ST-06153
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
2.7.1 C:
Replace the subclause as follows:
Basic requirements
To protect against excessive current, short-
circuits and earth faults in PRIMARY CIRCUITS,
protective devices shall be included either as
integral parts of the equipment or as parts of the
building installation, subject to the following, a),
b) and c):
circuits and earth faults in PRIMARY CIRCUITS,
protective devices shall be included either as
integral parts of the equipment or as parts of the
building installation, subject to the following, a),
b) and c):
a) except as detailed in b) and c), protective
devices necessary to comply with the
requirements of 5.3 shall be included as
parts of the equipment;
requirements of 5.3 shall be included as
parts of the equipment;
b) for components in series with the mains input
to the equipment such as the supply cord,
appliance coupler, r.f.i. filter and switch,
short-circuit and earth fault protection may be
provided by protective devices in the building
installation;
appliance coupler, r.f.i. filter and switch,
short-circuit and earth fault protection may be
provided by protective devices in the building
installation;
c) it is permitted for PLUGGABLE EQUIPMENT
TYPE B or PERMANENTLY CONNECTED
EQUIPMENT, to rely on dedicated
overcurrent and short-circuit protection in the
building installation, provided that the means
of protection, e.g. fuses or circuit breakers, is
fully specified in the installation instructions.
EQUIPMENT, to rely on dedicated
overcurrent and short-circuit protection in the
building installation, provided that the means
of protection, e.g. fuses or circuit breakers, is
fully specified in the installation instructions.
If reliance is placed on protection in the building
installation, the installation instructions shall so
state, except that for PLUGGABLE EQUIPMENT
TYPE A the building installation shall be
regarded as providing protection in accordance
with the rating of the wall socket outlet.
installation, the installation instructions shall so
state, except that for PLUGGABLE EQUIPMENT
TYPE A the building installation shall be
regarded as providing protection in accordance
with the rating of the wall socket outlet.
Considered P
S (GB): In the United Kingdom, to protect
against excessive currents and short-circuits in
the PRIMARY CIRCUIT OF DIRECT PLUG-IN
EQUIPMENT, protective device shall be included
as integral parts of the DIRECT PLUG-IN
EQUIPMENT.
against excessive currents and short-circuits in
the PRIMARY CIRCUIT OF DIRECT PLUG-IN
EQUIPMENT, protective device shall be included
as integral parts of the DIRECT PLUG-IN
EQUIPMENT.
P
2.7.2
C: This subclause has been declared 'void'.
N/A
2.10.2 C:
Replace in the first line "(see also 1.4.7)" by
"(see also 1.4.8)".
P
Page 66 of 99
ST-06153
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
2.10.3.1
S (NO): In Norway, due to the IT power
distribution system used (see annex V, Fig. V.7),
the
distribution system used (see annex V, Fig. V.7),
the
A
.
C
.
MAINS SUPPLY
voltage is considered to
be equal to the line-to-line voltage and will
remain at 230 V in case of a single earth fault.
remain at 230 V in case of a single earth fault.
P
3.2.1.1
S (CH): In Switzerland, supply cords of
equipment having a
equipment having a
RATED CURRENT
not
exceeding 10 A shall be provided with a plug
complying with SEV 1011 or IEC 60884-1 and
one of the following dimension sheets:
complying with SEV 1011 or IEC 60884-1 and
one of the following dimension sheets:
SEV 6532-2.1991, Plug type 15, 3P+N+PE 250/400 V, 10 A
SEV 6533-2.1991, Plug type 11, L+N
SEV 6533-2.1991, Plug type 11, L+N
250 V, 10 A
SEV 6534-2.1991, Plug type 12, L+N+PE
250 V, 10 A
In general, EN 60309 applies for plugs for
currents exceeding 10A. However, a 16 A plug
and socket-outlet system is being introduced in
Switzerland, the plugs of which are according to
the following dimension sheets, published in
February 1998:
currents exceeding 10A. However, a 16 A plug
and socket-outlet system is being introduced in
Switzerland, the plugs of which are according to
the following dimension sheets, published in
February 1998:
SEV 5932-2.1998, Plug type 25, 3L+N+PE 230/400 V, 16 A
SEV 5933-2.1998, Plug type 21, L+N
SEV 5933-2.1998, Plug type 21, L+N
250 V, 16 A
SEV 5934-2.1998, Plug type 23, L+N+PE
250 V, 16 A
Direct plug-in equipment
N/A
S
(DK): In Denmark, supply cords of single-
phase equipment having a rated current not
exceeding 13 A shall be provided with a plug
according to the Heavy Current
Regulations,Section 107-2-D1.
exceeding 13 A shall be provided with a plug
according to the Heavy Current
Regulations,Section 107-2-D1.
CLASS I EQUIPMENT provided with socket-
outlets with earth contacts or which are intended
to be used in locations where protection against
indirect contact is required according to the
wiring rules shall be provided with a plug in
accordance with standard sheet DK 2-1a or DK
2-5a.
outlets with earth contacts or which are intended
to be used in locations where protection against
indirect contact is required according to the
wiring rules shall be provided with a plug in
accordance with standard sheet DK 2-1a or DK
2-5a.
If poly-phase equipment and single-phase
equipment having a RATED CURRENT
exceeding 13 A is provided with a supply cord
with a plug, this plug shall be in accordance with
the Heavy Current Regulations, Section 107-2-
D1 or EN 60309-2.
equipment having a RATED CURRENT
exceeding 13 A is provided with a supply cord
with a plug, this plug shall be in accordance with
the Heavy Current Regulations, Section 107-2-
D1 or EN 60309-2.
N/A
Page 67 of 99
ST-06153
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
S (ES): In Spain, supply cords of single-phase
equipment having a rated current not exceeding
10 A shall be provided with a plug according to
UNE 20315:1994.
equipment having a rated current not exceeding
10 A shall be provided with a plug according to
UNE 20315:1994.
Supply cords of single-phase equipment having a
rated current not exceeding 2,5 A shall be
provided with a plug according to
UNE-EN 50075:1993.
rated current not exceeding 2,5 A shall be
provided with a plug according to
UNE-EN 50075:1993.
CLASS I EQUIPMENT provided with socket-
outlets with earth contacts or which are intended
to be used in locations where protection against
indirect contact is required according to the
wiring rules, shall be provided with a plug in
accordance with standard UNE 20315:1994.
outlets with earth contacts or which are intended
to be used in locations where protection against
indirect contact is required according to the
wiring rules, shall be provided with a plug in
accordance with standard UNE 20315:1994.
If poly-phase equipment is provided with a supply
cord with a plug, this plug shall be in accordance
with UNE-EN 60309-2.
cord with a plug, this plug shall be in accordance
with UNE-EN 60309-2.
N/A
S (GB): In the United Kingdom, apparatus
which is fitted with a flexible cable or cord and is
designed to be connected to a mains socket
conforming to BS 1363 by means of that flexible
cable or cord and plug, shall be fitted with a
'standard plug' in accordance with Statutory
Instrument 1768:1994 – The Plugs and Socket
etc. (Safety) Regulations 1994, unless exempted
by those regulations.
which is fitted with a flexible cable or cord and is
designed to be connected to a mains socket
conforming to BS 1363 by means of that flexible
cable or cord and plug, shall be fitted with a
'standard plug' in accordance with Statutory
Instrument 1768:1994 – The Plugs and Socket
etc. (Safety) Regulations 1994, unless exempted
by those regulations.
NOTE – 'Standard plug' is defined in
SI 1768:1994 and essentially means an
approved plug conforming to BS 1363 or an
approved conversion plug.
SI 1768:1994 and essentially means an
approved plug conforming to BS 1363 or an
approved conversion plug.
N/A
S (IE): In Ireland, apparatus which is fitted with a
flexible cable or cord and is designed to be
connected to a mains socket conforming to I.S.
411 by means of that flexible cable or cord and
plug, shall be fitted with a 13 A plug in
accordance with Statutory Instrument 525:1997 –
National Standards Authority of Ireland (section
28) (13 A Plugs and Conversion Adaptors for
Domestic Use) Regulations 1997.
flexible cable or cord and is designed to be
connected to a mains socket conforming to I.S.
411 by means of that flexible cable or cord and
plug, shall be fitted with a 13 A plug in
accordance with Statutory Instrument 525:1997 –
National Standards Authority of Ireland (section
28) (13 A Plugs and Conversion Adaptors for
Domestic Use) Regulations 1997.
N/A
3.2.3 C:
Delete Note 1 and in Table 3A, delete the
conduit sizes in parentheses.
N/A
Page 68 of 99
ST-06153
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
3.2.5.1 C:
Replace
"60245 IEC 53" by "H05 RR-F";
"60227 IEC 52" by "H03 VV-F or H03 VVH2-F";
"60227 IEC 53" by "H05 VV-F or H05 VVH2-F2".
"60227 IEC 52" by "H03 VV-F or H03 VVH2-F";
"60227 IEC 53" by "H05 VV-F or H05 VVH2-F2".
In Table 3B, replace the first four lines by the
following:
following:
Up to and including 6
0,75
1)
Over 6 up to and including 10 (0,75)
2)
1,0
Over 10 up to and including 16 (1,0)
3)
1,5
In the Conditions applicable to Table 3B delete
the words "in some countries" in condition
the words "in some countries" in condition
1)
.
In Note 1, applicable to Table 3B, delete the
second sentence.
second sentence.
Direct plug-in equipment
N/A
S (GB): In the United Kingdom, a power supply
cord with conductor of 1,25 mm
cord with conductor of 1,25 mm
2
is allowed for
equipment with a rated current over 10 A and up
to and including 13 A.
to and including 13 A.
N/A
3.3.4
C: In Table 3D, delete the fourth line: conductor
sizes for 10 to 13A, and replace with the
following:
sizes for 10 to 13A, and replace with the
following:
Over 10 up to and including 16 1,5 to 2,5 1,5 to 4
Delete the fifth line: conductor sizes for 13 to
16 A.
16 A.
No wiring terminal
N/A
S (GB): In the United Kingdom, the range of
conductor sizes of flexible cords to be accepted
by terminals for equipment with a
conductor sizes of flexible cords to be accepted
by terminals for equipment with a
RATED CURRENT
of over 10 A up to and including 13 A is:
- 1,25 mm
- 1,25 mm
2
to 1,5 mm
2
nominal cross-sectional
area.
N/A
4.3.6
S (GB): In the United Kingdom, the torque test
is performed using a socket outlet complying with
BS 1363 and the plug part of DIRECT PLUG-IN
EQUIPMENT shall be assessed to BS 1363: Part
1, 12.1, 12.2, 12.3, 12.9, 12.11, 12.12, 12.16 and
12.17, except that the test of 12.17 is performed
at not less than 125
is performed using a socket outlet complying with
BS 1363 and the plug part of DIRECT PLUG-IN
EQUIPMENT shall be assessed to BS 1363: Part
1, 12.1, 12.2, 12.3, 12.9, 12.11, 12.12, 12.16 and
12.17, except that the test of 12.17 is performed
at not less than 125
°C.
P
S (IE): In Ireland, DIRECT PLUG-IN
EQUIPMENT is known as plug similar devices.
Such devices shall comply with Statutory
Instrument 526:1997 – National Standards
Authority of Ireland (Section 28) (Electrical plugs,
plug similar devices and sockets for domestic
use) Regulations, 1997.
EQUIPMENT is known as plug similar devices.
Such devices shall comply with Statutory
Instrument 526:1997 – National Standards
Authority of Ireland (Section 28) (Electrical plugs,
plug similar devices and sockets for domestic
use) Regulations, 1997.
P