JBL ON BEAT MICRO (serv.man3) EMC - CB Certificate ▷ View online

Issue Date: 
2012-10-23 
Page 19 of 41 
Report Reference # 
E204594-A37-CB-1 
 
 
 
 
 
IEC 60950-1:2005 
SubClause  Difference + Test 
Result - Remark 
Verdict 
 
 
This report issued under the responsibility of UL 
  
It is permitted to bridge this insulation with an 
optocoupler complying with 2.10.5.4 b). 
 
It is permitted to bridge this insulation with a 
capacitor complying with EN 132400:1994, 
subclass Y2. 
A capacitor classified Y3 according to EN 123400 
[EN 60384-14:2005], may bridge this insulation 
under the following conditions: 
- the insulation requirements are satisfied by 
having a capacitor classified Y3 as defined by EN 
132400 [EN 60384-14], which in addition to the Y3 
testing, is tested with an impulse test of 2,5 kV 
defined in EN 60950-1:2006, 6.2.2.1; 
- the additional testing shall be performed on all the 
test specimens as described in EN 132400 [EN 
60384-14]; 
- the impulse test of 2,5 kV is to be performed 
before the endurance test in EN 132400 [EN 
60384-14], in the sequence of tests as described in 
EN 132400 [EN 60384-14.] 
           
6.1.2.2
 
 
            The exclusions are applicable for 
PERMANENTLY CONNECTED EQUIPMENT and 
PLUGGABLE EQUIPMENT TYPE B and 
equipment intended to be used in a RESTRICTED 
ACCESS LOCATION where equipotential bonding 
has been applied, e.g. in a telecommunication 
centre, and which has provision for a permanently 
connected PROTECTIVE EARTHING 
CONDUCTOR and is provided with instructions for 
the installation of that conductor by a SERVICE 
PERSON. 
           
 
             
           
N/A
 
7.2
 
 
            Requirements according to this annex, 
6.1.2.1 and 6.1.2.2 apply with the term 
TELECOMMUNICATION NETWORK in 6.1.2 
being replaced by the term CABLE DISTRIBUTION 
SYSTEM. 
           
 
             
           
N/A
 
7.3
 
 
            Refer to EN 60728-11:2005 for installation 
conditions 
           
 
             
           
N/A
 
Issue Date: 
2012-10-23 
Page 20 of 41 
Report Reference # 
E204594-A37-CB-1 
 
 
 
 
 
IEC 60950-1:2005 
SubClause  Difference + Test 
Result - Remark 
Verdict 
 
 
This report issued under the responsibility of UL 
  
7.3
 
 
            Requirements according to this annex 
1.2.13.14 and 1.7.2.1 apply. 
           
 
             
           
N/A
 
 
Spain - Differences to IEC 60950-1:2005 (2nd Edition); Am 1:2009 
 
 
3.2.1.1
 
 
            Supply cords of single-phase equipment 
having a rated current not exceeding 10A shall be 
provided with a plug according to UNE 
20315:1994.  Supply cords of single-phase 
equipment having a rated current not exceeding 
2.5A shall be provided with a plug according to 
UNE-EN 50075:1993.  CLASS 1 EQUIPMENT 
provided with socket-outlets with earth contacts or 
which are intended to be used in locations where 
protection against indirect contact is required 
according to the wiring rules, shall be provided with 
a plug in accordance with standard UNE 
20315:1994.  If poly-phase equipment is provided 
with a supply cord with a plug, this plug shall be in 
accordance with UNE-EN 60309-2. 
           
 
             
           
N/A
 
 
Issue Date: 
2012-10-23 
Page 21 of 41 
Report Reference # 
E204594-A37-CB-1 
 
 
 
 
 
IEC 60950-1:2005 
SubClause  Difference + Test 
Result - Remark 
Verdict 
 
 
This report issued under the responsibility of UL 
  
Sweden - Differences to IEC 60950-1:2005 (2nd Edition); Am 1:2009 
 
 
1.2.13.14
 
 
            Requirements according to this annex 
1.7.2.1 and 7.3 apply. 
           
 
             
           
N/A
 
1.5.7.1
 
 
            Resistors bridging BASIC INSULATION in 
CLASS I PLUGGABLE EQUIPMENT TYPE A must 
comply with the requirements in 1.5.7.2.  In 
addition when a single resistor is used, the resistor 
must withstand the resistor test in 1.5.7.2. 
           
 
             
           
N/A
 
1.5.9.4
 
 
            The third dashed sentence is applicable 
only to equipment as defined by this annex, 6.1.2.2 
           
 
             
           
N/A
 
1.7.2.1
 
 
            CLASS I PLUGGABLE EQUIPMENT TYPE 
A intended for connection to other equipment or a 
network shall, if safety relies on connection to 
protective earth or if surge suppressors are 
connected between the network terminals and 
accessible parts, have a marking stating that the 
equipment must be connected to an earthed mains 
socket-outlet.  The marking text shall 
be:"Apparaten skall anslutas till jordat uttag" 
           
 
             
           
N/A
 
1.7.2.1
 
 
            In Sweden, the screen of the cable 
distribution system is normally not earthed at the 
entrance of the building and there is normally no 
equipotential bonding system within the building. 
Therefore the protective earthing of the building 
installation need to be isolated from the screen of a 
cable distribution system.  It is however accepted 
to provide the insulation external to the equipment 
by an adapter or an interconnection cable with 
galvanic isolator, which may be provided by e.g. a 
retailer. 
The user manual shall then have the following or 
similar information in Norwegian and Swedish 
language respectively, depending on in what 
country the equipment is intended to be used in: 
"Equipment connected to the protective earthing of 
the building installation through the mains 
connection or through other equipment with a 
 
             
           
N/A
 
Issue Date: 
2012-10-23 
Page 22 of 41 
Report Reference # 
E204594-A37-CB-1 
 
 
 
 
 
IEC 60950-1:2005 
SubClause  Difference + Test 
Result - Remark 
Verdict 
 
 
This report issued under the responsibility of UL 
  
connection to protective earthing - and to a cable 
distribution system using coaxial cable, may in 
some circumstances create a fire hazard.  
Connection to a cable distribution system has 
therefore to be provided through a device providing 
electrical isolation below a certain frequency range 
(galvanic isolator, see EN 60728-11)." 
NOTE: In Norway, due to regulation for installations 
of cable distribution systems, and in Sweden, a 
galvanic isolator shall provide electrical insulation 
below 5 MHz. The insulation shall withstand a 
dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 Hz, 
for 1 min. 
Translation to Swedish: "Utrustning som är kopplad 
till skyddsjord via jordat vägguttag och/eller via 
annan utrustning och samtidigt är kopplad till kabel-
TV nät kan i vissa fall medfõra risk fõr brand. Fõr 
att undvika detta skall vid anslutning av 
utrustningen till kabel-TV nät galvanisk isolator 
finnas mellan utrustningen och kabel-TV nätet." 
           
2.3.2
 
 
            Requirements according to this annex, 
6.1.2.1 and 6.1.2.2 apply. 
           
 
             
           
N/A
 
2.10.5.13
 
 
            Requirements according to this annex, 
6.1.2.1 and 6.1.2.2 apply. 
           
 
             
           
N/A
 
5.1.7.1
 
 
            TOUCH CURRENT measurement results 
exceeding 3,5 mA r.m.s are permitted only for the 
following equipment: 
STATIONARY PLUGGABLE EQUIPMENT TYPE A 
that:  
(1) is intended to be used in a RESTRICTED 
ACCESS LOCATION where equipotential bonding 
has been applied, for example, in a 
telecommunication centre; and  
(2) has provision for a permanently connected 
PROTECTIVE EARTHING CONDUCTOR; and  
(3) is provided with instructions for the installation 
of that conductor by a SERVICE PERSON; 
- STATIONARY PLUGGABLE TYPE B 
- STATIONARY PERMANENTLY CONNECTED 
EQUIPMENT 
           
 
             
           
N/A
 