JBL FLIP II (serv.man6) EMC - CB Certificate ▷ View online
Page 19 of 88 Report No. EFSN13070129E-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1C
3.2.5.1
AC power supply cords
N/A
Type ...................................................................... :
—
Rated current (A), cross-sectional area (mm
2
),
AWG ...................................................................... :
—
3.2.5.2
DC power supply cords
N/A
3.2.6
Cord anchorages and strain relief
N/A
Mass of equipment (kg), pull (N) .......................... :
—
Longitudinal displacement (mm) ........................... :
—
3.2.7
Protection against mechanical damage
N/A
3.2.8
Cord guards
N/A
Diameter or minor dimension D (mm); test mass (g)
............................................................................... :
............................................................................... :
—
Radius of curvature of cord (mm) .......................... :
—
3.2.9
Supply wiring space
N/A
3.3
Wiring terminals for connection of external conductors
N/A
3.3.1
Wiring terminals
N/A
3.3.2
Connection of non-detachable power supply cords
N/A
3.3.3
Screw terminals
N/A
3.3.4
Conductor sizes to be connected
N/A
Rated current (A), cord/cable type, cross-sectional
area (mm
area (mm
2
) ............................................................. :
3.3.5
Wiring terminal sizes
N/A
Rated current (A), type, nominal thread diameter
(mm) ...................................................................... :
(mm) ...................................................................... :
3.3.6
Wiring terminal design
N/A
3.3.7
Grouping of wiring terminals
N/A
3.3.8
Stranded wire
N/A
3.4
Disconnection from the mains supply
The unit supplied by DC 5V; also evluated in approved adaper
N/A
3.4.1
General requirement
N/A
3.4.2
Disconnect devices
N/A
3.4.3
Permanently connected equipment
N/A
3.4.4
Parts which remain energized
N/A
3.4.5
Switches in flexible cords
N/A
3.4.6
Number of poles - single-phase and d.c. equipment
N/A
3.4.7
Number of poles - three-phase equipment
N/A
Page 20 of 88 Report No. EFSN13070129E-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1C
3.4.8
Switches as disconnect devices
N/A
3.4.9
Plugs as disconnect devices
N/A
3.4.10
Interconnected equipment
N/A
3.4.11
Multiple power sources
N/A
3.5
Interconnection of equipment
P
3.5.1
General requirements
Considered.
P
3.5.2
Types of interconnection circuits ........................... : Interconnection circuits are
SELV and LPS circuits
P
3.5.3
ELV circuits as interconnection circuits
No ELV interconnection
circuits
circuits
N/A
3.5.4
Data ports for additional equipment
No data ports.
N/A
4
PHYSICAL REQUIREMENTS
P
4.1
Stability
N/A
Angle of 10
N/A
Test force (N) ........................................................ :
N/A
4.2
Mechanical strength
Class III device, no hazardous voltage/energy inside
N/A
4.2.1
General
N/A
Rack-mounted equipment.
N/A
4.2.2
Steady force test, 10 N
N/A
4.2.3
Steady force test, 30 N
N/A
4.2.4
Steady force test, 250 N
N/A
4.2.5
Impact test
N/A
Fall test
N/A
Swing test
N/A
4.2.6
Drop test; height (mm) .......................................... :
N/A
4.2.7
Stress relief test
N/A
4.2.8
Cathode ray tubes
N/A
Picture tube separately certified ............................ :
N/A
4.2.9
High pressure lamps
N/A
4.2.10
Wall or ceiling mounted equipment; force (N) ....... :
N/A
4.3
Design and construction
P
4.3.1
Edges and corners
All edges and corners are
rounded and/or smoothed.
rounded and/or smoothed.
P
Page 21 of 88 Report No. EFSN13070129E-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1C
4.3.2
Handles and manual controls; force (N) ............. :
N/A
4.3.3
Adjustable controls
No hazardous adjustable
controls.
controls.
N/A
4.3.4
Securing of parts
Electrical and mechanical
connections can be expected
to withstand usual mechanical
stress.
connections can be expected
to withstand usual mechanical
stress.
P
4.3.5
Connection by plugs and sockets
P
4.3.6
Direct plug-in equipment
Not intended to plug directly
into a wall socket-outlet.
into a wall socket-outlet.
N/A
Torque .................................................................. :
Compliance with the relevant mains plug standard
.............................................................................. :
.............................................................................. :
N/A
4.3.7
Heating elements in earthed equipment
No heating elements
provided.
provided.
N/A
4.3.8
Batteries
P
- Overcharging of a rechargeable battery
P
- Unintentional charging of a non-rechargeable
battery
battery
N/A
- Reverse charging of a rechargeable battery
According to the
configuration, battery can't be
reversed charging
configuration, battery can't be
reversed charging
N/A
- Excessive discharging rate for any battery
P
4.3.9
Oil and grease
Insulation in intended use not
considered to be exposed to
oil or grease.
considered to be exposed to
oil or grease.
N/A
4.3.10
Dust, powders, liquids and gases
The equipment does not
produce dust or use powders,
liquids and gases in the
equipment.
produce dust or use powders,
liquids and gases in the
equipment.
N/A
4.3.11
Containers for liquids or gases
No container for liquids or
gases used
gases used
N/A
4.3.12
Flammable liquids ................................................ :
The equipment does not
contain flammable liquid
contain flammable liquid
N/A
Quantity of liquid (l) .............................................. :
N/A
Flash point (
C) .................................................... :
N/A
4.3.13
Radiation
Refer below:
P
4.3.13.1
General
Refer below:
P
4.3.13.2
Ionizing radiation
The equipment does not
generate ionizing radiation.
generate ionizing radiation.
N/A
Measured radiation (pA/kg) .................................. :
Measured high-voltage (kV) ................................. :
Measured focus voltage (kV) ............................... :
Page 22 of 88 Report No. EFSN13070129E-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1C
CRT markings ...................................................... :
4.3.13.3
Effect of ultraviolet (UV) radiation on materials
The equipment does not
produce significant UV
radiation.
produce significant UV
radiation.
N/A
Part, property, retention after test, flammability
classification ......................................................... :
classification ......................................................... :
N/A
4.3.13.4
Human exposure to ultraviolet (UV) radiation ...... :
The equipment does not
produce significant UV
radiation.
produce significant UV
radiation.
N/A
4.3.13.5
Lasers (including laser diodes) and LEDs
P
4.3.13.5.1
Lasers (including laser diodes)
N/A
Laser class ........................................................... :
4.3.13.5.2
Light emitting diodes (LEDs)
LED indicating lights
P
4.3.13.6
Other types ........................................................... :
The equipment does not
generate other types of
radiation.
generate other types of
radiation.
N/A
4.4
Protection against hazardous moving parts
N/A
4.4.1
General
No hazardous moving parts
within the equipment
within the equipment
N/A
4.4.2
Protection in operator access areas .................... :
N/A
Household and home/office document/media
shredders
shredders
N/A
4.4.3
Protection in restricted access locations .............. :
N/A
4.4.4
Protection in service access areas
N/A
4.4.5
Protection against moving fan blades
N/A
4.4.5.1
General
N/A
Not considered
to cause pain or injury. a)……….:
N/A
Is considered to
cause pain, not injury. b) ………:
N/A
Considered to cause injury.
c) ………:
N/A
4.4.5.2
Protection for users
N/A
Use
of symbol or warning …………………………:
N/A
4.4.5.3
Protection for service persons
N/A
Use
of symbol or warning …………………………:
N/A
4.5
Thermal requirements
P
4.5.1
General
See appended table 4.5.1
P
4.5.2
Temperature tests
(see appended table 4.5)
P
Normal load condition per Annex L ...................... :
Click on the first or last page to see other FLIP II (serv.man6) service manuals if exist.