JBL FLIP II (serv.man6) EMC - CB Certificate ▷ View online
Page 23 of 88 Report No. EFSN13070129E-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1C
4.5.3
Temperature limits for materials
(see appended table 4.5)
P
4.5.4
Touch temperature limits
(see appended table 4.5)
P
4.5.5
Resistance to abnormal heat ............................... :
N/A
4.6
Openings in enclosures
P
4.6.1
Top and side openings
No any opening
P
Dimensions (mm) ................................................. :
4.6.2
Bottoms of fire enclosures
No any opening
P
Construction of the bottomm, dimensions (mm) .. :
4.6.3
Doors or covers in fire enclosures
No doors or covers.
N/A
4.6.4
Openings in transportable equipment
Not transportable equipment.
N/A
4.6.4.1
Constructional design measures
N/A
Dimensions (mm) ................................................. :
4.6.4.2
Evaluation measures for larger openings
N/A
4.6.4.3
Use of metallized parts
N/A
4.6.5
Adhesives for constructional purposes
No barrier secured by
adhesive inside enclosure.
adhesive inside enclosure.
N/A
Conditioning temperature (
C), time (weeks) ........ :
4.7
Resistance to fire
P
4.7.1
Reducing the risk of ignition and spread of flame
Method 1: Selection and
application of components
and materials that minimize
the possibility of ignition and
spread of flame
application of components
and materials that minimize
the possibility of ignition and
spread of flame
P
Method 1, selection and application of components
wiring and materials
wiring and materials
Selection and application of
components, wiring and
materials, which reduce the
possibility of ignition and
spread of flame by the use of
fire enclosure (see appended
critical component table)
components, wiring and
materials, which reduce the
possibility of ignition and
spread of flame by the use of
fire enclosure (see appended
critical component table)
P
Method 2, application of all of simulated fault
condition tests
condition tests
N/A
4.7.2
Conditions for a fire enclosure
P
4.7.2.1
Parts requiring a fire enclosure
A fire enclosure covers all
parts
parts
P
4.7.2.2
Parts not requiring a fire enclosure
N/A
4.7.3
Materials
P
Page 24 of 88 Report No. EFSN13070129E-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1C
4.7.3.1
General
Components and materials
have adequate flammability
classification.
See appended table 1.5.1
have adequate flammability
classification.
See appended table 1.5.1
P
4.7.3.2
Materials for fire enclosures
V-0 plastic enclosure used
P
4.7.3.3
Materials for components and other parts outside
fire enclosures
fire enclosures
N/A
4.7.3.4
Materials for components and other parts inside
fire enclosures
fire enclosures
PCB are rated V-0. Other
materials inside fire enclosure
are minimum V-1 material or
better
materials inside fire enclosure
are minimum V-1 material or
better
P
4.7.3.5
Materials for air filter assemblies
No air filters in the equipment
N/A
4.7.3.6
Materials used in high-voltage components
No parts exceeding 4kV
N/A
5
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS
P
5.1
Touch current and protective conductor current
Evaluated in approved adapter
N/A
5.1.1
General
N/A
5.1.2
Configuration of equipment under test (EUT)
N/A
5.1.2.1
Single connection to an a.c. mains supply
N/A
5.1.2.2
Redundant multiple connections to an a.c. mains
supply
supply
N/A
5.1.2.3
Simultaneous multiple connections to an a.c.
mains supply
mains supply
N/A
5.1.3
Test circuit
N/A
5.1.4
Application of measuring instrument
N/A
5.1.5
Test procedure
N/A
5.1.6
Test measurements
N/A
Supply voltage (V) ................................................ :
Measured touch current (mA) .............................. :
Max. allowed touch current (mA) ......................... :
Measured protective conductor current (mA) ...... :
Max. allowed protective conductor current (mA) .. :
5.1.7
Equipment with touch current exceeding 3,5 mA
N/A
5.1.7.1
General ................................................................ :
N/A
5.1.7.2
Simultaneous multiple connections to the supply
N/A
5.1.8
Touch currents to telecommunication networks and
cable distribution systems and from
telecommunication networks
cable distribution systems and from
telecommunication networks
Not connected to a
telecommunication network or
cable distribution systems
telecommunication network or
cable distribution systems
N/A
Page 25 of 88 Report No. EFSN13070129E-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1C
5.1.8.1
Limitation of the touch current to a
telecommunication network or to a cable
distribution system
telecommunication network or to a cable
distribution system
N/A
Supply voltage (V) ................................................ :
Measured touch current (mA) .............................. :
Max. allowed touch current (mA) ......................... :
5.1.8.2
Summation of touch currents from
telecommunication networks
telecommunication networks
N/A
a) EUT with earthed telecommunication ports ..... :
N/A
b) EUT whose telecommunication ports have no
reference to protective earth
reference to protective earth
N/A
5.2
Electric strength
Evaluated in approved apdater
N/A
5.2.1
General
N/A
5.2.2
Test procedure
N/A
5.3
Abnormal operating and fault conditions
P
5.3.1
Protection against overload and abnormal
operation
operation
(see appended table 5.3)
P
5.3.2
Motors
N/A
5.3.3
Transformers
N/A
5.3.4
Functional insulation ............................................. : Functional insulation complies
with the requirements (c)
P
5.3.5
Electromechanical components
The equipment does not have
any electromechanical
components
any electromechanical
components
N/A
5.3.6
Audio amplifiers in ITE ......................................... :
P
5.3.7
Simulation of faults
(see appended table 5.3)
P
5.3.8
Unattended equipment
N/A
5.3.9
Compliance criteria for abnormal operating and
fault conditions
fault conditions
See below
P
5.3.9.1
During the tests
No fire, emission of molten
metal or deformation of
enclosure was noted during
the tests
metal or deformation of
enclosure was noted during
the tests
P
5.3.9.2
After the tests
Neither fire occurred nor
molten metal emitted. No
need to do electric strength
test.
molten metal emitted. No
need to do electric strength
test.
P
Page 26 of 88 Report No. EFSN13070129E-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1C
6
CONNECTION TO TELECOMMUNICATION NETWORKS
N/A
6.1
Protection of telecommunication network service persons, and users of other
equipment connected to the network, from hazards in the equipment
equipment connected to the network, from hazards in the equipment
N/A
6.1.1
Protection from hazardous voltages
N/A
6.1.2
Separation of the telecommunication network from earth
N/A
6.1.2.1
Requirements
(see appended table 5.2)
N/A
Supply voltage (V) ................................................ :
Current in the test circuit (mA) ........................... :
6.1.2.2
Exclusions ............................................................ :
N/A
6.2
Protection of equipment users from overvoltages on telecommunication
networks
networks
N/A
6.2.1
Separation requirements
N/A
6.2.2
Electric strength test procedure
N/A
6.2.2.1
Impulse test
(see appended table 5.2)
N/A
6.2.2.2
Steady-state test
(see appended table 5.2)
N/A
6.2.2.3
Compliance criteria
N/A
6.3
Protection of the telecommunication wiring system from overheating
N/A
Max. output current (A) ........................................ :
Current limiting method ........................................ :
7
CONNECTION TO CABLE DISTRIBUTION SYSTEMS
N/A
7.1
General
Not connected to Cable
Distribution System.
Distribution System.
N/A
7.2
Protection of cable distribution system service
persons, and users of other equipment connected
to the system, from hazardous voltages in the
equipment
persons, and users of other equipment connected
to the system, from hazardous voltages in the
equipment
N/A
7.3
Protection of equipment users from overvoltages
on the cable distribution system
on the cable distribution system
N/A
7.4
Insulation between primary circuits and cable
distribution systems
distribution systems
N/A
7.4.1
General
N/A
7.4.2
Voltage surge test
(see appended table 5.2)
N/A
7.4.3
Impulse test
(see appended table 5.2)
N/A
Click on the first or last page to see other FLIP II (serv.man6) service manuals if exist.