JBL ON BEAT MICRO (serv.man3) EMC - CB Certificate ▷ View online

Issue Date: 
2012-10-23 
Page 49 of 50 
Report Reference # 
E204594-A37-CB-1 
 
 
 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. : IEC60950_1B 
This report issued under the responsibility of UL 
  
Basic/supplementary:  
Test voltage applied between: 
Voltage shape 
(AC, DC, 
impulse, surge)  
Test voltage 
(V)  
Breakdown 
Yes / No  
 
 
 
 
Reinforced:  
Test voltage applied between: 
Voltage shape 
(AC, DC, 
impulse, surge)  
Test voltage 
(V)  
Breakdown 
Yes / No  
 
 
 
 
supplementary information:  
 
 
5.3  
TABLE: fault condition tests  
Pass 
 
ambient temperature ( ° C) .....................................  :   - 
— 
 
Power source for EUT: Manufacturer, model/type, 
output rating ............................................................  :  
Kuantech Co., Ltd., Model 
KSAS0250059033D5, 
100-240V AC, 50/60Hz 0.9 A 
O/P: 5.9 Vdc, 3.3 A 
— 
Component 
No.  
Fault  
Supply 
voltage 
(V)  
Test time 
Fuse 
Fuse current 
(A)  
Observation  
IPhone5 
port 
Overload 
6 Vdc 
1 hr. 
Open Circuit Voltage 5.00 
Vdc; Maximum Available 
Current, 1.24 A.  NC, NT, 
CT 
USB Port 
Overload 
6 Vdc 
1 hr. 
Open Circuit Voltage 4.98 
Vdc; Maximum Available 
Current, 1.24 A.  NC, NT, 
CT 
supplementary information:  
 
Issue Date: 
2012-10-23 
Page 50 of 50 
Report Reference # 
E204594-A37-CB-1 
 
 
 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. : IEC60950_1B 
This report issued under the responsibility of UL 
  
C.2  
TABLE: transformers  
N/A 
Loc.  
Tested 
insulation  
Working 
voltage 
peak /V  
(2.10.2)  
Working 
voltage 
rms /V  
(2.10.2)  
Required 
electric 
strength  
(5.2)  
Required 
clearance / 
mm  
(2.10.3)  
Required 
creepage 
distance / 
mm  
(2.10.4)  
Required 
distance 
thr. insul.  
(2.10.5)  
 
 
 
 
 
 
 
 
Loc.  
Tested insulation  
Test 
voltage / V  
Measured 
clearance / 
mm  
Measured 
creepage 
dist./mm  
Measured 
distance 
thr. insul / 
mm; 
number of 
layers  
 
 
 
 
 
 
Transformer type number  
Enclosure - Miscellaneous ID  
 
 
supplementary information:  
 
 
 
Issue Date: 
2012-10-23 
Page 1 of 41 
Report Reference # 
E204594-A37-CB-1 
 
 
 
 
 
 
This report issued under the responsibility of UL 
  
Enclosure
  
National Differences
  
 
Austria** 
Belgium** 
Bulgaria** 
China* 
Czech Republic** 
Denmark 
Finland 
France** 
Germany 
Greece** 
Group 
Hungary** 
Ireland 
Israel 
Italy** 
Japan* 
Korea 
Netherlands** 
Norway 
Poland** 
Portugal** 
Romania** 
Singapore* 
Slovakia** 
Slovenia** 
Spain 
Sweden 
Switzerland 
USA / Canada 
Ukraine* 
United Kingdom 
 
 
*
 
No National Differences Declared
 
**  Only Group Differences 
 
 
Issue Date: 
2012-10-23 
Page 2 of 41 
Report Reference # 
E204594-A37-CB-1 
 
 
 
 
 
IEC 60950-1:2005 
SubClause  Difference + Test 
Result - Remark 
Verdict 
 
 
This report issued under the responsibility of UL 
  
Denmark - Differences to IEC 60950-1:2005 (2nd Edition); Am 1:2009 
 
 
1.2.4.1
 
 
            In Denmark, certain types of Class I 
appliances (see sub-clause 3.2.1.1) may be 
provided with plug not establishing earthing 
continuity when inserted into Danish socket-outlets. 
           
 
             
           
N/A
 
1.7.5
 
 
            In Denmark, socket-outlets for providing 
power to other equipment shall be in accordance 
with the Heavy Current Regulations, Section 107-2-
D1, Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a, 
when used on Class I equipment.  For stationary 
equipment, the socket-outlet shall be in accordance 
with Standard Sheet DK 1-1b or DK 1-5a. 
           
 
             
           
N/A
 
1.7.5
 
 
            For CLASS II EQUIPMENT the socket 
outlet shall be in accordance with Standard Sheet 
DKA 1-4a. (Heavy Current Regulations, Section 
107-2-D1) 
           
 
             
           
N/A
 
3.2.1.1
 
 
            Supply cord of single-phase equipment 
having a rated current not exceeding 13 A shall be 
provided with a plug according to the Heavy 
Current Regulations, Section 107-2-D1. 
 
CLASS I EQUIPMENT provided with socket-outlets 
with earth contact or which are intended to be used 
in locations where protection against indirect 
contact is required according to the wiring rules 
shall be provided with a plug in accordance with 
standard sheet DK 2-1a or DK 2-5a. 
 
If poly-phase equipment and single-phase 
equipment having a RATED CURRENT exceeding 
13 A is provided with a supply cord with a plug, this 
plug shall be in accordance with the Heavy Current 
Regulations, Section 107-2-D1 or EN 60309-2. 
           
 
             
           
N/A
 
 