Used to adjust the time.
TIMER SET/CANCEL BUTTONS
Used to set the timer when the desired time is obtained
and to cancel the Timer operation.
SLEEP MODE AUTO BUTTON
Used to set Sleep Mode Auto operation.
AIR CIRCULATION BUTTON
Used to circulate the room air without cooling or heating
(turns indoor fan on/off).
ROOM TEMPERATURE CHECKING BUTTON
Used to check the room temperature.
RESET BUTTON
Used prior to resetting time or after replacing batteries.
OPERATION MODE SELECTION BUTTON
Used to select the operation mode.
1
2
3
4
5
6
7
8
9
10
11
12
13
Page of 60
Display

LG LS-L1260CL Service Manual ▷ Download

  • DOWNLOAD LG LS-L1260CL Service Manual ↓ Size: 1.44 MB | Pages: 60 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the LG LS-L1260CL in PDF for free, which will help you to disassemble, recover, fix and repair LG LS-L1260CL Air Conditioner. Information contained in LG LS-L1260CL Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.