JBL ON CALL (serv.man2) EMC - CB Certificate ▷ View online

 
 
 
 
Page 57 of 99 
ST-06153 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
 
TRF No.: IECEN60950_1A 
 
 
5.3 (cont.)  TABLE: fault condition tests 
 
ambient temperature (
°C) ....................................: 25 
 
 
model/type of power supply .................................: See page 1 
 
 
manufacturer of power supply  .............................: See page 1 
 
 
rated markings of power supply  ..........................: See page 1 
 
No. 
component  
No. 
fault
test voltage 
 (V) 
test time 
fuse
No. 
fuse current 
(A) 
result 
D7 S 264 10 
min. 
F1 0.01 
Observation: Unit shut down. No 
hazards. 
Damage: 
 
Temp: 
 
Max. Voltage: 
 
10 
C5 S 264 10 
min. 
F1 0.01 
Observation: Unit shut down. No 
hazards. 
Damage: 
 
Temp: 
 
Max. Voltage: 
 
11 
U2 (pin 1-2) 
264 
10 min. 
F1 
0.01 
Observation: Unit shut down. No 
hazards. 
Damage: 
 
Temp: 
 
Max. Voltage: 
 
12 
U2 Pin 1 
264 
10 min. 
F1 
0.01 
Observation: Unit shut down. No 
hazards. 
Damage: 
 
Temp: 
 
Max. Voltage: 
 
13 
U2 (pin 3-4) 
264 
10 min. 
F1 
0.01 
Observation: Unit shut down. No 
hazards. 
Damage: 
 
Temp: 
 
Max. Voltage: 
 
14 
U2 Pin 4 
264 
10 min. 
F1 
0.01 
Observation: Unit shut down. No 
hazards. 
Damage: 
 
Temp: 
 
Max. Voltage: 
 
15 
T1 (A-B) 
264 
10 min. 
F1 
0.01 
Observation: Unit shut down. No 
hazards. 
Damage: 
 
Temp: 
 
Max. Voltage: 
 
16 
T1 (A-B) 
O/L 
264 
5.5 hr. 
F1 
0.255 
Observation: Loaded to 3.7 A 
then Unit shut down. No hazards.
Damage: 
 
Temp: 145.7 
°C 
Max. Voltage: 5.7 Vdc
 
17 
T1 (pin 3-4) 
264 
10 min. 
F1 
0.08 
Observation: Unit shut down. No 
hazards. 
Damage: 
 
Temp: 
 
Max. Voltage: 
 
 
 
 
 
Page 58 of 99 
ST-06153 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
5.3 (cont.)  TABLE: fault condition tests 
 
ambient temperature (
°C) ....................................: 25 
 
 
model/type of power supply .................................: See page 1 
 
 
manufacturer of power supply  .............................: See page 1 
 
 
rated markings of power supply  ..........................: See page 1 
 
No. 
component  
No. 
fault
test voltage 
 (V) 
test time 
fuse
No. 
fuse current 
(A) 
result 
18 
Output 
terminal
 
O/L 264  6.5 
hr. 
F1  0.257 
Observation: Loaded to 3.7 A 
then Unit shut down. No hazards.
Damage: 
 
Temp: 139 
°C 
Max. Voltage: 5.14 V
 
19 
Output 
terminal
 
S 264 10 
min. 
F1 0.04 
Observation: Unit shut down. No 
hazards. 
Damage: 
 
Temp: 
 
Max. Voltage: 
 
Tested on model: MU15-C240010-C5 
D1 
264 
< 1 s 
F1 
> 2.1 
Observation: F1 opened 
Damage: 
 
Temp: 
 
Max. Voltage: 
 
C1 
264 
< 1 s 
F1 
> 2.1 
Observation: Unit shut down. No 
hazards. 
Damage: 
 
Temp: 
 
Max. Voltage: 
 
Q1 (D-S) 
264 
< 1 s 
F1 
> 2.1 
Observation: F1 opened 
Damage: R1, R8, Q1, U1 
Temp: 
 
Max. Voltage: 
 
Q1 (D-G) 
264 
< 1 s 
F1 
> 2.1 
Observation: F1 opened 
Damage: R8, Q1, U1 
Temp: 
 
Max. Voltage: 
 
U1 (pin 2-5) 
264 
10 min. 
F1 
0.01 
Observation: Unit shut down. No 
hazards. 
Damage: 
 
Temp: 
 
Max. Voltage: 
 
U1 (pin 4-5) 
264 
10 min. 
F1 
0.01 
Observation: Unit shut down. No 
hazards. 
Damage: 
 
Temp: 
 
Max. Voltage: 
 
U1 (pin 2-3) 
264 
10 min. 
F1 
0.01 
Observation: Unit shut down. No 
hazards. 
Damage: 
 
Temp: 
 
Max. Voltage: 
 
 
 
 
 
Page 59 of 99 
ST-06153 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
5.3 (cont.)  TABLE: fault condition tests 
 
ambient temperature (
°C) ....................................: 25 
 
 
model/type of power supply .................................: See page 1 
 
 
manufacturer of power supply  .............................: See page 1 
 
 
rated markings of power supply  ..........................: See page 1 
 
No. 
component  
No. 
fault
test voltage 
 (V) 
test time 
fuse
No. 
fuse current 
(A) 
result 
R1 
264 
1 s 
F1 
> 2.1 
Observation: F1 opened 
Damage: Q1, U1 
Temp: 
 
Max. Voltage: 
 
D7 S 264 10 
min. 
F1 0.01 
Observation: Unit shut down. No 
hazards. 
Damage: 
 
Temp: 
 
Max. Voltage: 
 
10 
C5 S 264 10 
min. 
F1 0.01 
Observation: Unit shut down. No 
hazards. 
Damage: 
 
Temp: 
 
Max. Voltage: 
 
11 
U2 (pin 1-2) 
264 
10 min. 
F1 
0.01 
Observation: Unit shut down. No 
hazards. 
Damage: 
 
Temp: 
 
Max. Voltage: 
 
12 
U2 Pin 1 
264 
10 min. 
F1 
0.01 
Observation: Unit shut down. No 
hazards. 
Damage: 
 
Temp: 
 
Max. Voltage: 
 
13 
U2 (pin 3-4) 
264 
10 min. 
F1 
0.01 
Observation: Unit shut down. No 
hazards. 
Damage: 
 
Temp: 
 
Max. Voltage: 
 
14 
U2 Pin 4 
264 
10 min. 
F1 
0.01 
Observation: Unit shut down. No 
hazards. 
Damage: 
 
Temp: 
 
Max. Voltage: 
 
15 
T1 (A-B) 
264 
10 min. 
F1 
0.01 
Observation: Unit shut down. No 
hazards. 
Damage: 
 
Temp: 
 
Max. Voltage: 
 
16 
T1 (A-B) 
O/L 
264 
4.5 hr. 
F1 
0.244 
Observation: Loaded to 0.9 A 
then Unit shut down. No hazards.
Damage: 
 
Temp: 151 
°C 
Max. Voltage: 23.5 Vdc
 
 
 
 
 
Page 60 of 99 
ST-06153 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
 
TRF No.: IECEN60950_1A 
 
 
17 
T1 (pin 3-4) 
264 
10 min. 
F1 
0.08 
Observation: Unit shut down. No 
hazards. 
Damage: 
 
Temp: 
 
Max. Voltage: 
 
18 
Output 
terminal
 
O/L 264  4.2 
hr. 
F1  0.253 
Observation: Loaded to 1 A then 
Unit shut down. No hazards. 
Damage: 
 
Temp: 161 
°C 
Max. Voltage: 5.14 Vdc
 
19 
Output 
terminal
 
S 264 10 
min. 
F1 0.04 
Observation: Unit shut down. No 
hazards. 
Damage: 
 
Temp: 
 
Max. Voltage: 
 
supplementary information 
Note: 
1)  S: Short-circuited; O: Open-circuited; O/L: Overloaded; B: Blocked; L: Locked. 
2)  Observation: The observations during and after fault condition tests. 
3)  Damag: Which component (components) damaged during the fault condition test. 
4)  Temp: The maximum temperature of transformer (T1) winding. 
5)  Max. Voltage: The maximum accessible voltage of DC output terminal during the fault condition test. 