Page 11 of 88                        Report No. EFSN13070129E-1 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1C 
 
 
PROTECTION FROM HAZARDS 
2.1 
Protection from electric shock and energy hazards 
2.1.1 
Protection in operator access areas  
Supplied by approved adapter 
which provides SELV output 
only, and  no hazards live part 
in operator access areas. 
2.1.1.1 
Access to energized parts 
 
N/A 
 
Test by inspection  ................................................. :   
N/A 
 
Test with test finger (Figure 2A)  ............................ :   
N/A 
 
Test with test pin (Figure 2B)  ................................ :   
N/A 
 
Test with test probe (Figure 2C)  ........................... :  No TNV circuits within the 
equipment. 
N/A 
2.1.1.2 
Battery compartments  
TNV circuits within the 
equipment 
N/A 
2.1.1.3 
Access to ELV wiring 
No internal wiring at ELV 
accessible to the operator. 
N/A 
 
Working voltage (Vpeak or Vrms); minimum 
distance through insulation (mm) 
 
 
2.1.1.4 
Access to hazardous voltage circuit wiring 
No internal wiring at ELV 
accessible to the operator. 
N/A 
2.1.1.5 
Energy hazards  ..................................................... :   
N/A 
2.1.1.6 
Manual controls 
No conductive shafts of 
operating knobs, handles, 
levers and the like 
N/A 
2.1.1.7 
Discharge of capacitors in equipment 
 
N/A 
 
Measured voltage (V); time-constant (s) ................ :   
 
2.1.1.8 
Energy hazards 
– d.c. mains supply 
Not connected to DC mains 
supply. 
N/A 
 
a) Capacitor connected to the d.c. mains supply  .. :   
N/A 
 
 
N/A 
2.1.1.9 
Audio amplifiers  ..................................................... :   
2.1.2 
Protection in service access areas 
No bare parts operating at 
hazardous voltage in a 
service access area 
N/A 
2.1.3 
Protection in restricted access locations 
The equipment is not limited 
to be used in restricted 
access locations. 
N/A 
 
2.2 
SELV circuits 
2.2.1 
General requirements 
 
2.2.2 
Voltages under normal conditions (V)  ................... :  Between any conductor of the 
SELV circuits, 42.4Vpeak or 
60Vd.c. is not exceeded. 
 
Page 12 of 88                        Report No. EFSN13070129E-1 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1C 
 
 
2.2.3 
Voltages under fault conditions (V)  ....................... :  Under fault conditions 
voltages never exceed 71Vpk 
and 120Vdc and do not 
exceed 42.4Vpk or 60Vdc for 
more than 0.2 second 
2.2.4 
Connection of SELV circuits to other circuits  ...... : 
SELV circuits are only 
connected to other secondary 
circuits. SELV circuit and all 
interconnected circuits 
separated from primary by 
double/reinforced insulation 
 
2.3 
TNV circuits 
N/A 
2.3.1 
Limits 
No TNV circuits within the 
equipment. 
N/A 
 
Type of TNV circuits ............................................... :   
 
2.3.2 
Separation from other circuits and from accessible 
parts 
 
N/A 
2.3.2.1 
General requirements 
 
N/A 
2.3.2.2 
Protection by basic insulation 
 
N/A 
2.3.2.3 
Protection by earthing 
 
N/A 
2.3.2.4 
Protection by other constructions  ......................... :   
N/A 
2.3.3 
Separation from hazardous voltages 
 
N/A 
 
Insulation employed ............................................... :   
 
2.3.4 
Connection of TNV circuits to other circuits 
 
N/A 
 
Insulation employed ............................................... :   
 
2.3.5 
Test for operating voltages generated externally 
 
N/A 
 
 
 
 
2.4 
Limited current circuits 
N/A 
2.4.1 
General requirements 
 
N/A 
2.4.2 
Limit values 
 
N/A 
 
Frequency (Hz) ...................................................... :   
 
 
Measured current (mA) .......................................... :   
 
 
Measured voltage (V) ............................................. :   
 
 
Measured circuit capacitance (nF or µF) ............... :   
 
2.4.3 
Connection of limited current circuits to other 
circuits 
 
N/A 
 
2.5 
Limited power sources 
Evaluated in approved adapter 
N/A 
 
Page 13 of 88                        Report No. EFSN13070129E-1 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1C 
 
 
 
a) Inherently limited output 
 
N/A 
 
b) Impedance limited output 
 
N/A 
 
c) Regulating network limited output under normal 
operating and single fault condition 
 
N/A 
 
d) Overcurrent protective device limited output 
 
N/A 
 
Max. output voltage (V), max. output current (A), 
max. apparent power (VA) ..................................... : 
 
 
 
Current rating of overcurrent protective device (A) .:   
 
 
Use of integrated circuit (IC) current limiters 
 
 
 
2.6 
Provisions for earthing and bonding 
N/A 
2.6.1 
Protective earthing 
 
N/A 
2.6.2 
Functional earthing 
 
N/A 
2.6.3 
Protective earthing and protective bonding 
conductors 
 
N/A 
2.6.3.1 
General 
 
N/A 
2.6.3.2 
Size of protective earthing conductors 
 
N/A 
 
Rated current (A), cross-sectional area (mm
2
), 
AWG ....................................................................... : 
 
 
2.6.3.3 
Size of protective bonding conductors 
 
N/A 
 
Rated current (A), cross-sectional area (mm
2
), 
AWG ....................................................................... : 
 
 
 
Protective current rating (A), cross-sectional area 
(mm
2
), AWG ........................................................... : 
 
 
2.6.3.4 
Resistance of earthing conductors and their 
terminations; resistance (
), voltage drop (V), test 
current (A), duration (min) ...................................... : 
 
N/A
 
2.6.3.5 
Colour of insulation ................................................ :   
N/A
 
2.6.4 
Terminals 
 
N/A
 
2.6.4.1 
General 
 
N/A
 
2.6.4.2 
Protective earthing and bonding terminals 
 
N/A
 
 
Rated current (A), type, nominal thread diameter 
(mm) ....................................................................... : 
 
 
2.6.4.3 
Separation of the protective earthing conductor 
from protective bonding conductors 
 
N/A 
2.6.5 
Integrity of protective earthing 
 
N/A 
2.6.5.1 
Interconnection of equipment 
 
N/A 
2.6.5.2 
Components in protective earthing conductors and 
protective bonding conductors 
 
N/A 
2.6.5.3 
Disconnection of protective earth 
 
N/A 
 
Page 14 of 88                        Report No. EFSN13070129E-1 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1C 
 
 
2.6.5.4 
Parts that can be removed by an operator 
 
N/A 
2.6.5.5 
Parts removed during servicing 
 
N/A 
2.6.5.6 
Corrosion resistance 
 
N/A 
2.6.5.7 
Screws for protective bonding 
 
N/A 
2.6.5.8 
Reliance on telecommunication network or cable 
distribution system 
 
N/A 
 
2.7 
Overcurrent and earth fault protection in primary circuits 
N/A 
2.7.1 
Basic requirements 
 
N/A 
 
Instructions when protection relies on building 
installation 
 
N/A 
2.7.2 
Faults not simulated in 5.3.7 
 
— 
2.7.3 
Short-circuit backup protection 
 
N/A 
2.7.4 
Number and location of protective devices  ........... :   
N/A 
2.7.5 
Protection by several devices 
 
N/A 
2.7.6 
Warning to service personnel ................................ :   
N/A 
 
2.8 
Safety interlocks 
N/A 
2.8.1 
General principles 
No safety interlocks or similar 
devices within the equipment 
N/A 
2.8.2 
Protection requirements 
 
N/A 
2.8.3 
Inadvertent reactivation 
 
N/A 
2.8.4 
Fail-safe operation 
 
N/A 
 
Protection against extreme hazard 
 
N/A 
2.8.5 
Moving parts 
 
N/A 
2.8.6 
Overriding  
 
N/A 
2.8.7 
Switches, relays and their related circuits 
 
N/A 
2.8.7.1 
Separation distances for contact gaps and their 
related circuits (mm)  ............................................. : 
 
N/A 
2.8.7.2 
Overload test 
 
N/A 
2.8.7.3 
Endurance test 
 
N/A 
2.8.7.4 
Electric strength test  
 
N/A 
2.8.8 
Mechanical actuators 
 
N/A 
 
2.9 
Electrical insulation 
Page of 90