DOWNLOAD JBL ON CALL (serv.man2) Service Manual ↓ Size: 1.63 MB | Pages: 127 in PDF or view online for FREE

Model
ON CALL (serv.man2)
Pages
127
Size
1.63 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
on-call-sm2.pdf
Date

JBL ON CALL (serv.man2) EMC - CB Certificate ▷ View online

 
 
 
 
Page 2 of 99                                                             ST-06153 
 
TRF No.: IECEN60950_1A 
 
 
 
Particulars: test item vs. test requirements 
Equipment mobility  ..................................... : Direct plug-in 
Operating condition ..................................... : Continuous  
Mains supply tolerance (%) ......................... : + 6 %, + 10 % and – 10 % (the test voltage + 10 % is 
required by the manufacturer) 
Tested for IT power systems  ...................... : Yes  
IT testing, phase-phase voltage (V)  ........... : 230 V for Norway 
Class of equipment ..................................... : Class II  
Mass of equipment (kg) ............................... : Max. 0.11 kg 
Protection against ingress of water  ............ : IP20 
Test case verdicts 
 
Test case does not apply to the test object  : N/A (Not Applicable) 
Test item does meet the requirement ......... : P (Pass) 
Test item does not meet the requirement ... : F (Fail) 
Testing 
 
Date of receipt of test item .......................... : May 12, 2006 
Date(s) of performance of test .................... : May 12, 2006 – May 17, 2006 
General remarks 
“This report is not valid as a CB Test Report unless appended by an approved CB Testing 
Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02”.
The test result presented in this report relate only to the object(s) tested. 
This report shall not be reproduced, except in full, without the written approval of the Issuing testing 
laboratory. 
“(see Appendix #)” refers to additional information appended to the report.  
“(see appended table #)” refers to a table appended to the report. 
Throughout this report a comma (point) is used as the decimal separator. 
Additional information 
Additional special deviations of CN (China) of IEC 60950, 3rd ed. are checked. 
 
 
 
 
Page 3 of 99                                                             ST-06153 
 
TRF No.: IECEN60950_1A 
 
 
 
Copy of marking plate and summary of test results (information/comments): 
(Representative) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
I.T.E. POWER SUPPLY 
Model No.: MU15-C033280-C5 
Input: 100-240 V
 50/60 Hz 0.5 A 
Output: 3.3 V
  2.8 A 
        
    
  
    
LEI 
 
 
I.T.E. POWER SUPPLY 
Model No.: MU15-C060250-C5 
Input: 100-240 V
 50/60 Hz 0.5 A 
Output: 6 V
  2.5 A 
        
    
  
    
LEI 
 
 
I.T.E. POWER SUPPLY 
Model No.: MU15-C240010-C5 
Input: 100-240 V
 50/60 Hz 0.5 A 
Output: 24 V
  0.1 A 
        
    
  
    
LEI 
 
 
I.T.E. POWER SUPPLY 
Model No.: MU15-C033280-C5 
Input: 100-240 V
 50/60 Hz 0.5 A 
Output: 3.3 V
  2.8 A 
        
    
  
    
LEI 
 
I.T.E. POWER SUPPLY 
Model No.: MU15-C060250-C5 
Input: 100-240 V
 50/60 Hz 0.5 A 
Output: 6 V
  2.5 A 
        
    
  
    
LEI 
 
I.T.E. POWER SUPPLY 
Model No.: MU15-C240010-C5 
Input: 100-240 V
 50/60 Hz 0.5 A 
Output: 24 V
  0.1 A 
        
    
  
    
LEI 
 
 
 
 
Page 4 of 99                                                             ST-06153 
 
TRF No.: IECEN60950_1A 
 
 
 
Summary of testing: 
1.6.2                      Input current test 
1.7.13                    Marking durability test 
2.1.1.1 b                Finger test 
2.1.1.1 c                Pin test 
2.1.1.5                   Energy hazards test 
2.1.1.7                   Stored Discharge on capacitor test 
2.2.2                      Voltages under normal conditions test 
2.2.3                      Voltages under fault conditions test 
2.4                         Limited current circuits test 
2.5                         Limited power sources test 
2.9.2                      Humidity conditioning test 
2.10.2                    Determination of working voltage test 
2.10.3, 2.10.4        Clearances and creepage distances measurements 
2.10.5                    Distance through insulation measurements 
4.2.2                      Mechanical strength – steady force test, 10 N 
4.2.4                      Mechanical strength – steady force test, 250 N 
4.2.6                      Mechanical strength – drop test 
4.2.7                      Mechanical strength – stress relief test 
4.3.6                      Strain on socket-outlet test (for direct plug-in equipment) 
4.5.1                      Normal operating test 
4.5.2                      Ball pressure test 
5.1                         Touch current test 
5.2                         Electric strength test 
5.3                         Abnormal operating and fault conditions test 
 
General product information: 
Explanation of model designation of MU15-C******-**: 
The 1
st
 to 3
rd
 “*” denotes the output voltage, which can be “033” (3.3 Vdc) to “240” (24 Vdc). 
The 4
th
 to 6
th
 “*” denotes the output current, which can be “010” (0.1 A) to “280” (2.8 A). 
The 7
th
 to 8
th
 “*” denotes the type of plug, which can be “A1”, “A2”, “A3”, “A4”, “B2”, “C4” or “C5” (“A1” 
comply with ANSI/UL 1310 and ANSI/UL 1681, “A2” comply with GB 1002-1996, “A3” comply with 
AS/NZS 3112: 2004, “A4” comply with IRAM 2063, “B2” comply with BS 1363, “C4” comply with KSC 
8305, and “C5” comply with EN 50075 and IEC 60884-1). 
 
Page of 127
Display

JBL ON CALL (serv.man2) EMC - CB Certificate ▷ Download

  • DOWNLOAD JBL ON CALL (serv.man2) Service Manual ↓ Size: 1.63 MB | Pages: 127 in PDF or view online for FREE
  • Here you can View online or download the EMC - CB Certificate for the JBL ON CALL (serv.man2) in PDF for free, which will help you to disassemble, recover, fix and repair JBL ON CALL (serv.man2) Audio. Information contained in JBL ON CALL (serv.man2) EMC - CB Certificate (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.