JBL ON BEAT RUMBLE EMC - CB Certificate ▷ View online
Issue Date:
2013-01-09
Page 13 of 54
Report Reference #
E204594-A39-CB-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. : IEC60950_1B
This report issued under the responsibility of UL
2
PROTECTION FROM HAZARDS
Pass
2.1
Protection from electric shock and energy hazards
N/A
2.1.1
Protection in operator access areas
Unit supplied by SELV, and no
hazardous voltage generated
within unit.
hazardous voltage generated
within unit.
N/A
2.1.1.1
Access to energized parts
Unit supplied by SELV, and no
hazardous voltage generated
within unit.
hazardous voltage generated
within unit.
N/A
Test by inspection .................................... :
N/A
Test with test finger (Figure 2A) ............... :
N/A
Test with test pin (Figure 2B) ................... :
N/A
Test with test probe (Figure 2C) ............... :
No TNV present.
N/A
2.1.1.2
Battery compartments
N/A
2.1.1.3
Access to ELV wiring
N/A
Working voltage (Vpeak or Vrms);
minimum distance through insulation (mm)
................................................................. :
minimum distance through insulation (mm)
................................................................. :
-
2.1.1.4
Access to hazardous voltage circuit wiring
N/A
2.1.1.5
Energy hazards ........................................ :
No operator access to
hazardous energy.
hazardous energy.
N/A
2.1.1.6
Manual controls
N/A
2.1.1.7
Discharge of capacitors in equipment
N/A
Measured voltage (V); time-constant (s) .. :
-
2.1.1.8
Energy hazards - d.c. mains supply
N/A
a) Capacitor connected to the d.c. mains
supply ....................................................... :
supply ....................................................... :
N/A
N/A
2.1.1.9
Audio amplifiers ........................................ :
N/A
2.1.2
Protection in service access areas
N/A
2.1.3
Protection in restricted access locations
N/A
Issue Date:
2013-01-09
Page 14 of 54
Report Reference #
E204594-A39-CB-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. : IEC60950_1B
This report issued under the responsibility of UL
2.2
SELV circuits
Pass
2.2.1
General requirements
Equipment is supplied by an
external SELV power supply
marked LPS.
external SELV power supply
marked LPS.
Pass
2.2.2
Voltages under normal conditions (V) ...... :
N/A
2.2.3
Voltages under fault conditions (V) .......... :
N/A
2.2.4
Connection of SELV circuits to other
circuits ...................................................... :
circuits ...................................................... :
SELV connected to other
SELV circuits.
SELV circuits.
Pass
2.3
TNV circuits
N/A
2.3.1
Limits
No TNV present.
N/A
Type of TNV circuits ................................. :
-
2.3.2
Separation from other circuits and from accessible
parts
parts
N/A
2.3.2.1
General requirements
N/A
2.3.2.2
Protection by basic insulation
N/A
2.3.2.3
Protection by earthing
N/A
2.3.2.4
Protection by other constructions ............. :
N/A
2.3.3
Separation from hazardous voltages
N/A
Insulation employed ................................. :
-
2.3.4
Connection of TNV circuits to other circuits
N/A
Insulation employed ................................. :
-
2.3.5
Test for operating voltages generated externally
N/A
Issue Date:
2013-01-09
Page 15 of 54
Report Reference #
E204594-A39-CB-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. : IEC60950_1B
This report issued under the responsibility of UL
2.4
Limited current circuits
N/A
2.4.1
General requirements
N/A
2.4.2
Limit values
N/A
Frequency (Hz) ........................................ :
-
Measured current (mA) ............................ :
-
Measured voltage (V) ............................... :
-
Measured circuit capacitance (nF or uF) .. :
-
2.4.3
Connection of limited current circuits to other
circuits
circuits
N/A
2.5
Limited power sources
Pass
a) Inherently limited output
N/A
b) Impedance limited output
N/A
c) Regulating network limited output under normal
operating and single fault condition
operating and single fault condition
Pass
d) Overcurrent protective device limited output
N/A
Max. output voltage (V), max. output
current (A), max. apparent power (VA)..... :
current (A), max. apparent power (VA)..... :
See appended Table 2.5.
-
Current rating of overcurrent protective
device (A) ................................................. :
device (A) ................................................. :
-
Use of integrated circuit (IC) current
limiters ...................................................... :
limiters ...................................................... :
-
Issue Date:
2013-01-09
Page 16 of 54
Report Reference #
E204594-A39-CB-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. : IEC60950_1B
This report issued under the responsibility of UL
2.6
Provisions for earthing and bonding
N/A
2.6.1
Protective earthing
Class III equipment.
N/A
2.6.2
Functional earthing
N/A
2.6.3
Protective earthing and protective bonding
conductors
conductors
N/A
2.6.3.1
General
N/A
2.6.3.2
Size of protective earthing conductors
N/A
Rated current (A), cross-sectional area
(mm²), AWG ............................................. :
(mm²), AWG ............................................. :
-
2.6.3.3
Size of protective bonding conductors
N/A
Rated current (A), cross-sectional area
(mm²), AWG ............................................. :
(mm²), AWG ............................................. :
-
Protective current rating (A), cross-
sectional area (mm²), AWG ...................... :
sectional area (mm²), AWG ...................... :
-
2.6.3.4
Resistance of earthing conductors and
their terminations; resistance (ohm),
voltage drop (V), test current (A), duration
(min) ......................................................... :
their terminations; resistance (ohm),
voltage drop (V), test current (A), duration
(min) ......................................................... :
N/A
2.6.3.5
Colour of insulation .................................. :
N/A
2.6.4
Terminals
N/A
2.6.4.1
General
N/A
2.6.4.2
Protective earthing and bonding terminals
N/A
Rated current (A), type, nominal thread
diameter (mm) .......................................... :
diameter (mm) .......................................... :
-
2.6.4.3
Separation of the protective earthing conductor
from protective bonding conductors
from protective bonding conductors
N/A
2.6.5
Integrity of protective earthing
N/A
2.6.5.1
Interconnection of equipment
N/A
2.6.5.2
Components in protective earthing conductors and
protective bonding conductors
protective bonding conductors
N/A
2.6.5.3
Disconnection of protective earth
N/A
2.6.5.4
Parts that can be removed by an operator
N/A
2.6.5.5
Parts removed during servicing
N/A
Click on the first or last page to see other ON BEAT RUMBLE service manuals if exist.