JBL FLIP II (serv.man6) EMC - CB Certificate ▷ View online
Page 31 of 88 Report No. EFSN13070129E-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1C
M.3.2.2
Tripping device
N/A
M.3.2.3
Monitoring voltage (V) .......................................... :
N/A
N
ANNEX N, IMPULSE TEST GENERATORS (see 1.5.7.2, 1.5.7.3, 2.10.3.9,
6.2.2.1, 7.3.2, 7.4.3 and Clause G.5)
6.2.2.1, 7.3.2, 7.4.3 and Clause G.5)
N/A
N.1
ITU-T impulse test generators
N/A
N.2
IEC 60065 impulse test generator
N/A
P
ANNEX P, NORMATIVE REFERENCES
Q
ANNEX Q, Voltage dependent resistors (VDRs) (see 1.5.9.1)
N/A
a) Preferred climatic categories ........................... :
N/A
b) Maximum continuous voltage .......................... :
N/A
c) Pulse current .................................................... :
N/A
R
ANNEX R, EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL
PROGRAMMES
PROGRAMMES
N/A
R.1
Minimum separation distances for unpopulated
coated printed boards (see 2.10.6.2)
coated printed boards (see 2.10.6.2)
N/A
R.2
Reduced clearances (see 2.10.3)
N/A
S
ANNEX S, PROCEDURE FOR IMPULSE TESTING (see 6.2.2.3)
N/A
S.1
Test equipment
N/A
S.2
Test procedure
N/A
S.3
Examples of waveforms during impulse testing
N/A
T
ANNEX T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER
(see 1.1.2)
(see 1.1.2)
N/A
U
ANNEX U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED
INSULATION (see 2.10.5.4)
INSULATION (see 2.10.5.4)
N/A
V
ANNEX V, AC POWER DISTRIBUTION SYSTEMS (see 1.6.1)
N/A
V.1
Introduction
N/A
V.2
TN power distribution systems
N/A
W
ANNEX W, SUMMATION OF TOUCH CURRENTS
N/A
Page 32 of 88 Report No. EFSN13070129E-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1C
W.1
Touch current from electronic circuits
N/A
W.1.1
Floating circuits
N/A
W.1.2
Earthed circuits
N/A
W.2
Interconnection of several equipments
N/A
W.2.1
Isolation
N/A
W.2.2
Common return, isolated from earth
N/A
W.2.3
Common return, connected to protective earth
N/A
X
ANNEX X, MAXIMUM HEATING EFFECT IN TRANSFORMER TESTS
(see clause C.1)
(see clause C.1)
N/A
X.1
Determination of maximum input current
N/A
X.2
Overload test procedure
N/A
Y
ANNEX Y, ULTRAVIOLET LIGHT CONDITIONING TEST (see 4.3.13.3)
N/A
Y.1
Test apparatus ...................................................... :
N/A
Y.2
Mounting of test samples ..................................... :
N/A
Y.3
Carbon-arc light-exposure apparatus ................... :
N/A
Y.4
Xenon-arc light exposure apparatus .................... :
N/A
Z
ANNEX Z, OVERVOLTAGE CATEGORIES (see 2.10.3.2 and Clause G.2)
P
AA
ANNEX AA, MANDREL TEST (see 2.10.5.8)
N/A
BB
ANNEX BB, CHANGES IN THE SECOND EDITION
CC
ANNEX CC, Evaluation of integrated circuit (IC) current limiters
N/A
CC.1
General
N/A
CC.2
Test program 1……………………………………….:
N/A
CC.3
Test program 2……………………………………….:
N/A
DD
ANNEX DD, Requirements for the mounting means of rack-mounted
equipment
equipment
N/A
DD.1
General
N/A
DD.2
Mechanical strength test, variable N………………..:
N/A
DD.3
Mechanical strength test, 250N, including end
stops……………………………………………………:
stops……………………………………………………:
N/A
DD.4
Compliance……………………………………………:
N/A
Page 33 of 88 Report No. EFSN13070129E-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1C
EE
ANNEX EE, Household and home/office document/media shredders
N/A
EE.1
General
N/A
EE.2
Markings and instructions
N/A
Use of markings or symbols…………………………:
N/A
Information of user instructions, maintenance
and/or servicing instructions…………………………:
and/or servicing instructions…………………………:
N/A
EE.3
Inadvertent reactivation test…………………………:
N/A
EE.4
Disconnection of power to hazardous moving parts:
N/A
Use of markings or symbols…………………………:
N/A
EE.5
Protection against hazardous moving parts
N/A
Test with
test finger (Figure 2A) ……………..……:
N/A
Test with wedge probe (Figure EE1 and EE2) ……:
N/A
Page 34 of 88 Report No. EFSN13070129E-1
TRF No. IEC60950_1C
1.5.1
TABLE: List of critical components
P
Object/part No.
Manufacturer/
trademark
Type/model
Technical data
Standard
(Edition / year)
Mark(s) of
conformity 1)
AC Adapter
Group Intellect
Power
Technology
Limited
Power
Technology
Limited
F5V-1C-1U
Input:
100-240VAC
50/60Hz;
300mA
Output: 5V DC,
1.0A
100-240VAC
50/60Hz;
300mA
Output: 5V DC,
1.0A
EN 60950-1
IEC 60950-1
IEC 60950-1
CB Certif. No.:
JPTUV-051867
CB report No.:
17032615 001
JPTUV-051867
CB report No.:
17032615 001
Enclosure
CHI MEI
CORPORATIO
N
CORPORATIO
N
PA-765(+)
V-0, 85°C
Min. thickness
1.5mm
Min. thickness
1.5mm
UL 94
UL 746
UL 746
UL E56070
PCB
GUANGDONG
CHENGDE
PRINTED
CIRCUIT CO
LTD
CHENGDE
PRINTED
CIRCUIT CO
LTD
D1
V-0, 130°C,
min. thickness
1.2mm
min. thickness
1.2mm
UL 746
UL 94
UL 94
UL E322995
(Alternative)
Various
Various
V-0, min.
130°C, min.
thickness
1.2mm
130°C, min.
thickness
1.2mm
UL 746
UL 94
UL 94
UL
Various
Various
Min. 28AWG,
30Vac, VW-1,
80
30Vac, VW-1,
80
C
UL 758
UL
Interconnecting
cables
cables
Various
Various
Min. 26AWG,
30Vac, VW-1,
80
30Vac, VW-1,
80
C
UL 758
UL
Battery Pack
Apower
Electronics Co.,
LTD
Electronics Co.,
LTD
AEC653055-2P 3.7V with PCM,
capacity:
2000mAh
Max. charge
current:
2000mA
Max. discharge
current:6000mA
2000mAh
Max. charge
current:
2000mA
Max. discharge
current:6000mA
IEC/EN 60950-1 Tested with
appliance
-Battery Cell
Apower
Electronics Co.,
LTD
Electronics Co.,
LTD
AEC653055
3.7Vdc,
1000mAh
1000mAh
UL1642
TUVPS Z2
120882069001
120882069001
-Connection
wires
wires
Various
Various
VW-1 or FT-1,
80°C, min.
24AWG.
80°C, min.
24AWG.
UL758
UL
-NTC Sensing
DONG GUAN
SENSICOM
ELECTRONICS
TECHNOLOGY
CO LTD
SENSICOM
ELECTRONICS
TECHNOLOGY
CO LTD
SNG103F
10K ohm,
300°C
Class C3
300°C
Class C3
UL1434
UL
-Protective IC
SEIKO
S8242AAK
-
-
-
Battery Pack
TCL
HYPERPOWER
BATTERIES
INC
HYPERPOWER
BATTERIES
INC
PR-652954
3.7V with PCM,
capacity:
2000mAh.
Max. charge
current:
2000mA.
Max. discharge
current:6000mA
capacity:
2000mAh.
Max. charge
current:
2000mA.
Max. discharge
current:6000mA
IEC/EN 60950-1 Tested with