JBL ON BEAT MICRO (serv.man3) EMC - CB Certificate ▷ View online
Issue Date:
2012-10-23
Page 39 of 41
Report Reference #
E204594-A37-CB-1
IEC 60950-1:2005
SubClause Difference + Test
Result - Remark
Verdict
This report issued under the responsibility of UL
primary or secondary protector marked with
suitable instructions.
suitable instructions.
NAD
Acoustic pressure from an ear piece less
than 140 dBA for short duration disturbances, and
less than 125 dBA for handsets, 118 dBA for
headsets and insert earphones, for long duration
disturbances.
N/A
NAD
Equipment connected to a
telecommunication and cable distribution networks
and supplied with an earphone intended to be held
against, or in the ear is required to comply with
special acoustic pressure requirements.
N/A
EE.5
UL articulated accessibility probe (Fig.
EE.3) required for assessing accessibility to
document/media shredders, instead of Figure 2A
test finger.
N/A
Issue Date:
2012-10-23
Page 40 of 41
Report Reference #
E204594-A37-CB-1
IEC 60950-1:2005
SubClause Difference + Test
Result - Remark
Verdict
This report issued under the responsibility of UL
United Kingdom - Differences to IEC 60950-1:2005 (2nd Edition); Am 1:2009
2.6.3.3
The current rating of the circuit shall be
taken as 13 A, not 16 A.
N/A
2.7.1
To protect against excessive currents and
short-circuits in the PRIMARY CIRCUIT of DIRECT
PLUG-IN EQUIPMENT, tests according to 5.3 shall
be conducted, using an external protective device
rated 30 A or 32 A. If these tests fail, suitable
protective devices shall be included as integral
parts of the DIRECT PLUG-IN EQUIPMENT, so
that the requirements of 5.3 are met.
N/A
3.2.1.1
Apparatus which is fitted with a flexible
cable or cord and is designed to be connected to a
mains socket conforming to BS 1363 by means of
that flexible cable or cord and plug, shall be fitted
with a "standard plug" in accordance with Statutory
Instrument 1786: 1994 - The Plugs and Sockets
etc. (Safety) Regulations 1994, unless exempted
by those regulations.
NOTE: "Standard plug" is defined in SI 1786: 1994
and essentially means an approved plug
conforming to BS 1363 or an approved conversion
plug.
N/A
3.2.5.1
A power supply cord with conductor of 1.25
mm² is allowed for equipment with a rated current
over 10A and up to and including 13A.
N/A
3.3.4
The range of conductor sizes of flexible
cords to be accepted by terminals for equipment
with a rated current of over 10 A up to and
including 13 A is 1.25 mm² to 1.5 mm² nominal
cross-sectional area.
N/A
4.3.6
The torque test is performed using a socket
outlet complying with BS 1363 part 1:1995,
N/A
Issue Date:
2012-10-23
Page 41 of 41
Report Reference #
E204594-A37-CB-1
IEC 60950-1:2005
SubClause Difference + Test
Result - Remark
Verdict
This report issued under the responsibility of UL
including Amendment 1:1997 and Amendment
2:2003 and the plug part of DIRECT PLUG-IN
EQUIPMENT shall be assessed to BS 1363: Part
1, 12.1, 12.2, 12.3, 12.9, 12.11, 12.12, 12.13, 12.16
and 12.17, except that the test of 12.17 is
performed at not less than 125 °C. Where the
metal earth pin is replaced by an Insulated Shutter
Opening Device (ISOD), the requirements of
clauses 22.2 and 23 also apply.
2:2003 and the plug part of DIRECT PLUG-IN
EQUIPMENT shall be assessed to BS 1363: Part
1, 12.1, 12.2, 12.3, 12.9, 12.11, 12.12, 12.13, 12.16
and 12.17, except that the test of 12.17 is
performed at not less than 125 °C. Where the
metal earth pin is replaced by an Insulated Shutter
Opening Device (ISOD), the requirements of
clauses 22.2 and 23 also apply.
Issue Date:
2012-10-23
Page 1 of 8
Report Reference #
E204594-A37-CB-1
Enclosures
This report issued under the responsibility of UL
Enclosures
Type
Supplement Id
Description
Photographs
3-01
Front
Photographs
3-02
Bottom
Photographs
3-03
Bottom with Battery Cover removed
Photographs
3-04
Diagrams
Schematics + PWB
Manuals
Miscellaneous
7-01
Letter of Assurance
Licenses
8-01
Power Supply Cert.
Marking Plate
Click on the first or last page to see other ON BEAT MICRO (serv.man3) service manuals if exist.