Page 69 of 99 
ST-06153 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
 
TRF No.: IECEN60950_1A 
 
 
4.3.13.6 C: 
Add the following note: 
NOTE Attention is drawn to 1999/519/EC: 
Council Recommendation on the limitation of 
exposure of the general public to electromagnetic 
fields 0 Hz to 300 GHz. Standards taking into 
account this recommendation are currently under 
development. 
 N/A 
6.1.2.1 
S (FI, NO): Add the following text between the 
first and second paragraph: 
If this insulation is solid, including insulation 
forming part of a component, it shall at least 
consist of either 
- two layers of thin sheet material, each of which 
shall pass the electric strength test below, or 
- one layer having a distance through insulation 
of at least 0,4 mm, which shall pass the electric 
strength test below. 
If this insulation forms part of a semiconductor 
component (e.g. an optocoupler), there is no 
distance through insulation requirement for the 
insulation consisting of an insulating compound 
completely filling the casing, so that 
CLEARANCES 
AND CREEPAGE DISTANCES
 do not exist, if the 
component passes the electric strength test in 
accordance with the compliance clause below 
and in addition 
- passes the tests and inspection criteria of 
2.10.8 with an electric strength test of 1,5 kV 
multiplied by 1,6 (the electric strength test of 
2.10.7 shall be performed using 1,5 kV), and 
- is subject to 
ROUTINGE TESTING
 for electric 
strength during manufacturing, using a test 
voltage of 1,5 kV. 
It is permitted to bridge this insulation with a 
capacitor complying with EN 132400:1994, 
subclass Y2. 
 N/A 
 
 
 
 
Page 70 of 99 
ST-06153 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
(cont.) 
A capacitor classified Y3 according to 
EN 132400:1994, may bridge this insulation 
under the following conditions: 
- the insulation requirements are satisfied by 
having a capacitor classified Y3 as defined by 
EN 132400, which in addition to the Y3 testing, is 
tested with an impulse test of 2,5 kV defined in 
EN 60950-1:2001, 6.2.2.1; 
- the additional testing shall be performed on all 
the test specimens as described in EN 132400; 
- the impulse test of 2,5 kV is to be performed 
before the endurance test in EN 132400, in the 
sequence of tests as described in EN 132400. 
 N/A 
 
S (SE): the following text is added: 
NOTE – In Sweden the following text is added 
between the first and second paragraph: 
In Sweden, If this insulation is solid, including 
insulation forming part of a component, it shall at 
least consist of either 
- two layers of thin sheet material, each of which 
shall pass the electric strength test below, or 
- one layer having a distance through insulation 
of at least 0,4 mm, which shall pass the electric 
strength test below. 
If this insulation forms part of a semiconductor 
component (e.g. an optocoupler), there is no 
distance through insulation requirement for the 
insulation consisting of an insulating compound 
completely filling the casing, so that 
CLEARANCES 
AND CREEPAGE DISTANCES
 do not exist, if the 
component passes the electric strength test in 
accordance with the compliance clause below 
and in addition 
- passes the tests and inspection criteria of IEC 
60950-1, 2.10.8 with an electric strength test of 
1,5 kV multiplied by 1,6 (the electric strength test 
of IEC 60950-1, 2.10.7 shall be performed using 
1,5 kV), and 
- is subject to 
ROUTINGE TESTING
 for electric 
strength during manufacturing, using a test 
voltage of 1,5 kV. 
 N/A 
 
 
 
 
Page 71 of 99 
ST-06153 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
(cont.) 
It is permitted to bridge this insulation with a 
capacitor complying with IEC 60384-14:1993, 
subclass Y2. 
A capacitor classified Y3 according to 
IEC 60384-14, may bridge this insulation under 
the following conditions: 
- the insulation requirements are satisfied by 
having a capacitor classified Y3 as defined by 
IEC 60384-14, which in addition to the Y3 testing, 
is tested with an impulse test of 2,5 kV defined in 
IEC 60950-1:2001, 6.2.2.1; 
- the additional testing shall be performed on all 
the test specimens as described in IEC 60384-
14; 
- the impulse test of 2,5 kV is to be performed 
before the Endurance Test in IEC 60384-14, in 
the sequence of tests as described in IEC 60384-
14. 
 N/A 
6.1.2.2 
S (FI, NO, SE): The exclusions are applicable for 
PERMANENTLY CONNECTED EQUIPMENT 
and
 
PLUGGABLE EQUIPMENT TYPE B and 
equipment intended to be used in a 
RESTRICTED ACCESS LOCATION where 
equipotential bonding has been applied, e.g. in a 
telecommunication centre, and which has 
provision for a permanently connected 
PROTECTIVE EARTHING CONDUCTOR
 
and is 
provided with instructions for the installation of 
that conductor by a service person. 
 N/A 
7.1 
S (FI, NO, SE): Requirements according to this 
annex, 6.1.2.1 and 6.1.2.2 apply with the term 
TELECOMMUNICATION NETWORK in 6.1.2 
being replaced by the term CABLE 
DISTRIBUTION SYSTEM. 
 N/A 
G.2.1 
S (NO): In Norway, Due to the IT power 
distribution system used (see annex V, Fig. V.7), 
the A.C. MAINS SUPPLY voltage is considered 
to be equal to the line-to-line voltage, and will 
remain at 230 V in case of a single earth fault. 
 N/A 
 
 
 
 
Page 72 of 99 
ST-06153 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
 
TRF No.: IECEN60950_1A 
 
 
Annex H 
C: Replace the last paragraph of this annex by: 
At any point 10 cm from the surface of the 
operator access area, the dose rate shall not 
exceed 1 
µSv/h (0,1 mR/h) (see note). Account is 
taken of the background level. 
Replace the notes as follows: 
NOTE  These values appear in Directive 
96/29/Euratom.  
Delete Note 2. 
The EUT does not produce 
ionizing radiation 
N/A 
Annex P 
C: Replace the text of this annex by: 
See annex ZA. 
 P 
Annex Q 
C: Replace the title of IEC 61032 by "Protection of persons and equipment by 
enclosures – Probes for verification". 
Add the following notes for the standards indicated: 
 
 
 
Page of 127
Display