JBL ON BEAT MICRO (serv.man3) EMC - CB Certificate ▷ View online
Issue Date:
2012-10-23
Page 3 of 41
Report Reference #
E204594-A37-CB-1
IEC 60950-1:2005
SubClause Difference + Test
Result - Remark
Verdict
This report issued under the responsibility of UL
Finland - Differences to IEC 60950-1:2005 (2nd Edition); Am 1:2009
1.5.7.1
Resistors bridging BASIC INSULATION in
CLASS I PLUGGABLE EQUIPMENT TYPE A must
comply with the requirements in 1.5.7.1. In
addition when a single resistor is used, the resistor
must withstand the resistor test in 1.5.7.2.
N/A
1.5.9.4
The third dashed sentence is applicable
only to equipment as defined by annex, 6.1.2.2.
N/A
1.7.2.1
CLASS I PLUGGABLE EQUIPMENT TYPE
A intended for connection to other equipment or a
network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
accessible parts, have a marking stating that the
equipment must be connected to an earthed mains
socket-outlet. The marking text shall be: "Laite on
liitettävä suojakoskettimilla varustettuun
pistorasiaan"
N/A
2.3.2
Requirements according to this annex
6.1.2.1 and 6.1.2.2 apply.
N/A
2.10.5.13
Requirements according to this annex
6.1.2.1 and 6.1.2.2 apply.
N/A
5.1.7.1
Touch current measurement results
exceeding 3,5 mA r.m.s are permitted only for the
following equipment:
- STATIONARY PLUGGABLE EQUIPMENT TYPE
A that:
(1) is intended to be used in a RESTRICTED
ACCESS LOCATION where equipotential bonding
has been applied, for example, in a
telecommunication centre; and
(2) has provision for a permanently connected
PROTECTIVE EARTHING CONDUCTOR; and
(3) is provided with instructions for the installation
N/A
Issue Date:
2012-10-23
Page 4 of 41
Report Reference #
E204594-A37-CB-1
IEC 60950-1:2005
SubClause Difference + Test
Result - Remark
Verdict
This report issued under the responsibility of UL
of that conductor by a SERVICE PERSON;
- STATIONARY PLUGGABLE EQUIPMENT TYPE
B
- STATIONARY PERMANENTLY CONNECTED
EQUIPMENT
- STATIONARY PLUGGABLE EQUIPMENT TYPE
B
- STATIONARY PERMANENTLY CONNECTED
EQUIPMENT
6.1.2.1
Add the following text between the first and
second paragraph of the compliance clause:
If this insulation is solid, including insulation
forming part of a component, it shall at least consist
of either
- two layers of thin sheet material, each of which
shall pass the electric strength test below, or
- one layer having a distance through insulation of
at least 0,4 mm, which shall pass the electric
strength test below.
Alternatively for components, there is no distance
through insulation requirement for the insulation
consisting of an insulating compound completely
filling the casing, so that CLEARANCES and
CREEPAGE DISTANCES do not exist, if the
component passes the electric strength test in
accordance with the compliance clause below and
in addition
- passes the tests and inspection criteria of 2.10.11
with an electric strength test of 1,5 kV multiplied by
1,6 (the electric strength test of 2.10.10 shall be
performed using 1,5 kV), and
- is subject to ROUTINE TESTING for electric
strength during manufacturing, using a test voltage
of 1,5 kV.
It is permitted to bridge this insulation with an
optocoupler complying with 2.10.5.4 b).
It is permitted to bridge this insulation with a
capacitor complying with EN 132400:1994 (EN
60384-14:2005), subclass Y2.
A capacitor classified Y3 according to EN 132400
[EN 60384-14:2005], may bridge this insulation
under the following conditions:
- the insulation requirements are satisfied by
having a capacitor classified Y3 as defined by EN
132400 [EN 60384-14], which in addition to the Y3
testing, is tested with an impulse test of 2,5 kV
N/A
Issue Date:
2012-10-23
Page 5 of 41
Report Reference #
E204594-A37-CB-1
IEC 60950-1:2005
SubClause Difference + Test
Result - Remark
Verdict
This report issued under the responsibility of UL
defined in EN 60950-1:2006, 6.2.2.1;
- the additional testing shall be performed on all the
test specimens as described in EN 132400 [EN
60384-14];
- the impulse test of 2,5 kV is to be performed
before the endurance test in EN 132400 [EN
60384-14], in the sequence of tests as described in
EN 132400 [EN 60384-14].
- the additional testing shall be performed on all the
test specimens as described in EN 132400 [EN
60384-14];
- the impulse test of 2,5 kV is to be performed
before the endurance test in EN 132400 [EN
60384-14], in the sequence of tests as described in
EN 132400 [EN 60384-14].
6.1.2.2
The exclusions are applicable for
PERMANENTLY CONNECTED EQUIPMENT,
PLUGGABLE EQUIPMENT TYPE B and
equipment intended to be used in a RESTRICTED
ACCESS LOCATION where equipotential bonding
has been applied, e.g. in a telecommunication
center, and which has provision for a permanently
connected PROTECTIVE EARTHING
CONDUCTOR and is provided with instructions for
the installation of that conductor by a SERVICE
PERSON.
N/A
7.2
Requirements according to this annex
6.1.2.1 and 6.1.2.2 apply with the term
TELECOMMUNICATION NETWORK in 6.1.2
being replaced by the term CABLE DISTRIBUTION
SYSTEM.
N/A
Germany - Differences to IEC 60950-1:2005 (2nd Edition); Am 1:2009
1.7.2.1
According to GPSG, section 2, clause 4: If
certain rules on the use, supplementation or
maintenance of an item of technical work
equipment or ready-to-use commodity must be
observed in order to guarantee safety and health,
instructions for use in German must be supplied
when it is brought into circulation.
See enclosure 7-01
Pass
Issue Date:
2012-10-23
Page 6 of 41
Report Reference #
E204594-A37-CB-1
IEC 60950-1:2005
SubClause Difference + Test
Result - Remark
Verdict
This report issued under the responsibility of UL
Group - Differences to IEC 60950-1:2005 (2nd Edition); Am 1:2009
1.1.1
Replace the text of NOTE 3 by the
following:
NOTE 3 The requirements of EN60065 may also
be used to meet safety requirements for multimedia
equipment. See IEC Guide 112, Guide on the
Safety of Multimedia Equipment. For television
sets, EN60065 applies.
N/A
1.2.3
Add the following definition.
1.2.3.Z1 Portable Sound System
Small battery powered audio equipment
-whose prime purpose is to listen to recorded or
boardcasted sound; and
-that uses headphones or earphones that can be
worn in or on or around the ears; and
-that allows the user to walk around
NOTE: Examples are mini-disk or CD players, MP3
audio players or similar equipment.
N/A
1.5.1
Add the following NOTE Z1: The use of
certain substances in electrical and electronic
equipment is restricted within the EU: see Directive
2002/95/EC
Pass
1.7.2.1
Delete NOTE Z1 and addd the following
paragraph at the end of the subclause:
In addition, for a PORTABLE SOUND SYSTEM,
the instructions shall include a a warning that
excessive sound pressure from earphones and
headphones can cause hearing loss.
N/A
2.7.1
Replace the subclause as follows:
Basic requirements
To protect against excessive current, short-circuits
and earth faults in PRIMARY CIRCUITS, protective
devices shall be included either as integral parts of
the equipment or as parts of the building
installation, subject to the following, a), b) and c):
a) except as detailed in b) and c), protective
devices necessary to comply with the requirements
N/A
Click on the first or last page to see other ON BEAT MICRO (serv.man3) service manuals if exist.