JBL FLIP II (serv.man6) EMC - CB Certificate ▷ View online

 
Page 23 of 88                        Report No. EFSN13070129E-1 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1C 
 
 
4.5.3 
Temperature limits for materials 
(see appended table 4.5) 
4.5.4 
Touch temperature limits 
(see appended table 4.5) 
4.5.5 
Resistance to abnormal heat  ............................... : 
 
N/A 
 
4.6 
Openings in enclosures 
4.6.1 
Top and side openings 
No any opening 
P 
 
Dimensions (mm)  ................................................. : 
 
 
4.6.2 
Bottoms of fire enclosures 
No any opening 
 
Construction of the bottomm, dimensions (mm)  .. : 
 
 
4.6.3 
Doors or covers in fire enclosures 
No doors or covers. 
N/A 
4.6.4 
Openings in transportable equipment 
Not transportable equipment. 
N/A 
4.6.4.1 
Constructional design measures 
 
N/A 
 
Dimensions (mm)  ................................................. : 
 
 
4.6.4.2 
Evaluation measures for larger openings 
 
N/A 
4.6.4.3 
Use of metallized parts 
 
N/A 
4.6.5 
Adhesives for constructional purposes 
No barrier secured by 
adhesive inside enclosure. 
N/A 
 
Conditioning temperature (
C), time (weeks) ........ : 
 
 
 
4.7 
Resistance to fire 
P 
4.7.1 
Reducing the risk of ignition and spread of flame 
Method 1: Selection and 
application of components 
and materials that minimize 
the possibility of ignition and 
spread of flame 
 
Method 1, selection and application of components 
wiring and materials 
Selection and application of 
components, wiring and 
materials, which reduce the 
possibility of ignition and 
spread of flame by the use of 
fire enclosure (see appended 
critical component table) 
 
Method 2, application of all of simulated fault 
condition tests 
 
N/A 
4.7.2 
Conditions for a fire enclosure 
 
4.7.2.1 
Parts requiring a fire enclosure 
A fire enclosure covers all 
parts 
4.7.2.2 
Parts not requiring a fire enclosure 
 
N/A 
4.7.3 
Materials 
 
Page 24 of 88                        Report No. EFSN13070129E-1 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1C 
 
 
4.7.3.1 
General 
Components and materials 
have adequate flammability 
classification.  
See appended table 1.5.1 
4.7.3.2 
Materials for fire enclosures 
V-0 plastic enclosure used 
4.7.3.3 
Materials for components and other parts outside 
fire enclosures 
 
N/A 
4.7.3.4 
Materials for components and other parts inside 
fire enclosures 
PCB are rated V-0. Other 
materials inside fire enclosure 
are minimum V-1 material or 
better 
4.7.3.5 
Materials for air filter assemblies 
No air filters in the equipment 
N/A 
4.7.3.6 
Materials used in high-voltage components 
No parts exceeding 4kV 
N/A 
 
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS 
5.1 
Touch current and protective conductor current 
Evaluated in approved adapter 
N/A 
5.1.1 
General 
 
N/A 
5.1.2 
Configuration of equipment under test (EUT) 
 
N/A 
5.1.2.1 
Single connection to an a.c. mains supply 
 
N/A 
5.1.2.2 
Redundant multiple connections to an a.c. mains 
supply 
 
N/A 
5.1.2.3 
Simultaneous multiple connections to an a.c. 
mains supply 
 
N/A 
5.1.3 
Test circuit 
 
N/A 
5.1.4 
Application of measuring instrument 
 
N/A 
5.1.5 
Test procedure 
 
N/A 
5.1.6 
Test measurements 
 
N/A 
 
Supply voltage (V)  ................................................ :   
 
 
Measured touch current (mA)  .............................. :   
 
 
Max. allowed touch current (mA)  ......................... :   
 
 
Measured protective conductor current (mA)  ...... :   
 
 
Max. allowed protective conductor current (mA) .. :   
 
5.1.7 
Equipment with touch current exceeding 3,5 mA 
 
N/A 
5.1.7.1 
General  ................................................................ :   
N/A 
5.1.7.2 
Simultaneous multiple connections to the supply 
 
N/A 
5.1.8 
Touch currents to telecommunication networks and 
cable distribution systems and from 
telecommunication networks 
Not connected to a 
telecommunication network or 
cable distribution systems 
N/A 
 
Page 25 of 88                        Report No. EFSN13070129E-1 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1C 
 
 
5.1.8.1 
Limitation of the touch current to a 
telecommunication network or to a cable 
distribution system 
 
N/A 
 
Supply voltage (V)  ................................................ :   
 
 
Measured touch current (mA)  .............................. :   
 
 
Max. allowed touch current (mA)  ......................... :   
 
5.1.8.2 
Summation of touch currents from 
telecommunication networks 
 
N/A 
 
a) EUT with earthed telecommunication ports  ..... :   
N/A 
 
b) EUT whose telecommunication ports have no 
reference to protective earth 
 
N/A 
 
5.2 
Electric strength 
Evaluated in approved apdater 
N/A 
5.2.1 
General 
 
N/A 
5.2.2 
Test procedure  
 
N/A 
 
5.3 
Abnormal operating and fault conditions 
5.3.1 
Protection against overload and abnormal 
operation 
(see appended table 5.3) 
5.3.2 
Motors 
 
N/A 
5.3.3 
Transformers 
 
N/A 
5.3.4 
Functional insulation ............................................. :  Functional insulation complies 
with the requirements (c) 
5.3.5 
Electromechanical components 
The equipment does not have 
any electromechanical 
components  
N/A 
5.3.6 
Audio amplifiers in ITE  ......................................... :   
5.3.7 
Simulation of faults 
(see appended table 5.3) 
5.3.8 
Unattended equipment 
 
N/A 
5.3.9 
Compliance criteria for abnormal operating and 
fault conditions 
See below 
5.3.9.1 
During the tests 
No fire, emission of molten 
metal or deformation of 
enclosure was noted during 
the tests 
5.3.9.2 
After the tests 
Neither fire occurred nor 
molten metal emitted. No 
need to do electric strength 
test. 
 
 
 
 
Page 26 of 88                        Report No. EFSN13070129E-1 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1C 
 
 
CONNECTION TO TELECOMMUNICATION NETWORKS 
N/A 
6.1 
Protection of telecommunication network service persons, and users of other 
equipment connected to the network, from hazards in the equipment 
N/A 
6.1.1 
Protection from hazardous voltages 
N/A 
6.1.2 
Separation of the telecommunication network from earth 
N/A 
6.1.2.1 
Requirements 
(see appended table 5.2)  
N/A 
 
Supply voltage (V)  ................................................ : 
 
 
 
Current  in the test circuit  (mA)  ........................... : 
 
 
6.1.2.2 
Exclusions  ............................................................ : 
 
N/A 
 
6.2 
Protection of equipment users from overvoltages on telecommunication 
networks 
N/A 
6.2.1 
Separation requirements 
 
N/A 
6.2.2 
Electric strength test procedure 
 
N/A 
6.2.2.1 
Impulse test 
(see appended table 5.2)  
N/A 
6.2.2.2 
Steady-state test 
(see appended table 5.2)  
N/A 
6.2.2.3 
Compliance criteria 
 
N/A 
 
6.3 
Protection of the telecommunication wiring system from overheating 
N/A 
 
Max. output current (A)  ........................................ : 
 
 
 
Current limiting method  ........................................ : 
 
 
 
CONNECTION TO CABLE DISTRIBUTION SYSTEMS 
N/A 
7.1 
General 
Not connected to Cable 
Distribution System. 
N/A 
7.2 
Protection of cable distribution system service 
persons, and users of other equipment connected 
to the system, from hazardous voltages in the 
equipment 
 
N/A 
7.3 
Protection of equipment users from overvoltages 
on the cable distribution system 
 
N/A 
7.4 
Insulation between primary circuits and cable 
distribution systems 
 
N/A 
7.4.1 
General 
 
N/A 
7.4.2 
Voltage surge test 
(see appended table 5.2) 
N/A 
7.4.3 
Impulse test 
(see appended table 5.2) 
N/A 
 
 