DOWNLOAD JBL FLIP II (serv.man6) Service Manual ↓ Size: 3.8 MB | Pages: 90 in PDF or view online for FREE

Model
FLIP II (serv.man6)
Pages
90
Size
3.8 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
flip-ii-sm6.pdf
Date

JBL FLIP II (serv.man6) EMC - CB Certificate ▷ View online

 
Page 7 of 88                           Report No. EFSN13070129E-1 
 
TRF No. IEC60950_1C 
 
 
General remarks: 
The test results presented in this report relate only to the object tested. 
This report shall not be reproduced, except in full, without the written approval of the Issuing testing 
laboratory. 
"(see Enclosure #)" refers to additional information appended to the report. 
"(see appended table)" refers to a table appended to the report. 
 
 
The related applicable CTL, OSM decisions have been considered and the requirements found 
fulfilled
 
 
Throughout this report a 
 comma / 
 point is used as the decimal separator. 
Manufacturer’s Declaration per sub-clause 6.2.5 of IECEE 02: 
The application for obtaining a CB Test Certificate 
includes more than one factory location and a 
declaration from the Manufacturer stating that the 
sample(s) submitted for evaluation is (are) 
representative of the products from each factory has 
been provided ............................................................... : 
 Yes 
 Not applicable 
 
When differences exist; they shall be identified in the General product information section. 
Name and address of factory (ies) .......................... :  Factory 1:  
Guoguang Electric Co., Ltd 
No. 8 Jinghu Road, Xinhua Street, Huadu Reg, 
Guangzhou, 510800, P. R. China 
 
Factory 2: 
TCL TECHNOLY ELECTRONICS (HUIZHOU) CO., 
LTD 
Section 37, Zhongkai High-tech Development Zone, 
Huizhou City, Guang Dong Province, China, 516006. 
General product information: 
 
The unit covered by this report is Portable Wireless speaker with Bluetooth, used with information 
technology equipment 
The unit with two speaker, each speaker is 8ohm, 6W  
The unit is Class III equipment, rated 5Vdc, 1.0A, supplied by approved external power supply, Electronic 
components mounted on PWB, housed with plastic enclosure 
 
Adapter rating: Input 100-240VAC, 50/60Hz, 0.3A; Output 5V DC, 1.0A 
 
Abbreviations used in the report: 
 
- normal conditions   
 
N.C.   
 
 
- single fault conditions 
 
S.F.C 
- functional insulation 
 
OP 
 
 
 
- basic insulation 
 
 
BI 
- double insulation   
 
DI 
 
 
 
- supplementary insulation SI 
- between parts of opposite 
- polarity 
 
 
 
BOP   
 
 
- reinforced insulation 
 
RI 
 
Indicate used abbreviations (if any) 
 
 
 
 
 
Page 8 of 88                        Report No. EFSN13070129E-1 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1C 
 
 
GENERAL 
 
1.5 
Components 
1.5.1 
General 
See below 
 
Comply with IEC 60950-1 or relevant component 
standard  
(see appended table 1.5.1). 
1.5.2 
Evaluation and testing of components 
Certified components are 
used in accordance with their 
ratings, certifications and they 
comply with applicable parts 
of this standard.  
Components not certified are 
used in accordance with their 
ratings and they comply with 
applicable parts of IEC 60950-
1 and the relevant component 
standard.  
Components, for which no 
relevant IEC-standard exists, 
have been tested under the 
conditions occurring in the 
equipment, using applicable 
parts of IEC 60950-1. 
1.5.3 
Thermal controls 
No thermal control. 
N/A 
1.5.4 
Transformers 
 
N/A 
1.5.5 
Interconnecting cables 
Interconnecting cables comply 
with the relevant requirements 
of this standard. 
1.5.6 
Capacitors bridging insulation 
Evaluated in approved 
adapter 
N/A 
1.5.7 
Resistors bridging insulation 
Evaluated in approved 
adapter 
N/A 
1.5.7.1 
Resistors bridging functional, basic or 
supplementary insulation 
 
N/A 
1.5.7.2 
Resistors bridging double or reinforced insulation 
between a.c. mains and other circuits 
 
N/A 
1.5.7.3 
Resistors bridging double or reinforced insulation 
between a.c. mains and antenna or coaxial cable  
 
N/A 
1.5.8 
Components in equipment for IT power systems 
 
N/A 
1.5.9 
Surge suppressors 
Evaluated in approved 
adapter 
N/A 
1.5.9.1 
General 
 
N/A 
1.5.9.2 
Protection of VDRs 
 
N/A 
1.5.9.3 
Bridging of functional insulation by a VDR 
 
N/A 
1.5.9.4 
Bridging of basic insulation by a VDR 
 
N/A 
 
Page 9 of 88                        Report No. EFSN13070129E-1 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1C 
 
 
1.5.9.5 
Bridging of supplementary, double or reinforced 
insulation by a VDR 
 
N/A 
 
1.6 
Power interface 
1.6.1 
AC power distribution systems 
Not directly connected to AC 
mains also evaluated in 
approved adapter 
N/A 
1.6.2 
Input current 
(see appended table 1.6.2)  
1.6.3 
Voltage limit of hand-held equipment 
This equipment is not 
handheld equipment 
N/A 
1.6.4 
Neutral conductor  
 
N/A 
 
1.7 
Marking and instructions 
1.7.1 
Power rating and identification markings 
The required marking is 
located on the outside surface 
of the equipment.
 
1.7.1.1 
Power rating marking 
See below 
 
Multiple mains supply connections.........................: 
 
N/A 
 
Rated voltage(s) or voltage range(s) (V)  .............. :  5Vdc 
 
Symbol for nature of supply, for d.c. only .............. :  The symbol is marked on the 
label 
 
Rated frequency or rated frequency range (Hz)  ... :   
N/A 
 
Rated current (mA or A)  ........................................ :  1.0A 
1.7.1.2 
Identification markings 
See below 
 
Manufacturer’s name or trade-mark or 
identification mark  ................................................. : 
JBL
 
 
Model identification or type reference  ................... :  JBL FLIP 2
 
 
Symbol for Class II equipment only  ...................... :  Class III equipment 
N/A 
 
Other markings and symbols  ................................ :  Additional symbols or marking 
do not give rise to 
misunderstanding. 
1.7.2 
Safety instructions and marking 
English (Version in other 
language will be provided 
when submitted for national 
approval) 
1.7.2.1 
General 
 
1.7.2.2 
Disconnect devices 
Evaluated in approved 
adapter 
N/A 
1.7.2.3 
Overcurrent protective device 
 
N/A 
1.7.2.4 
IT power distribution systems 
 
N/A 
1.7.2.5 
Operator access with a tool 
 
N/A 
 
Page 10 of 88                        Report No. EFSN13070129E-1 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1C 
 
 
1.7.2.6 
Ozone 
The equipment does not 
produce Ozone. 
N/A 
1.7.3 
Short duty cycles 
The equipment is designed for 
continuous operation. 
N/A 
1.7.4 
Supply voltage adjustment  ................................... :  No Voltage adjustment. 
N/A 
 
Methods and means of adjustment; reference to 
installation instructions  ......................................... : 
 
N/A 
1.7.5 
Power outlets on the equipment  .......................... :  No standard power outlet. 
N/A 
1.7.6 
Fuse identification (marking, special fusing 
characteristics, cross-reference)  .......................... : 
 
N/A 
1.7.7 
Wiring terminals 
 
N/A 
1.7.7.1 
Protective earthing and bonding terminals  .......... :   
N/A 
1.7.7.2 
Terminals for a.c. mains supply conductors 
 
N/A 
1.7.7.3 
Terminals for d.c. mains supply conductors 
 
N/A 
1.7.8 
Controls and indicators 
See below 
N/A 
1.7.8.1 
Identification, location and marking  ..................... :  No safety relevant indicators, 
switches and controls 
provided 
N/A 
1.7.8.2 
Colours   ................................................................ :   
N/A 
1.7.8.3 
Symbols according to IEC 60417......................... : 
 
N/A 
1.7.8.4 
Markings using figures   ....................................... : 
No figures used 
N/A 
1.7.9 
Isolation of multiple power sources  ..................... : 
 
N/A 
1.7.10 
Thermostats and other regulating devices  .......... : 
No thermostats or other 
regulating devices. 
N/A 
1.7.11 
Durability 
The marking plate was 
subjected to the permanence 
of marking test. The marking 
plate was rubbed with cloth 
soaked with water for 15s and 
then again for 15s with the 
cloth soaked with petroleum 
spirit. After this test there was 
no damage to the marking 
plate. The marking on the 
label did not fade. There was 
no curling of the marking 
plate. 
1.7.12 
Removable parts 
No removable parts provided 
N/A 
1.7.13 
Replaceable batteries  ......................................... : 
No replaceable batteries 
provided 
N/A 
 
Language(s)  ........................................................ : 
See above 
 
1.7.14 
Equipment for restricted access locations ........... : 
The equipment is not intended 
to be use in restricted access 
locations. 
N/A 
 
Page of 90
Display