JBL ON CALL (serv.man2) EMC - CB Certificate ▷ View online
Page 33 of 99
ST-06153
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
D
ANNEX D, MEASURING INSTRUMENTS FOR TOUCH-CURRENT TESTS
P
D.1 Measuring
instrument
P
D.2
Alternative measuring instrument
N/A
E
ANNEX E, TEMPERATURE RISE OF A WINDING
N/A
F
ANNEX F, MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES
(see 2.10)
(see 2.10)
P
G
ANNEX G, ALTERNATIVE METHOD FOR DETERMINING MINIMUM
CLEARANCES
CLEARANCES
N/A
G.1
Summary of the procedure for determining
minimum clearances
minimum clearances
N/A
G.2
Determination of mains transient voltage (V)...... :
N/A
G.2.1
AC mains supply
N/A
G.2.2 DC
mains
supply
N/A
G.3
Determination of telecommunication network
transient voltage (V)............................................ :
transient voltage (V)............................................ :
N/A
G.4
Determination of required withstand voltage (V). :
N/A
G.5
Measurement of transient levels (V) ................... :
N/A
G.6
Determination of minimum clearances................ :
N/A
H
ANNEX H, IONIZING RADIATION (see 4.3.13)
N/A
J
ANNEX J, TABLE OF ELECTROCHEMICAL POTENTIALS (see 2.6.5.6)
N/A
Metal
used
.......................................................... :
K
ANNEX K, THERMAL CONTROLS (see 1.5.3 and 5.3.7)
N/A
K.1
Making and breaking capacity
N/A
K.2
Thermostat reliability; operating voltage (V) ....... :
N/A
K.3
Thermostat endurance test; operating voltage
(V) ..................................................................... :
(V) ..................................................................... :
N/A
Page 34 of 99
ST-06153
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
K.4
Temperature limiter endurance; operating voltage
(V) ....................................................................... :
(V) ....................................................................... :
N/A
K.5
Thermal cut-out reliability
N/A
K.6
Stability of operation
N/A
L
ANNEX L, NORMAL LOAD CONDITIONS FOR SOME TYPES OF ELECTRICAL
BUSINESS EQUIPMENT (see 1.2.2.1 and 4.5.1)
BUSINESS EQUIPMENT (see 1.2.2.1 and 4.5.1)
P
L.1
Typewriters
N/A
L.2
Adding machines and cash registers
N/A
L.3 Erasers
N/A
L.4 Pencil
sharpeners
N/A
L.5
Duplicators and copy machines
N/A
L.6 Motor-operated
files
N/A
L.7
Other business equipment
Maximum rated output load
P
M
ANNEX M, CRITERIA FOR TELEPHONE RINGING SIGNALS (see 2.3.1)
N/A
M.1 Introduction
N/A
M.2
Method A
N/A
M.3 Method
B
N/A
M.3.1 Ringing
signal
N/A
M.3.1.1 Frequency
(Hz)
.................................................. :
M.3.1.2 Voltage (V) ......................................................... :
M.3.1.3 Cadence;
time (s), voltage (V) ........................... :
M.3.1.4 Single
fault current (mA) ..................................... :
M.3.2
Tripping device and monitoring voltage .............. :
N/A
M.3.2.1
Conditions for use of a tripping device or a
monitoring voltage
monitoring voltage
N/A
M.3.2.2 Tripping
device
N/A
M.3.2.3 Monitoring
voltage (V)......................................... :
N/A
Page 35 of 99
ST-06153
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
N
ANNEX N, IMPULSE TEST GENERATORS (see 2.10.3.4, 6.2.2.1, 7.3.2 and
clause G.5)
clause G.5)
N/A
N.1
ITU-T impulse test generators
N/A
N.2
IEC 60065 impulse test generator
N/A
P
ANNEX P, NORMATIVE REFERENCES
P
Q
ANNEX Q, BIBLIOGRAPHY
P
R
ANNEX R, EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL
PROGRAMMES
PROGRAMMES
N/A
R.1
Minimum separation distances for unpopulated
coated printed boards (see 2.10.6)
coated printed boards (see 2.10.6)
N/A
R.2
Reduced clearances (see 2.10.3)
N/A
S
ANNEX S, PROCEDURE FOR IMPULSE TESTING (see 6.2.2.3)
N/A
S.1 Test
equipment
N/A
S.2 Test
procedure
N/A
S.3
Examples of waveforms during impulse testing
N/A
T
ANNEX T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER
(see 1.1.2)
(see 1.1.2)
N/A
Separate test report
U
ANNEX U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED
INSULATION (see 2.10.5.4)
INSULATION (see 2.10.5.4)
P
Separate test report
(See appended table 1.5.1)
V
ANNEX V, AC POWER DISTRIBUTION SYSTEMS (see 1.6.1)
P
V.1 Introduction
P
V.2
TN power distribution systems
P
V.3
TT power distribution systems
P
V.4
IT power distribution systems
Only for Norway
P
Page 36 of 99
ST-06153
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
1.5.1
TABLE: list of critical components
P
object/part No.
manufacturer/
trademark
trademark
type/model
technical data
standard
mark(s) of
conformity
conformity
1)
Fuse (F1)
Walter
ICP
T 1 A, 250 V, LBC
IEC 60127
VDE
Alt.
Conquer
PTU
T 1 A, 250 V, LBC
IEC 60127
VDE
Alt.
Sleek
36ES
T 1 A, 250 V, LBC
IEC 60127
TÜV
X-Capacitor
(CX1)
(CX1)
UTX HQX
X2, max. 0.1
µF,
min. 275 V, 100 °C
IEC 60384-14,
2
2
nd
edition
VDE
Alt. Arcotronics
R.46
X2, max. 0.1
µF,
min. 275 V, 100 °C
IEC 60384-14,
2
2
nd
edition
FI
Alt. Okaya
LE
series
X2, max. 0.1
µF,
min. 275 V, 100 °C
IEC 60384-14,
2
2
nd
edition
FI
Alt. Pilkor
PCX2
337M
X2, max. 0.1
µF,
min. 275 V, 100 °C
IEC 60384-14,
2
2
nd
edition
VDE
Alt. Matsushita
ECQUL
X2, max. 0.1
µF,
min. 275 V, 100 °C
IEC 60384-14,
2
2
nd
edition
VDE
Alt. Carli MPX
X2, max. 0.1
µF,
min. 275 V, 100 °C
IEC 60384-14,
2
2
nd
edition
VDE
Alt. Cheng
Tung
CTX
X2, max. 0.1
µF,
min. 275 V, 100 °C
IEC 60384-14,
2
2
nd
edition
FI
Alt. Iskra
KNB1530,
KNB1560
KNB1560
X2, max. 0.1
µF,
min. 275 V, 100 °C
IEC 60384-14,
2
2
nd
edition
VDE
Alt. Su
Rong
X2
X2, max. 0.1
µF,
min. 275 V, 100 °C
IEC 60384-14,
2
2
nd
edition
VDE
Y-Capacitor
(CY1)
(CY1)
TDK
CD
Y1, max. 2200 pF,
min. 250 V, 125 °C
min. 250 V, 125 °C
IEC 60384-14,
2
2
nd
edition
VDE
Alt.
Welson
WD
Y1, max. 2200 pF,
min. 250 V, 125 °C
min. 250 V, 125 °C
IEC 60384-14,
2
2
nd
edition
VDE
Alt.
Jya-Nay
JN
Y1, max. 2200 pF,
min. 250 V, 125 °C
min. 250 V, 125 °C
IEC 60384-14,
2
2
nd
edition
VDE
Alt.
Murata
KH
Y1, max. 2200 pF,
min. 250 V, 125 °C
min. 250 V, 125 °C
IEC 60384-14,
2
2
nd
edition
VDE
Alt.
Pan Overseas
AH
Y1, max. 2200 pF,
min. 250 V, 125 °C
min. 250 V, 125 °C
IEC 60384-14,
2
2
nd
edition
VDE
Alt. Shantou
High-
New Technology
CD
Y1, max. 2200 pF,
min. 250 V, 125 °C
min. 250 V, 125 °C
IEC 60384-14,
2
2
nd
edition
VDE