JBL ON BEAT MICRO (serv.man3) EMC - CB Certificate ▷ View online
Issue Date:
2012-10-23
Page 35 of 41
Report Reference #
E204594-A37-CB-1
IEC 60950-1:2005
SubClause Difference + Test
Result - Remark
Verdict
This report issued under the responsibility of UL
3.4.2
Separate motor control device(s) required
for cord-connected equipment rated more than 12
A, or with motor rated more than 1/3 hp or more
than 120 V.
N/A
3.4.8
Vertically mounted disconnect devices
oriented so up position of handle is "on".
N/A
3.4.11
For computer-room applications, equipment
with battery systems capable of supplying 750 VA
for 5 min require battery disconnect means.
N/A
4.2.8.1
Special opening restrictions for enclosures
around CRTs with face dimension of 160 mm or
more.
N/A
4.2.9
Compartment housing high-pressure lamp
marked to indicate risk of explosion.
N/A
4.2.11
For equipment intended for mounting on
racks and provided with slide/rails allowing the
equipment to slide away from the rack for
installation, service and maintenance, additional
construction, performance and marking
requirements are applicable to determine the
adequacy of the slide/rails.
N/A
4.3.2
Loading test for equipment with handle(s)
used to support more than 9 kg tested at four times
the weight of the unit.
N/A
4.3.6
In addition to the IEC requirements, Direct
Plug-in Equipment complies with UL 1310 or CSA
223 mechanical assembly requirements.
N/A
4.3.12
N/A
Issue Date:
2012-10-23
Page 36 of 41
Report Reference #
E204594-A37-CB-1
IEC 60950-1:2005
SubClause Difference + Test
Result - Remark
Verdict
This report issued under the responsibility of UL
The maximum quantity of flammable liquid
stored in equipment complies with ANSI/NFPA
30(Table NAE.6).
stored in equipment complies with ANSI/NFPA
30(Table NAE.6).
4.3.12
Equipment using replenishable liquids
marked to indicate type of liquid to be used.
N/A
4.3.13.2
Equipment that produces x-radiation and
does not comply with 4.3.12 under all conditions of
servicing marked to indicate the presence of
radiation where readily visible.
N/A
4.3.13.5
Requirements contained in the applicable
national codes and regulations apply to lasers (21
CFR 1040 and REDR C1370).
N/A
4.7
Automated information storage equipment
intended to contain more than 0.76 m³ of
combustible media requires provision for automatic
sprinklers or a gaseous agent extinguishing
system.
N/A
4.7.3.1
Equipment for use in environmental air
space other than ducts or plenums provided with
metal enclosure or with non-metallic enclosure
having adequate fire-resistance and low smoke
producing characteristics. Low smoke-producing
characteristics evaluated according to UL 2043.
Equipment for installation in space used for
environmental air as described in Sec. 300-22(c) of
the NEC provided with instructions indicating
suitability for installation in such locations.
N/A
4.7.3.1
Flame spread rating for external surface of
combustible material with exposed area greater
than 0.93 m² or a single dimension greater than 1.8
m; 50 or less for computer room applications or
200 or less for other applications.
N/A
Issue Date:
2012-10-23
Page 37 of 41
Report Reference #
E204594-A37-CB-1
IEC 60950-1:2005
SubClause Difference + Test
Result - Remark
Verdict
This report issued under the responsibility of UL
4.7.3.4
Wire marked "VW-1" or "FT-1" considered
equivalent.
Pass
5.1.8.2
Special earthing provisions and instructions
for equipment with high touch current due to
telecommunication network connections.
N/A
5.1.8.3
Touch current due to ringing voltage for
equipment containing telecommunication network
leads.
N/A
5.3.7
Overloading of SELV connectors and
printed wiring board receptacles accessible to the
operator.
N/A
5.3.7
Tests interrupted by opening of a
component repeated two additional times.
N/A
5.3.9.1
Test interrupted by opening of wire or trace
subject to certain conditions.
N/A
6
Specialized instructions provided for
telephones that may be connected to a
telecommunications network.
N/A
6
Marking identifying function of
telecommunication type connectors not used for
connection to a telecommunication network.
N/A
6.3
Equipment remotely powered over
telecommunication wiring systems provided with
specialized markings adjacent to the connection.
N/A
6.3
Overcurrent protection incorporated into
N/A
Issue Date:
2012-10-23
Page 38 of 41
Report Reference #
E204594-A37-CB-1
IEC 60950-1:2005
SubClause Difference + Test
Result - Remark
Verdict
This report issued under the responsibility of UL
equipment to provide power over
telecommunication wiring system not
interchangeable with devices of higher ratings if
operator replaceable.
telecommunication wiring system not
interchangeable with devices of higher ratings if
operator replaceable.
6.4
Additional requirements for equipment
intended for connection to a telecommunication
network using cable subject to overvoltage from
power line failures (Fig. 6C).
N/A
6.4
Where 26 AWG line cord required by Fig.
6C, either the cord is provided with the equipment
or described in the safety instructions.
N/A
7
Equipment associated with the cable
distribution system may need to be subjected to
applicable parts of Chapter 8 of the NEC.
N/A
H
Ionizing radiation measurements made
under single fault conditions in accordance with the
requirements of the Code of Federal Regulations
21 CFR 1020 and the Canadian Radiation Emitting
Devices Act, REDR C1370.
N/A
M.2
Continuous ringing signals evaluated to
Method A subjected to special accessibility
considerations.
N/A
M.4
Special requirements for message waiting
and similar telecommunications signals.
N/A
NAC
Equipment intended for use with a generic
secondary protector marked with suitable
instructions.
N/A
NAC
Equipment intended for use with a specific
N/A