Page 9 of 99 
ST-06153 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
 
TRF No.: IECEN60950_1A 
 
 
 
2.2.3.2 
Separation by earthed screen (method 2) 
 
N/A 
2.2.3.3 
Protection by earthing of the SELV circuit 
(method 3) 
 N/A 
2.2.4 
Connection of SELV circuits to other circuits....... : SELV circuits only connected to 
SELV circuits 
Note: 
Model MU15-C240010-C5: 
The voltage measured between T1, pin A-B is 66.8 Vpeak 
The voltage measured between T1 after D7 is 24.1 Vdc 
 
2.3 TNV 
circuits 
 
2.3.1 
Limits 
No TNV circuit within the EUT 
N/A 
 
Type of TNV circuits............................................ :  
 
2.3.2 
Separation from other circuits and from 
accessible parts 
 
N/A 
 Insulation 
employed ............................................ :  
 
2.3.3 Separation 
from hazardous voltages 
 
N/A 
 Insulation 
employed ............................................ :  
 
2.3.4 
Connection of TNV circuits to other circuits 
 
N/A 
 Insulation 
employed ............................................ :  
 
2.3.5 
Test for operating voltages generated externally 
 
N/A 
 
2.4 
Limited current circuits 
 
2.4.1 General 
requirements 
 
2.4.2 Limit 
values 
 
 Frequency 
(Hz) ................................................... : See the Note on next page 
 
 Measured 
current (mA) ....................................... : See the Note on next page 
 
 Measured 
voltage 
(V).......................................... : See the Note on next page 
 
 
Measured capacitance (
µF) ................................: Measured max. 2200 pF 
 
2.4.3 
Connection of limited current circuits to other 
circuits 
 N/A 
 
 
 
 
Page 10 of 99 
ST-06153 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
Note: 
The measurement is conducted between the output connector and earth. 
Model MU15-C033280-C5: 
Voltage = 0.86 Vpeak, Frequency = 60 Hz, Current = 0.43 mA, Limited = 0.7 mA; 
Voltage = 0.98 Vpeak, Frequency = 60 kHz, Current = 0.49 mA, Limited = 42 mA (0.7 x 60). 
The measurement is conducted between CY1 secondary and earth. 
Voltage = 1.02 Vpeak, Frequency = 60 Hz, Current = 0.51 mA, Limit = 0.7 mA; 
Voltage = 1.18 Vpeak, Frequency = 60 kHz, Current = 0.59 mA, Limit = 42 mA (0.7 
× 60). 
Model MU15-C060250-C5: 
Voltage = 1.02 Vpeak, Frequency = 60 Hz, Current = 0.51 mA, Limited = 0.7 mA; 
Voltage = 1.4 Vpeak, Frequency = 60 kHz, Current = 0.70 mA, Limited = 42 mA (0.7 x 60). 
The measurement is conducted between CY1 secondary and earth. 
Voltage = 1.06 Vpeak, Frequency = 60 Hz, Current = 0.53 mA, Limit = 0.7 mA; 
Voltage = 1.86 Vpeak, Frequency = 60 kHz, Current = 0.93 mA, Limit = 42 mA (0.7 
× 60). 
Model MU15-C240010-C5: 
Voltage = 1.08 Vpeak, Frequency = 60 Hz, Current = 0.54 mA, Limited = 0.7 mA; 
Voltage = 1.37 Vpeak, Frequency = 60 kHz, Current = 0.69 mA, Limited = 42 mA (0.7 x 60). 
The measurement is conducted between CY1 secondary and earth. 
Voltage = 1.44 Vpeak, Frequency = 60 Hz, Current = 0.57 mA, Limit = 0.7 mA; 
Voltage = 1.44 Vpeak, Frequency = 60 kHz, Current = 0.72 mA, Limit = 42 mA (0.7 
× 60). 
 
2.5 
Limited power sources 
 
 
Inherently limited output 
 
 
Impedance limited output 
 
N/A 
 
Overcurrent protective device limited output 
 
N/A 
 
Regulating network limited output under normal 
operating and single fault condition 
 P 
 
Regulating network limited output under normal 
operating conditions and overcurrent protective 
device limited output under single fault condition 
 N/A 
 
Output voltage (V), output current (A), apparent 
power (VA) .........................................................: 
See the Note on next page 
 
 
Current rating of overcurrent protective device (A)  
 
 
 
 
 
Page 11 of 99 
ST-06153 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
Note: 
The output of the power supply complies with the requirement of inherently Limited Power Source. 
Model MU15-C033280-C5: 
Limits: Isc 
≤ 8.0 A, S ≤ 17.40 VA (5 x Uoc).  
Measured Uoc = 3.48 Vdc, Isc = 4.15 A, S = 11.5 VA (2.77 Vdc 
× 4.15 A), under the maximum normal 
operation (the worst case include single faults). 
Model MU15-C060250-C5: 
Limits: Isc 
≤ 8.0 A, S ≤ 30.25 VA (5 x Uoc).  
Measured Uoc = 6.05 Vdc, Isc = 4.17 A, S = 22.6 VA (5.42 Vdc 
× 4.17 A), under the maximum normal 
operation (the worst case include single faults). 
Model MU15-C240010-C5: 
Limits: Isc 
≤ 8.0 A, S ≤ 100 VA. (5 x Uoc). 
Measured Uoc = 24.04 Vdc, Isc = 1.83 A, S = 43.4 VA (23.71 Vdc 
× 1.83 A), under the maximum normal 
operation (the worst case include single faults). 
 
 
 
 
 
Page 12 of 99 
ST-06153 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
2.6 
Provisions for earthing and bonding 
 
2.6.1 
Protective earthing 
Class II equipment 
N/A 
2.6.2 Functional 
earthing 
 
N/A 
2.6.3 
Protective earthing and protective bonding 
conductors 
 N/A 
2.6.3.1 General 
 
N/A 
2.6.3.2 
Size of protective earthing conductors 
 
N/A 
 
Rated current (A), cross-sectional area (mm
2
), 
AWG.................................................................... :
 
 
2.6.3.3 
Size of protective bonding conductors 
 
N/A 
 
Rated current (A), cross-sectional area (mm
2
), 
AWG.................................................................... :
 
 
2.6.3.4 
Resistance (
Ω) of earthing conductors and their 
terminations, test current (A)............................... :
 N/A 
2.6.3.5 Colour 
of 
insulation ............................................. :  N/A 
2.6.4 Terminals 
 
N/A 
2.6.4.1 General 
 
N/A 
2.6.4.2 
Protective earthing and bonding terminals 
 
N/A 
 
Rated current (A), type and nominal thread 
diameter (mm)..................................................... :
 
 
2.6.4.3 
Separation of the protective earthing conductor 
from protective bonding conductors 
 N/A 
2.6.5 
Integrity of protective earthing 
 
N/A 
2.6.5.1 
Interconnection of equipment 
 
N/A 
2.6.5.2 
Components in protective earthing conductors 
and protective bonding conductors 
 N/A 
2.6.5.3 
Disconnection of protective earth 
 
N/A 
2.6.5.4 
Parts that can be removed by an operator 
 
N/A 