DOWNLOAD JBL ON CALL (serv.man2) Service Manual ↓ Size: 1.63 MB | Pages: 127 in PDF or view online for FREE

Model
ON CALL (serv.man2)
Pages
127
Size
1.63 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
on-call-sm2.pdf
Date

JBL ON CALL (serv.man2) EMC - CB Certificate ▷ View online

 
 
 
 
Page 33 of 99 
ST-06153 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
ANNEX D, MEASURING INSTRUMENTS FOR TOUCH-CURRENT TESTS  
D.1 Measuring 
instrument 
 
D.2 
Alternative measuring instrument 
 
N/A 
 
ANNEX E, TEMPERATURE RISE OF A WINDING 
N/A 
 
ANNEX F, MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES 
(see 2.10) 
 
ANNEX G, ALTERNATIVE METHOD FOR DETERMINING MINIMUM 
CLEARANCES  
N/A 
G.1 
Summary of the procedure for determining 
minimum clearances 
 N/A 
G.2 
Determination of mains transient voltage (V)...... :  
N/A 
G.2.1 
AC mains supply 
 
N/A 
G.2.2 DC 
mains 
supply 
 
N/A 
G.3 
Determination of telecommunication network 
transient voltage (V)............................................ :
 N/A 
G.4 
Determination of required withstand voltage (V). :  
N/A 
G.5 
Measurement of transient levels (V) ................... :  
N/A 
G.6 
Determination of minimum clearances................ :  
N/A 
 
ANNEX H, IONIZING RADIATION (see 4.3.13) 
N/A 
 
ANNEX J, TABLE OF ELECTROCHEMICAL POTENTIALS (see 2.6.5.6) 
N/A 
 Metal 
used 
.......................................................... :  
 
 
ANNEX K, THERMAL CONTROLS (see 1.5.3 and 5.3.7) 
N/A 
K.1 
Making and breaking capacity 
 
N/A 
K.2  
Thermostat reliability; operating voltage (V) ....... :  
N/A 
K.3 
Thermostat endurance test; operating voltage 
(V)   ..................................................................... :
 N/A 
 
 
 
 
Page 34 of 99 
ST-06153 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
K.4 
Temperature limiter endurance; operating voltage 
(V) ....................................................................... :
 N/A 
K.5 
Thermal cut-out reliability 
 
N/A 
K.6 
Stability of operation 
 
N/A 
 
ANNEX L, NORMAL LOAD CONDITIONS FOR SOME TYPES OF ELECTRICAL 
BUSINESS EQUIPMENT (see 1.2.2.1 and 4.5.1) 
L.1  
Typewriters 
 
N/A 
L.2 
Adding machines and cash registers 
 
N/A 
L.3 Erasers 
 
N/A 
L.4 Pencil 
sharpeners 
 
N/A 
L.5 
Duplicators and copy machines 
 
N/A 
L.6 Motor-operated 
files 
 
N/A 
L.7 
Other business equipment 
Maximum rated output load 
 
ANNEX M, CRITERIA FOR TELEPHONE RINGING SIGNALS (see 2.3.1) 
N/A 
M.1 Introduction 
 
N/A 
M.2  
Method A 
 
N/A 
M.3 Method 
 
N/A 
M.3.1 Ringing 
signal 
 
N/A 
M.3.1.1 Frequency 
(Hz) 
.................................................. :  
 
M.3.1.2 Voltage (V)  ......................................................... :  
 
M.3.1.3 Cadence; 
time (s), voltage (V)  ........................... :  
 
M.3.1.4 Single 
fault current (mA) ..................................... :  
 
M.3.2 
Tripping device and monitoring voltage .............. :  
N/A 
M.3.2.1 
Conditions for use of a tripping device or a 
monitoring voltage 
 N/A 
M.3.2.2 Tripping 
device 
 
N/A 
M.3.2.3 Monitoring 
voltage (V)......................................... :  
N/A 
 
 
 
 
Page 35 of 99 
ST-06153 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
ANNEX N, IMPULSE TEST GENERATORS (see 2.10.3.4, 6.2.2.1, 7.3.2 and 
clause G.5) 
N/A 
N.1 
ITU-T impulse test generators 
 
N/A 
N.2 
IEC 60065 impulse test generator 
 
N/A 
 
ANNEX P, NORMATIVE REFERENCES 
 
ANNEX Q, BIBLIOGRAPHY 
 
ANNEX R, EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL 
PROGRAMMES 
N/A 
R.1 
Minimum separation distances for unpopulated 
coated printed boards (see 2.10.6) 
 N/A 
R.2 
Reduced clearances (see 2.10.3) 
 
N/A 
 
ANNEX S, PROCEDURE FOR IMPULSE TESTING (see 6.2.2.3) 
N/A 
S.1 Test 
equipment 
 
N/A 
S.2 Test 
procedure 
 
N/A 
S.3 
Examples of waveforms during impulse testing 
 
N/A 
 
ANNEX T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER 
(see 1.1.2) 
N/A 
 
Separate test report 
 
 
 
ANNEX U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED 
INSULATION (see 2.10.5.4) 
 
Separate test report 
(See appended table 1.5.1) 
 
 
ANNEX V, AC POWER DISTRIBUTION SYSTEMS (see 1.6.1) 
V.1 Introduction 
 
V.2 
TN power distribution systems 
 
V.3 
TT power distribution systems 
 
V.4 
IT power distribution systems 
Only for Norway 
 
 
 
 
Page 36 of 99 
ST-06153 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
1.5.1 
TABLE: list of critical components 
object/part No. 
manufacturer/ 
trademark 
type/model 
technical data 
standard 
mark(s) of 
conformity 
1)
 
Fuse (F1) 
Walter 
ICP 
T 1 A, 250 V, LBC
IEC 60127 
VDE 
Alt. 
Conquer 
PTU 
T 1 A, 250 V, LBC
IEC 60127 
VDE 
Alt. 
Sleek 
36ES 
T 1 A, 250 V, LBC
IEC 60127 
TÜV 
X-Capacitor 
(CX1) 
UTX HQX 
X2, max. 0.1 
µF, 
min. 275 V, 100 °C
IEC 60384-14, 
2
nd 
edition 
VDE 
Alt. Arcotronics 
R.46 
X2, max. 0.1 
µF, 
min. 275 V, 100 °C
IEC 60384-14, 
2
nd 
edition 
FI 
Alt. Okaya 
LE 
series 
X2, max. 0.1 
µF, 
min. 275 V, 100 °C
IEC 60384-14, 
2
nd 
edition 
FI 
Alt. Pilkor 
PCX2 
337M 
X2, max. 0.1 
µF, 
min. 275 V, 100 °C
IEC 60384-14, 
2
nd 
edition 
VDE 
Alt. Matsushita 
ECQUL 
X2, max. 0.1 
µF, 
min. 275 V, 100 °C
IEC 60384-14, 
2
nd 
edition 
VDE 
Alt. Carli MPX 
X2, max. 0.1 
µF, 
min. 275 V, 100 °C
IEC 60384-14, 
2
nd 
edition 
VDE 
Alt. Cheng 
Tung 
CTX 
X2, max. 0.1 
µF, 
min. 275 V, 100 °C
IEC 60384-14, 
2
nd 
edition 
FI 
Alt. Iskra 
KNB1530, 
KNB1560 
X2, max. 0.1 
µF, 
min. 275 V, 100 °C
IEC 60384-14, 
2
nd 
edition 
VDE 
Alt. Su 
Rong 
X2 
X2, max. 0.1 
µF, 
min. 275 V, 100 °C
IEC 60384-14, 
2
nd 
edition 
VDE 
Y-Capacitor 
(CY1) 
TDK 
CD 
Y1, max. 2200 pF, 
min. 250 V, 125 °C
IEC 60384-14, 
2
nd 
edition 
VDE 
Alt. 
Welson 
WD 
Y1, max. 2200 pF, 
min. 250 V, 125 °C
IEC 60384-14, 
2
nd 
edition 
VDE 
Alt. 
Jya-Nay 
JN 
Y1, max. 2200 pF, 
min. 250 V, 125 °C
IEC 60384-14, 
2
nd 
edition 
VDE 
Alt. 
Murata 
KH 
Y1, max. 2200 pF, 
min. 250 V, 125 °C
IEC 60384-14, 
2
nd 
edition 
VDE 
Alt. 
Pan Overseas 
AH 
Y1, max. 2200 pF, 
min. 250 V, 125 °C
IEC 60384-14, 
2
nd 
edition 
VDE 
Alt. Shantou 
High-
New Technology 
CD 
Y1, max. 2200 pF, 
min. 250 V, 125 °C
IEC 60384-14, 
2
nd 
edition 
VDE 
Page of 127