EMC - CB Certificate
Brand
Device
Audio
File
on-call-sm2.pdf
Date

JBL ON CALL (serv.man2) EMC - CB Certificate ▷ View online

 
 
 
 
Page 65 of 99 
ST-06153 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
2.7.1 C: 
Replace the subclause as follows: 
Basic requirements 
To protect against excessive current, short-
circuits and earth faults in PRIMARY CIRCUITS, 
protective devices shall be included either as 
integral parts of the equipment or as parts of the 
building installation, subject to the following, a), 
b) and c): 
a)  except as detailed in b) and c), protective 
devices necessary to comply with the 
requirements of 5.3 shall be included as 
parts of the equipment; 
b)  for components in series with the mains input 
to the equipment such as the supply cord, 
appliance coupler, r.f.i. filter and switch, 
short-circuit and earth fault protection may be 
provided by protective devices in the building 
installation; 
c)  it is permitted for PLUGGABLE EQUIPMENT 
TYPE B or PERMANENTLY CONNECTED 
EQUIPMENT, to rely on dedicated 
overcurrent and short-circuit protection in the 
building installation, provided that the means 
of protection, e.g. fuses or circuit breakers, is 
fully specified in the installation instructions. 
If reliance is placed on protection in the building 
installation, the installation instructions shall so 
state, except that for PLUGGABLE EQUIPMENT 
TYPE A the building installation shall be 
regarded as providing protection in accordance 
with the rating of the wall socket outlet. 
Considered P 
 
S (GB): In the United Kingdom, to protect 
against excessive currents and short-circuits in 
the PRIMARY CIRCUIT OF DIRECT PLUG-IN 
EQUIPMENT, protective device shall be included 
as integral parts of the DIRECT PLUG-IN 
EQUIPMENT. 
 P 
2.7.2 
C: This subclause has been declared 'void'.  
N/A 
2.10.2 C: 
Replace in the first line "(see also 1.4.7)" by 
"(see also 1.4.8)". 
 P 
 
 
 
 
Page 66 of 99 
ST-06153 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
 
TRF No.: IECEN60950_1A 
 
 
2.10.3.1 
S (NO): In Norway, due to the IT power 
distribution system used (see annex V, Fig. V.7), 
the 
A
.
C
.  
MAINS SUPPLY
 voltage is considered to 
be equal to the line-to-line voltage and will 
remain at 230 V in case of a single earth fault. 
 P 
3.2.1.1 
S (CH): In Switzerland, supply cords of 
equipment having a 
RATED CURRENT
 not 
exceeding 10 A shall be provided with a plug 
complying with SEV 1011 or IEC 60884-1 and 
one of the following dimension sheets: 
SEV 6532-2.1991, Plug type 15, 3P+N+PE   250/400 V, 10 A
SEV 6533-2.1991, Plug type 11, L+N 
250 V, 10 A 
SEV 6534-2.1991, Plug type 12, L+N+PE 
250 V, 10 A 
In general, EN 60309 applies for plugs for 
currents exceeding 10A. However, a 16 A plug 
and socket-outlet system is being introduced in 
Switzerland, the plugs of which are according to 
the following dimension sheets, published in 
February 1998: 
SEV 5932-2.1998, Plug type 25, 3L+N+PE   230/400 V, 16 A
SEV 5933-2.1998, Plug type 21, L+N 
250 V, 16 A 
SEV 5934-2.1998, Plug type 23, L+N+PE 
250 V, 16 A
 
Direct plug-in equipment 
N/A 
 S 
(DK): In Denmark, supply cords of single-
phase equipment having a rated current not 
exceeding 13 A shall be provided with a plug 
according to the Heavy Current 
Regulations,Section 107-2-D1. 
CLASS I EQUIPMENT provided with socket-
outlets with earth contacts or which are intended 
to be used in locations where protection against 
indirect contact is required according to the 
wiring rules shall be provided with a plug in 
accordance with standard sheet DK 2-1a or DK 
2-5a. 
If poly-phase equipment and single-phase 
equipment having a RATED CURRENT 
exceeding 13 A is provided with a supply cord 
with a plug, this plug shall be in accordance with 
the Heavy Current Regulations, Section 107-2-
D1 or EN 60309-2. 
 N/A 
 
 
 
 
Page 67 of 99 
ST-06153 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
 
TRF No.: IECEN60950_1A 
 
 
 
S (ES): In Spain, supply cords of single-phase 
equipment having a rated current not exceeding 
10 A shall be provided with a plug according to 
UNE 20315:1994. 
Supply cords of single-phase equipment having a 
rated current not exceeding 2,5 A shall be 
provided with a plug according to 
UNE-EN 50075:1993. 
CLASS I EQUIPMENT provided with socket-
outlets with earth contacts or which are intended 
to be used in locations where protection against 
indirect contact is required according to the 
wiring rules, shall be provided with a plug in 
accordance with standard UNE 20315:1994. 
If poly-phase equipment is provided with a supply 
cord with a plug, this plug shall be in accordance 
with UNE-EN 60309-2. 
 N/A 
 
S (GB): In the United Kingdom, apparatus 
which is fitted with a flexible cable or cord and is 
designed to be connected to a mains socket 
conforming to BS 1363 by means of that flexible 
cable or cord and plug, shall be fitted with a 
'standard plug' in accordance with Statutory 
Instrument 1768:1994 – The Plugs and Socket 
etc. (Safety) Regulations 1994, unless exempted 
by those regulations. 
NOTE – 'Standard plug' is defined in 
SI 1768:1994 and essentially means an 
approved plug conforming to BS 1363 or an 
approved conversion plug.  
 N/A 
 
S (IE): In Ireland, apparatus which is fitted with a 
flexible cable or cord and is designed to be 
connected to a mains socket conforming to I.S. 
411 by means of that flexible cable or cord and 
plug, shall be fitted with a 13 A plug in 
accordance with Statutory Instrument 525:1997 – 
National Standards Authority of Ireland (section 
28) (13 A Plugs and Conversion Adaptors for 
Domestic Use) Regulations 1997. 
 N/A 
3.2.3 C: 
Delete Note 1 and in Table 3A, delete the 
conduit sizes in parentheses. 
 N/A 
 
 
 
 
Page 68 of 99 
ST-06153 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
 
TRF No.: IECEN60950_1A 
 
 
3.2.5.1 C: 
Replace 
"60245 IEC 53"  by "H05 RR-F"; 
"60227 IEC 52"  by "H03 VV-F or H03 VVH2-F";
"60227 IEC 53"  by "H05 VV-F or H05 VVH2-F2".
In Table 3B, replace the first four lines by the 
following: 
Up to and including 6  
 
0,75
1)
 
Over 6 up to and including 10  (0,75)
2) 
1,0 
Over 10 up to and including 16 (1,0)
3)
 1,5 
In the Conditions applicable to Table 3B delete 
the words "in some countries" in condition 
1)
In Note 1, applicable to Table 3B, delete the 
second sentence. 
Direct plug-in equipment 
N/A 
 
S (GB): In the United Kingdom, a power supply 
cord with conductor of 1,25 mm
2
 is allowed for 
equipment with a rated current over 10 A and up 
to and including 13 A. 
 N/A 
3.3.4 
C: In Table 3D, delete the fourth line: conductor 
sizes for 10 to 13A, and replace with the 
following: 
Over 10 up to and including 16   1,5 to 2,5   1,5 to 4 
Delete the fifth line: conductor sizes for 13 to 
16 A. 
No wiring terminal 
N/A 
 
S (GB): In the United Kingdom, the range of 
conductor sizes of flexible cords to be accepted 
by terminals for equipment with a
 RATED CURRENT
 
of over 10 A up to and including 13 A is: 
- 1,25 mm
2
 to 1,5 mm
2
 nominal cross-sectional 
area. 
 N/A 
4.3.6 
S (GB): In the United Kingdom, the torque test 
is performed using a socket outlet complying with 
BS 1363 and the plug part of DIRECT PLUG-IN 
EQUIPMENT shall be assessed to BS 1363: Part 
1, 12.1, 12.2, 12.3, 12.9, 12.11, 12.12, 12.16 and 
12.17, except that the test of 12.17 is performed 
at not less than 125 
°C. 
 P 
 
 
 
 
S (IE): In Ireland, DIRECT PLUG-IN 
EQUIPMENT is known as plug similar devices. 
Such devices shall comply with Statutory 
Instrument 526:1997 – National Standards 
Authority of Ireland (Section 28) (Electrical plugs, 
plug similar devices and sockets for domestic 
use) Regulations, 1997. 