JBL ON BEAT MICRO (serv.man3) EMC - CB Certificate ▷ View online

Issue Date: 
2012-10-23 
Page 3 of 41 
Report Reference # 
E204594-A37-CB-1 
 
 
 
 
 
IEC 60950-1:2005 
SubClause  Difference + Test 
Result - Remark 
Verdict 
 
 
This report issued under the responsibility of UL 
  
Finland - Differences to IEC 60950-1:2005 (2nd Edition); Am 1:2009 
 
 
1.5.7.1
 
 
            Resistors bridging BASIC INSULATION in 
CLASS I PLUGGABLE EQUIPMENT TYPE A must 
comply with the requirements in 1.5.7.1.  In 
addition when a single resistor is used, the resistor 
must withstand the resistor test in 1.5.7.2. 
           
 
             
           
N/A
 
1.5.9.4
 
 
            The third dashed sentence is applicable 
only to equipment as defined by annex, 6.1.2.2. 
           
 
             
           
N/A
 
1.7.2.1
 
 
            CLASS I PLUGGABLE EQUIPMENT TYPE 
A intended for connection to other equipment or a 
network shall, if safety relies on connection to 
protective earth or if surge suppressors are 
connected between the network terminals and 
accessible parts, have a marking stating that the 
equipment must be connected to an earthed mains 
socket-outlet.  The marking text shall be: "Laite on 
liitettävä suojakoskettimilla varustettuun 
pistorasiaan" 
           
 
             
           
N/A
 
2.3.2
 
 
            Requirements according to this annex 
6.1.2.1 and 6.1.2.2 apply. 
           
 
             
           
N/A
 
2.10.5.13
 
 
            Requirements according to this annex 
6.1.2.1 and 6.1.2.2 apply. 
           
 
             
           
N/A
 
5.1.7.1
 
 
            Touch current measurement results 
exceeding 3,5 mA r.m.s are permitted only for the 
following equipment: 
- STATIONARY PLUGGABLE EQUIPMENT TYPE 
A that:  
(1) is intended to be used in a RESTRICTED 
ACCESS LOCATION where equipotential bonding 
has been applied, for example, in a 
telecommunication centre; and  
(2) has provision for a permanently connected 
PROTECTIVE EARTHING CONDUCTOR; and  
(3) is provided with instructions for the installation 
 
             
           
N/A
 
Issue Date: 
2012-10-23 
Page 4 of 41 
Report Reference # 
E204594-A37-CB-1 
 
 
 
 
 
IEC 60950-1:2005 
SubClause  Difference + Test 
Result - Remark 
Verdict 
 
 
This report issued under the responsibility of UL 
  
of that conductor by a SERVICE PERSON; 
- STATIONARY PLUGGABLE EQUIPMENT TYPE 

- STATIONARY PERMANENTLY CONNECTED 
EQUIPMENT 
           
6.1.2.1
 
 
            Add the following text between the first and 
second paragraph of the compliance clause: 
If this insulation is solid, including insulation 
forming part of a component, it shall at least consist 
of either 
- two layers of thin sheet material, each of which 
shall pass the electric strength test below, or 
- one layer having a distance through insulation of 
at least 0,4 mm, which shall pass the electric 
strength test below. 
 
Alternatively for components, there is no distance 
through insulation requirement for the insulation 
consisting of an insulating compound completely 
filling the casing, so that CLEARANCES and 
CREEPAGE DISTANCES do not exist, if the 
component passes the electric strength test in 
accordance with the compliance clause below and 
in addition 
- passes the tests and inspection criteria of 2.10.11 
with an electric strength test of 1,5 kV multiplied by 
1,6 (the electric strength test of 2.10.10 shall be 
performed using 1,5 kV), and 
- is subject to ROUTINE TESTING for electric 
strength during manufacturing, using a test voltage 
of 1,5 kV. 
 
It is permitted to bridge this insulation with an 
optocoupler complying with 2.10.5.4 b). 
 
It is permitted to bridge this insulation with a 
capacitor complying with EN 132400:1994 (EN 
60384-14:2005), subclass Y2. 
A capacitor classified Y3 according to EN 132400 
[EN 60384-14:2005], may bridge this insulation 
under the following conditions: 
- the insulation requirements are satisfied by 
having a capacitor classified Y3 as defined by EN 
132400 [EN 60384-14], which in addition to the Y3 
testing, is tested with an impulse test of 2,5 kV 
 
             
           
N/A
 
Issue Date: 
2012-10-23 
Page 5 of 41 
Report Reference # 
E204594-A37-CB-1 
 
 
 
 
 
IEC 60950-1:2005 
SubClause  Difference + Test 
Result - Remark 
Verdict 
 
 
This report issued under the responsibility of UL 
  
defined in EN 60950-1:2006, 6.2.2.1; 
- the additional testing shall be performed on all the 
test specimens as described in EN 132400 [EN 
60384-14]; 
- the impulse test of 2,5 kV is to be performed 
before the endurance test in EN 132400 [EN 
60384-14], in the sequence of tests as described in 
EN 132400 [EN 60384-14]. 
           
6.1.2.2
 
 
            The exclusions are applicable for 
PERMANENTLY CONNECTED EQUIPMENT, 
PLUGGABLE EQUIPMENT TYPE B and 
equipment intended to be used in a RESTRICTED 
ACCESS LOCATION where equipotential bonding 
has been applied, e.g. in a telecommunication 
center, and which has provision for a permanently 
connected PROTECTIVE EARTHING 
CONDUCTOR and is provided with instructions for 
the installation of that conductor by a SERVICE 
PERSON. 
           
 
             
           
N/A
 
7.2
 
 
            Requirements according to this annex 
6.1.2.1 and 6.1.2.2 apply with the term 
TELECOMMUNICATION NETWORK in 6.1.2 
being replaced by the term CABLE DISTRIBUTION 
SYSTEM. 
           
 
             
           
N/A
 
 
Germany - Differences to IEC 60950-1:2005 (2nd Edition); Am 1:2009 
 
 
1.7.2.1
 
 
            According to GPSG, section 2, clause 4:  If 
certain rules on the use, supplementation or 
maintenance of an item of technical work 
equipment or ready-to-use commodity must be 
observed in order to guarantee safety and health, 
instructions for use in German must be supplied 
when it is brought into circulation. 
           
 
            See enclosure 7-01 
           
Pass
 
 
Issue Date: 
2012-10-23 
Page 6 of 41 
Report Reference # 
E204594-A37-CB-1 
 
 
 
 
 
IEC 60950-1:2005 
SubClause  Difference + Test 
Result - Remark 
Verdict 
 
 
This report issued under the responsibility of UL 
  
Group - Differences to IEC 60950-1:2005 (2nd Edition); Am 1:2009 
 
 
1.1.1
 
 
            Replace the text of NOTE 3 by the 
following: 
NOTE 3  The requirements of EN60065 may also 
be used to meet safety requirements for multimedia 
equipment.  See IEC Guide 112, Guide on the 
Safety of Multimedia Equipment.  For television 
sets, EN60065 applies. 
           
 
             
           
N/A
 
1.2.3
 
 
            Add the following definition. 
1.2.3.Z1  Portable Sound System 
Small battery powered audio equipment 
-whose prime purpose is to listen to recorded or 
boardcasted sound; and 
-that uses headphones or earphones that can be 
worn in or on or around the ears; and 
-that allows the user to walk around 
NOTE: Examples are mini-disk or CD players, MP3 
audio players or similar equipment. 
           
 
             
           
N/A
 
1.5.1
 
 
            Add the following NOTE Z1: The use of 
certain substances in electrical and electronic 
equipment is restricted within the EU: see Directive 
2002/95/EC 
           
 
             
           
Pass
 
1.7.2.1
 
 
            Delete NOTE Z1 and addd the following 
paragraph at the end of the subclause: 
In addition, for a PORTABLE SOUND SYSTEM, 
the instructions shall include a a warning that 
excessive sound pressure from earphones and 
headphones can cause hearing loss. 
           
 
             
           
N/A
 
2.7.1
 
 
            Replace the subclause as follows: 
Basic requirements 
To protect against excessive current, short-circuits 
and earth faults in PRIMARY CIRCUITS, protective 
devices shall be included either as integral parts of 
the equipment or as parts of the building 
installation, subject to the following, a), b) and c): 
a) except as detailed in b) and c), protective 
devices necessary to comply with the requirements 
 
             
           
N/A
 
Page of 99