JBL ON CALL (serv.man2) EMC - CB Certificate ▷ View online
Page 41 of 99
ST-06153
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
1.6.2
TABLE: electrical data (in normal conditions)
P
fuse # Irated
(A)
U (V)
P (W)
I (mA)
Ifuse (mA)
condition/status
Tested on model: MU15-C033280-C5
F1
—
90 V (50 /60 Hz)
12.7 / 12.6
248 / 255
248 / 255
Maximum rated output load
F1
0.5
100 V (50 /60 Hz)
12.6 / 12.6
230 / 238
230 / 238
Maximum rated output load
F1
0.5
240 V (50 /60 Hz)
13.0 / 13.0
131 / 127
131 / 127
Maximum rated output load
F1
—
254.4 V (50 /60 Hz) 13.1 / 13.1
126 / 122
126 / 122
Maximum rated output load
F1
—
264 V (50 /60 Hz)
13.2 / 13.1
122 / 119
122 / 119
Maximum rated output load
Tested on model: MU15-C060250-C5
F1
—
90 V (50 /60 Hz)
19.0 / 19.0
352 / 358
352 / 358
Maximum rated output load
F1
0.5
100 V (50 /60 Hz)
18.9 / 18.9
324 / 332
324 / 332
Maximum rated output load
F1
0.5
240 V (50 /60 Hz)
19.1 / 19.2
181 / 180
181 / 180
Maximum rated output load
F1
—
254.4 V (50 /60 Hz) 19.2 / 19.2
175 / 175
175 / 175
Maximum rated output load
F1
—
264 V (50 /60 Hz)
19.4 / 19.4
172 / 170
172 / 170
Maximum rated output load
Tested on model: MU15-C240010-C5
F1
—
90 V (50 /60 Hz)
3.5 / 3.5
84 / 83
84 / 83
Maximum rated output load
F1
0.5
100 V (50 /60 Hz)
3.5 / 3.5
77 / 76
77 / 76
Maximum rated output load
F1
0.5
240 V (50 /60 Hz)
3.9 / 3.8
41 / 41
41 / 41
Maximum rated output load
F1
—
254.4 V (50 /60 Hz)
3.9 / 3.9
40 / 39
40 / 39
Maximum rated output load
F1
—
264 V (50 /60 Hz)
4.0 / 4.0
39 / 39
39 / 39
Maximum rated output load
Page 42 of 99
ST-06153
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
2.1.1.5
TABLE: energy hazards measurements
P
Measured
between
Max. V (Uoc) Max. A (Isc)
V of Max.
power
A of Max.
power
Max. power
Bridged by
test finger
Tested on model: MU15-C033280-C5
Output
3.48 Vdc
4.15 A
2.77 Vdc
4.15 A
11.5 VA
No
Tested on model: MU15-C060250-C5
Output
6.05 Vdc
4.17 A
5.42 Vdc
4.17 A
22.6 VA
No
Tested on model: MU15-C240010-C5
Output
24.04 Vdc
1.83 A
23.71 Vdc
1.83 A
43.4 VA
No
Page 43 of 99
ST-06153
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
2.10.3 and
2.10.4
2.10.4
TABLE: clearance and creepage distance measurements
P
clearance cl and creepage
distance dcr at/of:
distance dcr at/of:
Up
(V)
U r.m.s.
(V)
required cl
(mm)
cl
(mm)
required
dcr (mm)
dcr
(mm)
On PCB component side:
Line and Neutral before and
after current fuse (F1) (FI)
after current fuse (F1) (FI)
340 240 1.5 2.9 2.5 2.9
Two ends of current fuse (F1)
(FI)
(FI)
340 240 1.5 2.9 2.5 2.9
Primary and secondary (two
sides of U2) (RI)
sides of U2) (RI)
352 240 4.0 7.0 5.0 7.0
Primary components to user
accessible parts
accessible parts
2)
(RI)
340 240 4.0 6.0 5.0 6.5
Primary and secondary (two
sides of CY1) (RI)
sides of CY1) (RI)
340 240 4.0 7.5 5.0 7.5
On PCB solder side:
Line and Neutral before and
after current fuse (F1) (FI)
after current fuse (F1) (FI)
340 240 1.5 3.1 2.5 3.1
Two ends of current fuse (F1)
(FI)
(FI)
340 240 1.5 3.1 2.5 3.1
Primary and secondary (two
sides of U2) (RI)
sides of U2) (RI)
352 240 4.0 5.1 5.0 5.1
Primary and secondary (two
sides of CY1) (RI)
sides of CY1) (RI)
340 240 4.0 5.4 5.0 5.4
Piug pins / primary traces /
leads to user accessible parts
leads to user accessible parts
2)
(RI)
340 240 4.0 6.0 5.0 6.5
Page 44 of 99
ST-06153
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
2.10.3 and
2.10.4
(cont.)
2.10.4
(cont.)
TABLE: clearance and creepage distance measurements
P
clearance cl and creepage
distance dcr at/of:
distance dcr at/of:
Up
(V)
U r.m.s.
(V)
required cl
(mm)
cl
(mm)
required
dcr (mm)
dcr
(mm)
Transformer (T1):
Primary traces to secondary
traces on PCB solder side
(RI)
traces on PCB solder side
(RI)
480 242 4.2 5.5 5.0 5.5
Primary winding to secondary
winding (RI)
winding (RI)
480 242 4.2 8.0 5.0 8.0
Secondary winding to core
3)
(RI)
480 242 4.2 8.0 5.0 8.0
Secondary components
2)
to
core
3)
(RI)
480 242 4.2 6.0 5.0 6.0
Note:
1) FI: Functional insulation; BI: Basic insulation; SI: Supplementary insulation; RI: Reinforced insulation.
2) A force of 10 N is applied to the internal components and 30 N is applied to the enclosure for
measuring.
3) The core of transformer (T1) is considered as primary winding. The TIW is used as secondary winding
of (T1).
4) The distances are measured along the insulating tape around secondary heatsink.
2.10.5
TABLE: distance through insulation measurements
P
distance through insulation di at/of:
Up
(V)
(V)
test voltage
(V)
required di
(mm)
di
(mm)
Optocoupler (U2) (RI)
340
3000 Vac
0.4
0.4
Enclosure (RI)
340
3000 Vac
0.4 Min.
2.3
Insulating tube (BI)
340
1500 Vac
--
--
Insulating sheet
340
1500 Vac
--
--
thin sheet material at/of:
Up
(V)
(V)
test voltage
(V)
required
layer(s)
layer(s)
Insulating tape around the outer side
2)
of
transformer (T1) (RI)
540
3000 Vac / 2
layers
3 3
Note:
1) FI: Functional insulation; BI: Basic insulation; SI: Supplementary insulation; RI: Reinforced insulation.
2) The core of transformer (T1) is considered as primary winding.