JBL ON CALL (serv.man2) EMC - CB Certificate ▷ View online
Page 69 of 99
ST-06153
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
4.3.13.6 C:
Add the following note:
NOTE Attention is drawn to 1999/519/EC:
Council Recommendation on the limitation of
exposure of the general public to electromagnetic
fields 0 Hz to 300 GHz. Standards taking into
account this recommendation are currently under
development.
Council Recommendation on the limitation of
exposure of the general public to electromagnetic
fields 0 Hz to 300 GHz. Standards taking into
account this recommendation are currently under
development.
N/A
6.1.2.1
S (FI, NO): Add the following text between the
first and second paragraph:
first and second paragraph:
If this insulation is solid, including insulation
forming part of a component, it shall at least
consist of either
forming part of a component, it shall at least
consist of either
- two layers of thin sheet material, each of which
shall pass the electric strength test below, or
shall pass the electric strength test below, or
- one layer having a distance through insulation
of at least 0,4 mm, which shall pass the electric
strength test below.
of at least 0,4 mm, which shall pass the electric
strength test below.
If this insulation forms part of a semiconductor
component (e.g. an optocoupler), there is no
distance through insulation requirement for the
insulation consisting of an insulating compound
completely filling the casing, so that
component (e.g. an optocoupler), there is no
distance through insulation requirement for the
insulation consisting of an insulating compound
completely filling the casing, so that
CLEARANCES
AND CREEPAGE DISTANCES
do not exist, if the
component passes the electric strength test in
accordance with the compliance clause below
and in addition
accordance with the compliance clause below
and in addition
- passes the tests and inspection criteria of
2.10.8 with an electric strength test of 1,5 kV
multiplied by 1,6 (the electric strength test of
2.10.7 shall be performed using 1,5 kV), and
2.10.8 with an electric strength test of 1,5 kV
multiplied by 1,6 (the electric strength test of
2.10.7 shall be performed using 1,5 kV), and
- is subject to
ROUTINGE TESTING
for electric
strength during manufacturing, using a test
voltage of 1,5 kV.
voltage of 1,5 kV.
It is permitted to bridge this insulation with a
capacitor complying with EN 132400:1994,
subclass Y2.
capacitor complying with EN 132400:1994,
subclass Y2.
N/A
Page 70 of 99
ST-06153
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
(cont.)
A capacitor classified Y3 according to
EN 132400:1994, may bridge this insulation
under the following conditions:
EN 132400:1994, may bridge this insulation
under the following conditions:
- the insulation requirements are satisfied by
having a capacitor classified Y3 as defined by
EN 132400, which in addition to the Y3 testing, is
tested with an impulse test of 2,5 kV defined in
EN 60950-1:2001, 6.2.2.1;
having a capacitor classified Y3 as defined by
EN 132400, which in addition to the Y3 testing, is
tested with an impulse test of 2,5 kV defined in
EN 60950-1:2001, 6.2.2.1;
- the additional testing shall be performed on all
the test specimens as described in EN 132400;
the test specimens as described in EN 132400;
- the impulse test of 2,5 kV is to be performed
before the endurance test in EN 132400, in the
sequence of tests as described in EN 132400.
before the endurance test in EN 132400, in the
sequence of tests as described in EN 132400.
N/A
S (SE): the following text is added:
NOTE – In Sweden the following text is added
between the first and second paragraph:
between the first and second paragraph:
In Sweden, If this insulation is solid, including
insulation forming part of a component, it shall at
least consist of either
insulation forming part of a component, it shall at
least consist of either
- two layers of thin sheet material, each of which
shall pass the electric strength test below, or
shall pass the electric strength test below, or
- one layer having a distance through insulation
of at least 0,4 mm, which shall pass the electric
strength test below.
of at least 0,4 mm, which shall pass the electric
strength test below.
If this insulation forms part of a semiconductor
component (e.g. an optocoupler), there is no
distance through insulation requirement for the
insulation consisting of an insulating compound
completely filling the casing, so that
component (e.g. an optocoupler), there is no
distance through insulation requirement for the
insulation consisting of an insulating compound
completely filling the casing, so that
CLEARANCES
AND CREEPAGE DISTANCES
do not exist, if the
component passes the electric strength test in
accordance with the compliance clause below
and in addition
accordance with the compliance clause below
and in addition
- passes the tests and inspection criteria of IEC
60950-1, 2.10.8 with an electric strength test of
1,5 kV multiplied by 1,6 (the electric strength test
of IEC 60950-1, 2.10.7 shall be performed using
1,5 kV), and
60950-1, 2.10.8 with an electric strength test of
1,5 kV multiplied by 1,6 (the electric strength test
of IEC 60950-1, 2.10.7 shall be performed using
1,5 kV), and
- is subject to
ROUTINGE TESTING
for electric
strength during manufacturing, using a test
voltage of 1,5 kV.
voltage of 1,5 kV.
N/A
Page 71 of 99
ST-06153
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
(cont.)
It is permitted to bridge this insulation with a
capacitor complying with IEC 60384-14:1993,
subclass Y2.
capacitor complying with IEC 60384-14:1993,
subclass Y2.
A capacitor classified Y3 according to
IEC 60384-14, may bridge this insulation under
the following conditions:
IEC 60384-14, may bridge this insulation under
the following conditions:
- the insulation requirements are satisfied by
having a capacitor classified Y3 as defined by
IEC 60384-14, which in addition to the Y3 testing,
is tested with an impulse test of 2,5 kV defined in
IEC 60950-1:2001, 6.2.2.1;
having a capacitor classified Y3 as defined by
IEC 60384-14, which in addition to the Y3 testing,
is tested with an impulse test of 2,5 kV defined in
IEC 60950-1:2001, 6.2.2.1;
- the additional testing shall be performed on all
the test specimens as described in IEC 60384-
14;
the test specimens as described in IEC 60384-
14;
- the impulse test of 2,5 kV is to be performed
before the Endurance Test in IEC 60384-14, in
the sequence of tests as described in IEC 60384-
14.
before the Endurance Test in IEC 60384-14, in
the sequence of tests as described in IEC 60384-
14.
N/A
6.1.2.2
S (FI, NO, SE): The exclusions are applicable for
PERMANENTLY CONNECTED EQUIPMENT
and
PERMANENTLY CONNECTED EQUIPMENT
and
PLUGGABLE EQUIPMENT TYPE B and
equipment intended to be used in a
RESTRICTED ACCESS LOCATION where
equipotential bonding has been applied, e.g. in a
telecommunication centre, and which has
provision for a permanently connected
PROTECTIVE EARTHING CONDUCTOR
RESTRICTED ACCESS LOCATION where
equipotential bonding has been applied, e.g. in a
telecommunication centre, and which has
provision for a permanently connected
PROTECTIVE EARTHING CONDUCTOR
and is
provided with instructions for the installation of
that conductor by a service person.
that conductor by a service person.
N/A
7.1
S (FI, NO, SE): Requirements according to this
annex, 6.1.2.1 and 6.1.2.2 apply with the term
TELECOMMUNICATION NETWORK in 6.1.2
being replaced by the term CABLE
DISTRIBUTION SYSTEM.
annex, 6.1.2.1 and 6.1.2.2 apply with the term
TELECOMMUNICATION NETWORK in 6.1.2
being replaced by the term CABLE
DISTRIBUTION SYSTEM.
N/A
G.2.1
S (NO): In Norway, Due to the IT power
distribution system used (see annex V, Fig. V.7),
the A.C. MAINS SUPPLY voltage is considered
to be equal to the line-to-line voltage, and will
remain at 230 V in case of a single earth fault.
distribution system used (see annex V, Fig. V.7),
the A.C. MAINS SUPPLY voltage is considered
to be equal to the line-to-line voltage, and will
remain at 230 V in case of a single earth fault.
N/A
Page 72 of 99
ST-06153
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
Annex H
C: Replace the last paragraph of this annex by:
At any point 10 cm from the surface of the
operator access area, the dose rate shall not
exceed 1
operator access area, the dose rate shall not
exceed 1
µSv/h (0,1 mR/h) (see note). Account is
taken of the background level.
Replace the notes as follows:
NOTE These values appear in Directive
96/29/Euratom.
96/29/Euratom.
Delete Note 2.
The EUT does not produce
ionizing radiation
ionizing radiation
N/A
Annex P
C: Replace the text of this annex by:
See annex ZA.
P
Annex Q
C: Replace the title of IEC 61032 by "Protection of persons and equipment by
enclosures – Probes for verification".
enclosures – Probes for verification".
Add the following notes for the standards indicated:
P