DOWNLOAD JBL ON BEAT RUMBLE Service Manual ↓ Size: 1.85 MB | Pages: 116 in PDF or view online for FREE

Model
ON BEAT RUMBLE
Pages
116
Size
1.85 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
on-beat-rumble.pdf
Date

JBL ON BEAT RUMBLE EMC - CB Certificate ▷ View online

Issue Date: 
2013-01-09 
Page 9 of 54 
Report Reference # 
E204594-A39-CB-1 
 
 
 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. : IEC60950_1B 
This report issued under the responsibility of UL 
  
GENERAL 
Pass 
1.5 
Components 
Pass 
1.5.1 
General 
 
Pass 
 
Comply with IEC 60950-1 or relevant component 
standard 
(See appended table 1.5.1) 
Pass 
1.5.2 
Evaluation and testing of components 
Components certified to IEC 
harmonized standard and 
checked for correct 
application. 
 
Components not certified are 
used in accordance with their 
ratings and they comply with 
applicable parts of IEC 60950-
1 and the relevant component 
Standard. 
 
Components, for which no 
relevant IEC-Standard exist, 
have been tested under the 
conditions occurring in the 
equipment, using applicable 
parts of IEC 60950-1. 
Pass 
1.5.3 
Thermal controls 
 
N/A 
1.5.4 
Transformers 
 
N/A 
1.5.5 
Interconnecting cables 
Not provided. 
N/A 
1.5.6 
Capacitors bridging insulation 
 
N/A 
1.5.7 
Resistors bridging insulation 
 
N/A 
1.5.7.1 
Resistors bridging functional, basic or 
supplementary insulation 
 
N/A 
1.5.7.2 
Resistors bridging double or reinforced insulation 
between a.c. mains and other circuits 
 
N/A 
1.5.7.3 
Resistors bridging double or reinforced insulation 
between a.c. mains and antenna or coaxial cable 
 
N/A 
1.5.8 
Components in equipment for IT power systems 
 
N/A 
1.5.9 
Surge suppressors 
No surge suppressor used. 
N/A 
1.5.9.1 
General 
 
N/A 
1.5.9.2 
Protection of VDRs 
 
N/A 
Issue Date: 
2013-01-09 
Page 10 of 54 
Report Reference # 
E204594-A39-CB-1 
 
 
 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. : IEC60950_1B 
This report issued under the responsibility of UL 
  
1.5.9.3 
Bridging of functional insulation by a VDR 
 
N/A 
1.5.9.4 
Bridging of basic insulation by a VDR 
 
N/A 
1.5.9.5 
Bridging of supplementary, double or reinforced 
insulation by a VDR 
 
N/A 
 
1.6 
Power interface 
Pass 
1.6.1 
AC power distribution systems 
Class III equipment intended to 
be supplied by an external 
SELV power supply marked 
LPS. 
Pass 
1.6.2 
Input current 
For reference only. The steady 
state input current of the 
equipment did not exceed the 
RATED CURRENT by more 
than 10% under NORMAL 
LOAD. 
See appended Table 1.6.2. 
Pass 
1.6.3 
Voltage limit of hand-held equipment 
 
N/A 
1.6.4 
Neutral conductor 
 
N/A 
 
Issue Date: 
2013-01-09 
Page 11 of 54 
Report Reference # 
E204594-A39-CB-1 
 
 
 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. : IEC60950_1B 
This report issued under the responsibility of UL 
  
1.7 
Marking and instructions 
Pass 
1.7.1 
Power rating and identification markings 
 
Pass 
1.7.1.1 
Power rating mark 
 
Pass 
 
Multiple mains supply connections ........... :  
 
N/A 
 
Rated voltage(s) or voltage range(s) (V) .. :  
18Vdc (optional) 
Pass 
 
Symbol for nature of supply, for d.c. only . :  
DC symbol provided (optional) 
Pass 
 
Rated frequency or rated frequency range 
(Hz) .......................................................... :  
DC only 
N/A 
 
Rated current (mA or A) ........................... :  
3.3A (optional) 
Pass 
1.7.1.2 
Identification markings 
 
Pass 
 
Manufacturer's name or trademark or 
identification mark .................................... :  
HARMAN INTERNATIONAL 
INDUSTRIES, INC or 
trademark JBL 
Pass 
 
Model identification or type reference ...... :  
Refer to the Model information 
at the beginning of this Test 
Report. 
Pass 
 
Symbol for Class II equipment only .......... :  
Class III equipment 
N/A 
 
Other markings and symbols .................... :  
 
N/A 
1.7.2 
Safety instructions and marking 
Operating/safety instructions 
made available to the user. 
Pass 
1.7.2.1 
General 
 
Pass 
1.7.2.2 
Disconnect devices 
 
N/A 
1.7.2.3 
Overcurrent protective device 
 
N/A 
1.7.2.4 
IT Power distribution systems 
 
N/A 
1.7.2.5 
Operator access with a tool 
 
N/A 
1.7.2.6 
Ozone 
 
N/A 
1.7.3 
Short duty cycles 
 
N/A 
1.7.4 
Supply voltage adjustment ....................... :  
 
N/A 
 
Method and means of adjustment; 
reference to installation instructions ......... :  
 
N/A 
1.7.5 
Power outlets on the equipment ............... :  
 
N/A 
1.7.6 
Fuse identification (marking, special fusing 
characteristics, cross-reference) .............. :  
 
N/A 
Issue Date: 
2013-01-09 
Page 12 of 54 
Report Reference # 
E204594-A39-CB-1 
 
 
 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. : IEC60950_1B 
This report issued under the responsibility of UL 
  
1.7.7 
Wiring terminals 
Class III equipment 
N/A 
1.7.7.1 
Protective earthing and bonding terminals:  
 
N/A 
1.7.7.2 
Terminals for a.c. mains supply conductors 
 
N/A 
1.7.7.3 
Terminals for d.c. mains supply conductors 
 
N/A 
1.7.8 
Controls and indicators 
 
Pass 
1.7.8.1 
Identification, location and marking .......... :  
The function of controls is 
obvious regardless of 
language. 
Pass 
1.7.8.2 
Colours ..................................................... :  
Only functional indicators use 
color. 
N/A 
1.7.8.3 
Symbols according to IEC 60417 ............. :  
The stand-by switch is marked 
with the correct symbol 
(60417-1-IEC-5009). 
Pass 
1.7.8.4 
Markings using figures ............................. :  
 
N/A 
1.7.9 
Isolation of multiple power sources .......... :  
 
N/A 
1.7.10 
Thermostats and other regulating devices:  
 
N/A 
1.7.11 
Durability 
The marking(s) withstood the 
required test. 
Pass 
1.7.12 
Removable parts 
No removable parts. 
N/A 
1.7.13 
Replaceable batteries............................... :  
No replaceable batteries 
provided in the product 
N/A 
 
Language(s) ............................................. :  
 
1.7.14 
Equipment for restricted access locations :  
 
N/A 
 
Page of 116
Display

Click on the first or last page to see other ON BEAT RUMBLE service manuals if exist.