DOWNLOAD LG LP-K3060HL_HA / LP-K3060ZL_ZA Service Manual ↓ Size: 990.05 KB | Pages: 44 in PDF or view online for FREE

Model
LP-K3060HL_HA LP-K3060ZL_ZA
Pages
44
Size
990.05 KB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
lp-k3060hl-ha-lp-k3060zl-za.zip
Date

LG LP-K3060HL_HA / LP-K3060ZL_ZA Service Manual ▷ View online

–3–
Indoor Unit
Power Switch ON/OFF
Operation Mode Control
Indoor Fan Speed Control
Jet Cool
Energy Saving
Room Temperature control
Sensing Heat Exchanger Temperature
Soft Dry Operation Mode
Time Delay Safety Control
Fan Operation
AutoRestart
• Cooling, Heating, Soft Dry, Fan
• High, Low
• Speed Cooling operates super high fan speed in cooling mode
• Cooling Mode only
• Maintains the room temperature in accordance with the Setting Temp. 
• Up: up to 30°C
• Down: down to 16°C
• Heat exchanger temperature sensor (Thermistor)
• Intermittent operation of fan at low speed.
• Restarting is inhibited for approx. 3 minutes.
• Used to circulate room air without cooling.
• The power comes on again after a power failure.
Functions
–4–
• Intermittent operation of fan at low speed.
• Used to circulate room air without cooling.
• OFF Timer (1, 2, 3,......7 hour)
• Speed cooling operates super high fan speed in cooling mode.
• Airflow direction Auto-swing and Manual Contol.
• Up: up to 30°C
• Down: down to 16°C
• High, Low
• High, Low
Remote Control
Operation ON/OFF
Cooling Operation Mode
Heating Operation Mode
Sot Dry Operation Mode
Fan Operation
Timer Control
Jet Cool
Energy Saving
Airflow Direction Control
Room Temperature Control
Indoor Fan speed control
–5–
Outdoor Unit
Deice Control
Outdoor Fan Speed Control
Sensing Heat Exchanger Temperature
Sensing Discharge Pressure For Compressor
• De-ice PCB
• One speed
• Heat exchanger temperature sensor (Thermistor)
• Discharge pressure sensor (High Pressure Switch)
1. Selection of the best location
1) Indoor unit 
• There should not be any heat source or steam
near the unit.
• There should not be any obstacles to prevent the
air circulation.
• A place where air circulation in the room will be
good.
• A place where drainage can be easily obtained.
• A place where noise prevention is taken into con-
sideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the
wall, ceiling, fence, or other obstacles.
2) Outdoor unit
• If an awning is built over the unit to prevent direct
sunlight or rain exposure, be careful that heat
radiation from the condenser is not restricted.
• There should not be any animals or plants which
could be affected by discharged hot air.
• Ensure the space indicated by arrows from the
wall, ceiling, fence, or other obstacles.
–15–
Installation of Indoor, Outdoor Unit
50cm
50cm
50cm
100cm
5cm
5cm
40cm
100cm
A
B
Indoor unit
Outdoor unit
3) Piping length and the elevation
Cooling Only Model
5/8"
3/8"
30
20
-
PIPE SIZE
MODEL
GAS SIDE LIQUID SIDE
Max. 
Length
A (m)
Max.
Elevation
B (m)
Page of 44
Display

LG LP-K3060HL_HA / LP-K3060ZL_ZA Service Manual ▷ Download

  • DOWNLOAD LG LP-K3060HL_HA / LP-K3060ZL_ZA Service Manual ↓ Size: 990.05 KB | Pages: 44 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the LG LP-K3060HL_HA / LP-K3060ZL_ZA in PDF for free, which will help you to disassemble, recover, fix and repair LG LP-K3060HL_HA / LP-K3060ZL_ZA Air Conditioner. Information contained in LG LP-K3060HL_HA / LP-K3060ZL_ZA Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.