DOWNLOAD JBL ON CALL (serv.man2) Service Manual ↓ Size: 1.63 MB | Pages: 127 in PDF or view online for FREE

Model
ON CALL (serv.man2)
Pages
127
Size
1.63 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
on-call-sm2.pdf
Date

JBL ON CALL (serv.man2) EMC - CB Certificate ▷ View online

 
 
 
 
Page 21 of 99 
ST-06153 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
4.3 
Design and construction  
 
4.3.1 
Edges and corners 
The outer surface of the EUT is 
smoothed 
4.3.2 
Handles and manual controls; force (N) .............:
No such devices within the 
EUT 
N/A 
4.3.3 
Adjustable controls  
No such devices within the 
EUT 
N/A 
4.3.4 
Securing of parts 
The enclosures are fixed 
together by ultrasonic welding 
N/A 
4.3.5 
Connection of plugs and sockets 
No such devices within the 
EUT 
N/A 
4.3.6 
Direct plug-in equipment 
 
 
Dimensions (mm) of mains plug for direct 
plug-in    .............................................................. :
See appendixes 1-7 
 
Torque and pull test of mains plug for direct 
plug-in; torque (Nm); pull (N) .............................. :
Max. 0.07 Nm 
(See also appendixes 1-7) 
4.3.7 
Heating elements in earthed equipment 
No such devices within the 
EUT 
N/A 
4.3.8 
Batteries 
No such devices within the 
EUT 
N/A 
4.3.9 
Oil and grease 
No such materials within the 
EUT 
N/A 
4.3.10 
Dust, powders, liquids and gases 
The EUT does not produce 
such things 
N/A 
4.3.11 
Containers for liquids or gases 
No such devices within the 
EUT 
N/A 
4.3.12 Flammable 
liquids ...............................................:
No such materials within the 
EUT 
N/A 
 
Quantity of liquid (l) .............................................:
 N/A 
 
Flash point (
°C) ...................................................:  N/A 
4.3.13 Radiation; 
type 
of radiation ................................:
 
N/A 
4.3.13.1 General 
 
N/A 
4.3.13.2 
Ionizing radiation  
 
N/A 
 Measured 
radiation (pA/kg) ................................. :  
 
 Measured 
high-voltage (kV) ................................ :  
 
 
 
 
 
Page 22 of 99 
ST-06153 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
 Measured 
focus 
voltage (kV)  .............................. :  
 
 CRT 
markings 
..................................................... :  
 
4.3.13.3 
Effect of ultraviolet (UV) radiation on materials 
 
N/A 
 
Part, property, retention after test, flammability 
classification ........................................................ :
 N/A 
4.3.13.4 
Human exposure to ultraviolet (UV) radiation ..... :  
N/A 
4.3.13.5 
Laser (including LEDs) 
 
N/A 
 Laser 
class 
.......................................................... :  
 
4.3.13.6 Other 
types .......................................................... :  
N/A 
 
4.4 
Protection against hazardous moving parts 
 
4.4.1 
General 
No hazardous moving parts 
within the EUT 
N/A 
4.4.2 
Protection in operator access areas 
 
N/A 
4.4.3 
Protection in restricted access locations  
 
N/A 
4.4.4 
Protection in service access areas 
 
N/A 
 
4.5 Thermal 
requirements 
 
4.5.1 
Maximum temperatures 
(see appended table 4.5) 
 
Normal load condition per Annex L.....................: Operated in the most 
unfavourable way of operation 
given in the operating 
instructions until steady 
conditions established 
4.5.2 
Resistance to abnormal heat 
(see appended table 4.5.2) 
 
4.6 Openings 
in 
enclosures 
 
4.6.1 
Top and side openings 
 
N/A 
 Dimensions 
(mm) 
...............................................: No openings at all 
 
4.6.2 
Bottoms of fire enclosures 
 
 
Construction of the bottom.................................. : No openings at all 
 
 
 
 
 
Page 23 of 99 
ST-06153 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
4.6.3 
Doors or covers in fire enclosures 
No such devices within the 
EUT 
N/A 
4.6.4 
Openings in transportable equipment 
The EUT is direct plug-in 
equipment 
N/A 
4.6.5 
Adhesives for constructional purposes 
No barriers or screen provided 
to complying with the relevant 
requirements of sub-clause 
4.6.1, 4.6.2 or 4.6.4 
N/A 
 
Conditioning temperature (
°C)/time (weeks).......:  
 
 
4.7 
Resistance to fire 
 
4.7.1 
Reducing the risk of ignition and spread of flame
 
 
Method 1, selection and application of 
components wiring and materials 
(see appended table 4.7) 
 
Method 2, application of all of simulated fault 
condition tests 
 N/A 
4.7.2 
Conditions for a fire enclosure 
Fire enclosure is provided 
4.7.2.1 
Parts requiring a fire enclosure 
 
4.7.2.2 
Parts not requiring a fire enclosure 
 
N/A 
4.7.3 Materials 
4.7.3.1 General 
 
4.7.3.2 
Materials for fire enclosures 
(see appended table 1.5.1) 
4.7.3.3 Materials 
for 
components and other parts outside 
fire enclosures 
 N/A 
4.7.3.4 
Materials for components and other parts inside 
fire enclosures 
(see appended table 1.5.1) 
4.7.3.5 
Materials for air filter assemblies 
No such devices within the 
EUT 
N/A 
4.7.3.6 
Materials used in high-voltage components 
No such devices within the 
EUT 
N/A 
 
 
 
 
 
Page 24 of 99 
ST-06153 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS 
 
 
5.1 
Touch current and protective conductor current 
 
5.1.1 General 
 
5.1.2 
Equipment under test (EUT) 
 
5.1.3 
Test circuit 
Test circuit as in figure 5A is 
used 
5.1.4 
Application of measuring instrument 
Measuring instrument as in 
annex D.1 is used  
5.1.5 Test 
procedure 
 
5.1.6 Test 
measurements 
 
 Test 
voltage (V) ..................................................:
Input voltage: 264 Vac, 60 Hz 
 
 
Measured touch current (mA)  ............................:
U2 / 500 = 0.17 mA 
 
 Max. 
allowed 
touch current (mA)  .......................:
0.25 mA 
 
 
Measured protective conductor current (mA)  ....:
 
 
 
Max. allowed protective conductor current (mA) :
 
 
5.1.7 
Equipment with touch current exceeding 
3.5 mA   ..............................................................:
No such equipment 
N/A 
5.1.8 
Touch currents to and from telecommunication 
networks and cable distribution systems and from 
telecommunication networks 
No TNV circuit within the EUT 
N/A 
5.1.8.1 
Limitation of the touch current to a 
telecommunication network and a cable 
distribution system 
No TNV circuit within the EUT 
N/A 
 Test 
voltage (V) ..................................................:
 
 
 
Measured touch current (mA)  ............................:
 
 
 Max. 
allowed 
touch current (mA)  .......................:
 
 
5.1.8.2 
Summation of touch currents from 
telecommunication networks.............................. :
No TNV circuit within the EUT 
N/A 
 
5.2 Electric 
strength 
 
5.2.1 
General 
(see appended table 5.2)  
5.2.2 
Test procedure  
(see appended table 5.2)  
Page of 127
Display