DOWNLOAD JBL ON BEAT RUMBLE Service Manual ↓ Size: 1.85 MB | Pages: 116 in PDF or view online for FREE

Model
ON BEAT RUMBLE
Pages
116
Size
1.85 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
on-beat-rumble.pdf
Date

JBL ON BEAT RUMBLE EMC - CB Certificate ▷ View online

Issue Date: 
2013-01-09 
Page 33 of 54 
Report Reference # 
E204594-A39-CB-1 
 
 
 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. : IEC60950_1B 
This report issued under the responsibility of UL 
  
telecommunication networks 
 
a) EUT with earthed telecommunication 
ports ......................................................... :  
 
N/A 
 
b) EUT whose telecommunication ports have no 
reference to protective earth 
 
N/A 
 
5.2 
Electric strength 
N/A 
5.2.1 
General 
 
N/A 
5.2.2 
Test procedure 
 
N/A 
 
5.3 
Abnormal operating and fault conditions 
Pass 
5.3.1 
Protection against overload and abnormal 
operation 
 
N/A 
5.3.2 
Motors 
 
N/A 
5.3.3 
Transformers 
 
N/A 
5.3.4 
Functional insulation ................................ :  
Method c 
Pass 
5.3.5 
Electromechanical components 
 
N/A 
5.3.6 
Audio amplifiers in ITE ............................. :  
See table 5.3 
Pass 
5.3.7 
Simulation of faults 
 
N/A 
5.3.8 
Unattended equipment 
 
N/A 
5.3.9 
Compliance criteria for abnormal operating and 
fault conditions 
 
Pass 
5.3.9.1 
During the tests 
No fire, emission of molten 
metal or deformation was 
noted during the tests. 
Pass 
5.3.9.2 
After the tests 
 
N/A 
 
Issue Date: 
2013-01-09 
Page 34 of 54 
Report Reference # 
E204594-A39-CB-1 
 
 
 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. : IEC60950_1B 
This report issued under the responsibility of UL 
  
CONNECTION TO TELECOMMUNICATION NETWORKS 
N/A 
6.1 
Protection of telecommunication network service persons, and users of other 
equipment connected to the network, from hazards in the equipment 
N/A 
6.1.1 
Protection from hazardous voltages 
N/A 
6.1.2 
Separation of the telecommunication network from earth 
N/A 
6.1.2.1 
Requirements 
 
N/A 
 
Supply voltage (V) .................................... :  
 
 
Current in the test circuit (mA) .................. :  
 
6.1.2.2 
Exclusions ................................................ :  
 
N/A 
 
6.2 
Protection of equipment users from overvoltages on telecommunication 
networks 
N/A 
6.2.1 
Separation requirements 
 
N/A 
6.2.2 
Electric strength test procedure 
 
N/A 
6.2.2.1 
Impulse test 
 
N/A 
6.2.2.2 
Steady-state test 
 
N/A 
6.2.2.3 
Compliance criteria 
 
N/A 
 
6.3 
Protection of the telecommunication wiring system from overheating 
N/A 
 
Max. output current (A)............................. :  
 
 
Current limiting method ............................ :  
 
 
Issue Date: 
2013-01-09 
Page 35 of 54 
Report Reference # 
E204594-A39-CB-1 
 
 
 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. : IEC60950_1B 
This report issued under the responsibility of UL 
  
CONNECTION TO CABLE DISTRIBUTION SYSTEMS 
N/A 
7.1 
General 
 
N/A 
7.2 
Protection of cable distribution system service 
persons, and users of other equipment connected 
to the system, from hazardous voltages in the 
equipment 
 
N/A 
7.3 
Protection of equipment users from overvoltages 
on the cable distribution system 
 
N/A 
7.4 
Insulation between primary circuits and cable 
distribution systems 
 
N/A 
7.4.1 
General 
 
N/A 
7.4.2 
Voltage surge test 
 
N/A 
7.4.3 
Impulse test 
 
N/A 
 
Issue Date: 
2013-01-09 
Page 36 of 54 
Report Reference # 
E204594-A39-CB-1 
 
 
 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. : IEC60950_1B 
This report issued under the responsibility of UL 
  
ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE 
N/A 
A.1 
Flammability test for fire enclosures of movable equipment having a total mass 
exceeding 18 kg, and of stationary equipment (see 4.7.3.2) 
N/A 
A.1.1 
Samples ................................................... :  
 
 
Wall thickness (mm) ................................. :  
 
A.1.2 
Conditioning of samples; temperature (°C)
 ................................................................. :  
 
N/A 
A.1.3 
Mounting of samples ................................ :  
 
N/A 
A.1.4 
Test flame (see IEC 60695-11-3) 
 
N/A 
 
Flame A, B, C or D ................................... :  
 
N/A 
A.1.5 
Test procedure 
 
N/A 
A.1.6 
Compliance criteria 
 
N/A 
 
Sample 1 burning time (s) ........................ :  
 
 
Sample 2 burning time (s) ........................ :  
 
 
Sample 3 burning time (s) ........................ :  
 
A.2 
Flammability test for fire enclosures of movable equipment having a total mass not 
exceeding 18 kg, and for material and components located inside fire enclosures 
(see 4.7.3.2 and 4.7.3.4) 
N/A 
A.2.1 
Samples, material .................................... :  
 
 
Wall thickness (mm) ................................. :  
 
A.2.2 
Conditioning of samples; temperature (°C)
 ................................................................. :  
 
N/A 
A.2.3 
Mounting of samples ................................ :  
 
N/A 
A.2.4 
Test flame (see IEC 60695-11-4) 
 
N/A 
 
Flame A, B or C ........................................ :  
 
A.2.5 
Test procedure 
 
N/A 
A.2.6 
Compliance criteria 
 
N/A 
 
Sample 1 burning time (s) ........................ :  
 
 
Sample 2 burning time (s) ........................ :  
 
 
Sample 3 burning time (s) ........................ :  
 
A.2.7 
Alternative test acc. to IEC 60695-11-5, cl. 5 and 9   
N/A 
Page of 116