DOWNLOAD JBL ON CALL (serv.man2) Service Manual ↓ Size: 1.63 MB | Pages: 127 in PDF or view online for FREE

Model
ON CALL (serv.man2)
Pages
127
Size
1.63 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
on-call-sm2.pdf
Date

JBL ON CALL (serv.man2) EMC - CB Certificate ▷ View online

 
 
 
 
Page 61 of 99 
ST-06153 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
 
 
IEC 60950-1, 1st ed.  
(EN 60950-1: 2001 + A11: 2004) 
 
GROUP DIFFERENCES, NATIONAL DEVIATIONS AND SPECIAL NATIONAL CONDITIONS IN THE 
CENELEC COUNTRIES 
 
C = CENELEC COMMON MODIFICATIONS  
S = SPECIAL NATIONAL CONDITIONS  
A = A-DEVIATIONS (NATIONAL DEVIATIONS)                                                                    
 
 
C: Delete all the "country" notes in the reference 
document according to the following list: 
1.1.5  
Note 2 
1.5.8 
Note 2 
1.6.1  Note  
1.7.2 
Note 4 
1.7.12 
Note 2 
2.6 
Note 
2.2.3 
Note 
2.2.4 
Note 
2.3.2  Note 2, 7, 8
2.3.3 
Note 1, 2  2.3.4 
Note 2,3  2.7.1  Note 
2.10.3.1 Note 4 
3.2.1.1  Note 
3.2.3  Note 1, 2 
3.2.5.1  Note 2 
4.3.6 
Note 1,2  4.7.2.2  Note 
4.7.3.1 Note 
6.1.2.1  Note 
6.1.2.2 Note 
6.2.2 Note 
6.2.2.1 Note 
2 6.2.2.2 
Note 
7 Note 
7.1 Note 
 
G2.1 
Note 1, 2  Annex H  Note 2 
Considered P 
1.2.4.1 
S (DK): In Denmark, certain types of Class I 
appliances (see 3.2.1.1) may be provided with a 
plug not establishing earthing conditions when 
inserted into Danish socket-outlets. 
Class II equipment 
N/A 
1.5.1 
A (CH): The following is added: 
Switzerland (Ordinance on environmentally 
hazardous substances SR 814.013, Annex 3.2, 
Mercury):  
NOTE- In Switzerland, switches containing 
mercury such as thermostats, relays and level 
controllers are not allowed. 
No such devices within the 
EUT 
N/A 
 
A (SE): The following is added: 
Sweden (Ordinance (1990:944) 
NOTE- In Sweden, switches containing mercury 
such as thermostats, relays and level controllers 
are not allowed. 
No such devices within the 
EUT 
N/A 
 
 
 
 
Page 62 of 99 
ST-06153 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
 
TRF No.: IECEN60950_1A 
 
 
1.5.8 
S (NO): In Norway, due to the IT power system 
used (see annex V, Fig. V.7), capacitors are 
required to be rated for the applicable line-to-line 
voltage (230 V). 
 N/A 
1.7.2 A 
(DK): 
Denmark (Heavy Current Regulations) 
Supply cords of CLASS I EQUIPMENT, which is 
delivered without a plug, must be provided with a 
visible tag with the following text: 
Vigtigt! 
Lederen med grøn/gul isolation må kun tilsluttes 
en klemme mærket 
 
 eller  
  
If essential for the safety of the equipment, the 
tag must in addition be provided with a diagram 
which shows the connection of the other 
conductors, or be provided with the following text: 
"For tilslutning af de øvrige ledere, se 
medfølgende instalationsvejledning." 
Class II equipment 
N/A 
 
S (FI): In Finland, CLASS I PLUGGABLE 
EQUIPMENT TYPE A intended for connection to 
other equipment or a network shall, if safety 
relies on connection to protective earth or if surge 
suppressors are connected between the network 
terminals and accessible parts, have a marking 
stating that the equipment must be connected to 
an earthed mains socket-outlet. 
The marking text in the applicable countries shall 
be as follows: 
"Laite on liitettävä suojamaadoituskoskettimilla 
varustettuun pistorasiaan" 
 N/A 
 
 
 
 
S (NO): In Norway, CLASS I PLUGGABLE 
EQUIPMENT TYPE A intended for connection to 
other equipment or a network shall, if safety 
relies on connection to protective earth or if surge 
suppressors are connected between the network 
terminals and accessible parts, have a marking 
stating that the equipment must be connected to 
an earthed mains socket-outlet. 
The marking text in the applicable countries shall 
be as follows: 
"Apparatet må tilkoples jordet stikkontakt" 
 N/A 
 
 
 
 
Page 63 of 99 
ST-06153 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
 
TRF No.: IECEN60950_1A 
 
 
 
S (SE): The following is added: 
In Sweden, CLASS I PLUGGABLE EQUIPMENT 
TYPE A intended for connection to other 
equipment or a network shall, if safety relies on 
connection to protective earth or if surge 
suppressors are connected between the network 
terminals and accessible parts, have a marking 
stating that the equipment must be connected to 
an earthed mains socket-outlet. 
The marking text in the applicable countries shall 
be as follows: 
"Apparaten skall anslutas till jordat uttag" 
 N/A 
1.7.5 A 
(DK): 
Denmark (Heavy Current Regulations) 
CLASS II EQUIPMENT shall not be fitted with 
socket-outlets for providing power to other 
equipment. 
 N/A 
 
 
 
S (DK): In Denmark, socket-outlets for providing 
power to other equipment shall be in accordance 
with the Heavy Current Regulations, Section 107-
2-D1, Standard Sheet DK 1-3a, DK 1-5a or DK 1-
7a, when used on Class I equipment. For 
STATIONARY EQUIPMENT the socket-outlet 
shall be in accordance with Standard Sheet DK 
1-1b or DK 1-5a. 
 N/A 
1.7.12 A 
(DE): 
Germany (Gesetz über techische 
Arbeitsmittel (Gerätesicherheitsgesetz) [Law on 
technical labour equipment {Equipment safety 
law}], of 23
rd
 October 1992, Article 3, 3
rd
 
paragraph, 2
nd
 sentence, together with the 
"Allgemeine Verwaltungsvorschrift zur 
Durchführung des Zweiten Abschnitts des 
Gerätesicherheitsgesetzes" [General 
administrative regulation on the execution of the 
Second Section of the Equipment safety law], of 
10
th
 January 1996, article 2, 4
th
 paragraph, item 
2). 
Directions for use with rules to prevent certain 
hazards for (among others) maintenance of the 
technical labour equipment, also for imported 
technical labour equipment shall be written in the 
German language. 
NOTE Of this requirement, rules for use even 
only by service personnel are not exempted.  
 P 
 
 
 
 
Page 64 of 99 
ST-06153 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
 
TRF No.: IECEN60950_1A 
 
 
1.7.15 A 
(CH): 
Switzerland (Ordinance on 
environmentally hazardous substances SR 
814.013): 
Annex 4.10 of SR 814.013 applies for batteries. 
No battery used in the EUT 
N/A 
2.2.4 
S (NO): In Norway, requirements according to 
this annex, 1.7.2 and 6.1.2.1 apply. 
 N/A 
2.3.2 
S (NO): In Norway, requirements according to 
this annex, 6.1.2.1 apply. 
 N/A 
2.3.3  
S (NO): In Norway, requirements according to 
this annex, 1.7.2 and 6.1.2.1 apply. 
 N/A 
2.3.4 
S (NO): In Norway, requirements according to 
this annex, 1.7.2 and 6.1.2.1 apply. 
 N/A 
2.6.3.3 
S (GB): In the United Kingdom, the current 
rating of the circuit shall be taken as 13 A, not 16 
A. 
 N/A 
Page of 127