JBL ON BEAT MICRO (serv.man3) EMC - CB Certificate ▷ View online
Issue Date:
2012-10-23
Page 23 of 41
Report Reference #
E204594-A37-CB-1
IEC 60950-1:2005
SubClause Difference + Test
Result - Remark
Verdict
This report issued under the responsibility of UL
6.1.2.1
Add the following text between the first and
second paragraph of the compliance clause:
If this insulation is solid, including insulation
forming part of a component, it shall at least consist
of either
- two layers of thin sheet material, each of which
shall pass the electric strength test below, or
- one layer having a distance through insulation of
at least 0,4 mm, which shall pass the electric
strength test below.
Alternatively for components, there is no distance
through insulation requirement for the insulation
consisting of an insulating compound completely
filling the casing, so that CLEARANCES and
CREEPAGE DISTANCES do not exist, if the
component passes the electric strength test in
accordance with the compliance clause below and
in addition
- passes the tests and inspection criteria of 2.10.11
with an electric strength test of 1,5 kV multiplied by
1,6 (the electric strength test of 2.10.10 shall be
performed using 1,5 kV), and
- is subject to ROUTINE TESTING for electric
strength during manufacturing, using a test voltage
of 1,5 kV.
It is permitted to bridge this insulation with an
optocoupler complying with 2.10.5.4 b).
It is permitted to bridge this insulation with a
capacitor complying with EN 132400:1994,
subclass Y2.
A capacitor classified Y3 according to EN 132400
[EN 60384-14:2005], may bridge this insulation
under the following conditions:
- the insulation requirements are satisfied by
having a capacitor classified Y3 as defined by EN
132400 [EN 60384-14], which in addition to the Y3
testing, is tested with an impulse test of 2,5 kV
defined in EN 60950-1:2006, 6.2.2.1;
- the additional testing shall be performed on all the
test specimens as described in EN 132400 [EN
60384-14];
- the impulse test of 2,5 kV is to be performed
before the endurance test in EN 132400 [EN
60384-14], in the sequence of tests as described in
N/A
Issue Date:
2012-10-23
Page 24 of 41
Report Reference #
E204594-A37-CB-1
IEC 60950-1:2005
SubClause Difference + Test
Result - Remark
Verdict
This report issued under the responsibility of UL
EN 132400 [EN 60384-14.]
6.1.2.2
The exclusions are applicable for
PERMANENTLY CONNECTED EQUIPMENT and
PLUGGABLE EQUIPMENT TYPE B and
equipment intended to be used in a RESTRICTED
ACCESS LOCATION where equipotential bonding
has been applied, e.g. in a telecommunication
centre, and which has provision for a permanently
connected PROTECTIVE EARTHING
CONDUCTOR and is provided with instructions for
the installation of that conductor by a SERVICE
PERSON.
N/A
7.2
Requirements according to this annex,
6.1.2.1 and 6.1.2.2 apply with the term
TELECOMMUNICATION NETWORK in 6.1.2
being replaced by the term CABLE DISTRIBUTION
SYSTEM.
N/A
7.3
Requirements according to this annex
1.2.13.14 and 1.7.2.1 apply.
N/A
Issue Date:
2012-10-23
Page 25 of 41
Report Reference #
E204594-A37-CB-1
IEC 60950-1:2005
SubClause Difference + Test
Result - Remark
Verdict
This report issued under the responsibility of UL
Switzerland - Differences to IEC 60950-1:2005 (2nd Edition); Am 1:2009
3.2.1.1
Supply cords of equipment having a
RATED CURRENT not exceeding 10A shall be
provided with a plug complying with SEV 1011 or
IEC 60884-1 and one of the following dimension
sheets:
SEV 6532-2 1991
Plug Type 15
3P+N+PE 250/400 V, 10A
SEV 6533-2 1991
Plug Type 11
L+N
250 V, 10A
SEV 6534-2 1991
Plug Type 12
L+N+PE 250V, 10A
In general, EN 60309 applies for plugs for currents
exceeding 10A. However, a 16A plug and socket-
outlet system is being introduced in Switzerland,
the plugs of which are according to the following
dimension sheets, published in February, 1998.
SEV 5932-2 1998:Plug Type 25
exceeding 10A. However, a 16A plug and socket-
outlet system is being introduced in Switzerland,
the plugs of which are according to the following
dimension sheets, published in February, 1998.
SEV 5932-2 1998:Plug Type 25
3L+N+PE 230/400V, 16A
SEV 5933-2 1998:Plug Type 21
L+N
250 V, 16A
SEV 5934-2 1998:Plug Type 23 L+N+PE
250 V, 16A
N/A
3.2.4
Requirements according to this annex
3.2.1.1 apply.
N/A
Issue Date:
2012-10-23
Page 26 of 41
Report Reference #
E204594-A37-CB-1
IEC 60950-1:2005
SubClause Difference + Test
Result - Remark
Verdict
This report issued under the responsibility of UL
USA / Canada - Differences to IEC 60950-1:2005 (2nd Edition); Am 1:2009
1.1
Equipment able to be installed in
accordance with the National Electrical Code
ANSI/NFPA 70 and the Canadian Electrical Code,
Part1, and when applicable, the National Electrical
Safety Code, IEEE C2.
Pass
1.1.1
Equipment able to be installed in
accordance with ANSI/NFPA 75 and NEC Art. 645
unless intended for use outside of computer room
and provided with such instructions.
N/A
1.1.2
Equipment in wire-line communication
facilities serving high-voltage electric power
stations operating at greater than 1kV are
excluded.
N/A
1.1.2
Special requirements apply to equipment
intended for use outdoors.
N/A
1.4.14
For PLUGGABLE EQUIPMENT TYPE A,
the protection in the installation is assumed to be
20 A.
N/A
1.5.1
All IEC standards for components identified
in Annex P.1 replaced by the relevant requirements
of CSA and UL component standards in Annex P.1.
Pass
1.5.1
All IEC standards for components identified
in Annex P.2 alternatively satisfied by the relevant
requirements of CSA and UL component standards
in Annex P.2.
Pass
1.5.5
Interconnecting cables acceptable for the
application regarding voltage, current, temperature,
flammability, mechanical serviceability and the like.
N/A
Click on the first or last page to see other ON BEAT MICRO (serv.man3) service manuals if exist.