JBL ON BEAT MICRO (serv.man3) EMC - CB Certificate ▷ View online
Issue Date:
2012-10-23
Page 29 of 50
Report Reference #
E204594-A37-CB-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. : IEC60950_1B
This report issued under the responsibility of UL
4.6
Openings in enclosures
N/A
4.6.1
Top and side openings
N/A
Dimensions (mm) .................................................. :
-
4.6.2
Bottoms of fire enclosures
N/A
Construction of the bottom, dimensions (mm)....... :
-
4.6.3
Doors or covers in fire enclosures
N/A
4.6.4
Openings in transportable equipment
N/A
4.6.4.1
Constructional design measures
N/A
Dimensions (mm) .................................................. :
-
4.6.4.2
Evaluation measures for larger openings
N/A
4.6.4.3
Use of metallized parts
N/A
4.6.5
Adhesives for constructional purposes
N/A
Conditioning temperature (°C), time (weeks) ........ :
-
4.7
Resistance to fire
Pass
4.7.1
Reducing the risk of ignition and spread of flame
Use of materials with the
required flammability classes.
required flammability classes.
Pass
Method 1, selection and application of components
wiring and materials
wiring and materials
Pass
Method 2, application of all of simulated fault
condition tests
condition tests
N/A
4.7.2
Conditions for a fire enclosure
Pass
4.7.2.1
Parts requiring a fire enclosure
N/A
4.7.2.2
Parts not requiring a fire enclosure
PWB minimum V-1.
Pass
4.7.3
Materials
Pass
4.7.3.1
General
Pass
4.7.3.2
Materials for fire enclosures
N/A
4.7.3.3
Materials for components and other parts outside
fire enclosures
fire enclosures
N/A
4.7.3.4
Materials for components and other parts inside fire
enclosures
enclosures
N/A
4.7.3.5
Materials for air filter assemblies
N/A
4.7.3.6
Materials used in high-voltage components
N/A
Issue Date:
2012-10-23
Page 30 of 50
Report Reference #
E204594-A37-CB-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. : IEC60950_1B
This report issued under the responsibility of UL
5
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS
Pass
5.1
Touch current and protective conductor current
N/A
5.1.1
General
Unit supplied by SELV circuits.
N/A
5.1.2
Configuration of equipment under test (EUT)
N/A
5.1.2.1
Single connection to an a.c. mains supply
N/A
5.1.2.2
Redundant multiple connections to an a.c. mains
supply
supply
N/A
5.1.2.3
Simultaneous multiple connections to an a.c. mains
supply
supply
N/A
5.1.3
Test circuit
N/A
5.1.4
Application of measuring instrument
N/A
5.1.5
Test procedure
N/A
5.1.6
Test measurements
N/A
Supply voltage (V) ................................................. :
-
Measured touch current (mA) ................................ :
-
Max. allowed touch current (mA) ........................... :
-
Measured protective conductor current (mA) ........ :
-
Max. allowed protective conductor current (mA) ... :
-
5.1.7
Equipment with touch current exceeding 3,5 mA
N/A
5.1.7.1
General .................................................................. :
N/A
5.1.7.2
Simultaneous multiple connections to the supply
N/A
5.1.8
Touch currents to telecommunication networks and
cable distribution systems and from
telecommunication networks
cable distribution systems and from
telecommunication networks
N/A
5.1.8.1
Limitation of the touch current to a
telecommunication network or to a cable
distribution system
telecommunication network or to a cable
distribution system
N/A
Supply voltage (V) ................................................. :
-
Measured touch current (mA) ................................ :
-
Max. allowed touch current (mA) ........................... :
-
5.1.8.2
Summation of touch currents from
telecommunication networks
telecommunication networks
N/A
a) EUT with earthed telecommunication ports ...... :
N/A
b) EUT whose telecommunication ports have no
reference to protective earth
reference to protective earth
N/A
Issue Date:
2012-10-23
Page 31 of 50
Report Reference #
E204594-A37-CB-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. : IEC60950_1B
This report issued under the responsibility of UL
5.2
Electric strength
N/A
5.2.1
General
N/A
5.2.2
Test procedure
N/A
5.3
Abnormal operating and fault conditions
Pass
5.3.1
Protection against overload and abnormal
operation
operation
N/A
5.3.2
Motors
N/A
5.3.3
Transformers
N/A
5.3.4
Functional insulation .............................................. :
Components mounted on
minimum V1 PWB.
minimum V1 PWB.
Pass
5.3.5
Electromechanical components
N/A
5.3.6
Audio amplifiers in ITE ........................................... :
N/A
5.3.7
Simulation of faults
N/A
5.3.8
Unattended equipment
N/A
5.3.9
Compliance criteria for abnormal operating and
fault conditions
fault conditions
N/A
5.3.9.1
During the tests
N/A
5.3.9.2
After the tests
N/A
6
CONNECTION TO TELECOMMUNICATION NETWORKS
N/A
6.1
Protection of telecommunication network service persons, and users of other
equipment connected to the network, from hazards in the equipment
equipment connected to the network, from hazards in the equipment
N/A
6.1.1
Protection from hazardous voltages
N/A
6.1.2
Separation of the telecommunication network from earth
N/A
6.1.2.1
Requirements
N/A
Supply voltage (V) ................................................. :
-
Current in the test circuit (mA) ............................... :
-
6.1.2.2
Exclusions.............................................................. :
N/A
Issue Date:
2012-10-23
Page 32 of 50
Report Reference #
E204594-A37-CB-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. : IEC60950_1B
This report issued under the responsibility of UL
6.2
Protection of equipment users from overvoltages on telecommunication
networks
networks
N/A
6.2.1
Separation requirements
N/A
6.2.2
Electric strength test procedure
N/A
6.2.2.1
Impulse test
N/A
6.2.2.2
Steady-state test
N/A
6.2.2.3
Compliance criteria
N/A
6.3
Protection of the telecommunication wiring system from overheating
N/A
Max. output current (A) .......................................... :
-
Current limiting method ......................................... :
-
7
CONNECTION TO CABLE DISTRIBUTION SYSTEMS
N/A
7.1
General
N/A
7.2
Protection of cable distribution system service
persons, and users of other equipment connected
to the system, from hazardous voltages in the
equipment
persons, and users of other equipment connected
to the system, from hazardous voltages in the
equipment
N/A
7.3
Protection of equipment users from overvoltages
on the cable distribution system
on the cable distribution system
N/A
7.4
Insulation between primary circuits and cable
distribution systems
distribution systems
N/A
7.4.1
General
N/A
7.4.2
Voltage surge test
N/A
7.4.3
Impulse test
N/A
Click on the first or last page to see other ON BEAT MICRO (serv.man3) service manuals if exist.