Page 7 of 88 Report No. EFSN13070129E-1
TRF No. IEC60950_1C
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
The related applicable CTL, OSM decisions have been considered and the requirements found
fulfilled
Throughout this report a
fulfilled
Throughout this report a
comma /
point is used as the decimal separator.
Manufacturer’s Declaration per sub-clause 6.2.5 of IECEE 02:
The application for obtaining a CB Test Certificate
includes more than one factory location and a
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory has
been provided ............................................................... :
includes more than one factory location and a
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory has
been provided ............................................................... :
Yes
Not applicable
When differences exist; they shall be identified in the General product information section.
Name and address of factory (ies) .......................... : Factory 1:
Guoguang Electric Co., Ltd
No. 8 Jinghu Road, Xinhua Street, Huadu Reg,
Guangzhou, 510800, P. R. China
Guangzhou, 510800, P. R. China
Factory 2:
TCL TECHNOLY ELECTRONICS (HUIZHOU) CO.,
LTD
LTD
Section 37, Zhongkai High-tech Development Zone,
Huizhou City, Guang Dong Province, China, 516006.
Huizhou City, Guang Dong Province, China, 516006.
General product information:
The unit covered by this report is Portable Wireless speaker with Bluetooth, used with information
technology equipment
The unit with two speaker, each speaker is 8ohm, 6W
The unit is Class III equipment, rated 5Vdc, 1.0A, supplied by approved external power supply, Electronic
components mounted on PWB, housed with plastic enclosure
Adapter rating: Input 100-240VAC, 50/60Hz, 0.3A; Output 5V DC, 1.0A
Abbreviations used in the report:
- normal conditions
N.C.
- single fault conditions
S.F.C
- functional insulation
OP
- basic insulation
BI
- double insulation
DI
- supplementary insulation SI
- between parts of opposite
- polarity
- polarity
BOP
- reinforced insulation
RI
Indicate used abbreviations (if any)
Page 8 of 88 Report No. EFSN13070129E-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1C
1
GENERAL
P
1.5
Components
P
1.5.1
General
See below
P
Comply with IEC 60950-1 or relevant component
standard
standard
(see appended table 1.5.1).
P
1.5.2
Evaluation and testing of components
Certified components are
used in accordance with their
ratings, certifications and they
comply with applicable parts
of this standard.
used in accordance with their
ratings, certifications and they
comply with applicable parts
of this standard.
Components not certified are
used in accordance with their
ratings and they comply with
applicable parts of IEC 60950-
1 and the relevant component
standard.
used in accordance with their
ratings and they comply with
applicable parts of IEC 60950-
1 and the relevant component
standard.
Components, for which no
relevant IEC-standard exists,
have been tested under the
conditions occurring in the
equipment, using applicable
parts of IEC 60950-1.
relevant IEC-standard exists,
have been tested under the
conditions occurring in the
equipment, using applicable
parts of IEC 60950-1.
P
1.5.3
Thermal controls
No thermal control.
N/A
1.5.4
Transformers
N/A
1.5.5
Interconnecting cables
Interconnecting cables comply
with the relevant requirements
of this standard.
with the relevant requirements
of this standard.
P
1.5.6
Capacitors bridging insulation
Evaluated in approved
adapter
adapter
N/A
1.5.7
Resistors bridging insulation
Evaluated in approved
adapter
adapter
N/A
1.5.7.1
Resistors bridging functional, basic or
supplementary insulation
supplementary insulation
N/A
1.5.7.2
Resistors bridging double or reinforced insulation
between a.c. mains and other circuits
between a.c. mains and other circuits
N/A
1.5.7.3
Resistors bridging double or reinforced insulation
between a.c. mains and antenna or coaxial cable
between a.c. mains and antenna or coaxial cable
N/A
1.5.8
Components in equipment for IT power systems
N/A
1.5.9
Surge suppressors
Evaluated in approved
adapter
adapter
N/A
1.5.9.1
General
N/A
1.5.9.2
Protection of VDRs
N/A
1.5.9.3
Bridging of functional insulation by a VDR
N/A
1.5.9.4
Bridging of basic insulation by a VDR
N/A
Page 9 of 88 Report No. EFSN13070129E-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1C
1.5.9.5
Bridging of supplementary, double or reinforced
insulation by a VDR
insulation by a VDR
N/A
1.6
Power interface
P
1.6.1
AC power distribution systems
Not directly connected to AC
mains also evaluated in
approved adapter
mains also evaluated in
approved adapter
N/A
1.6.2
Input current
(see appended table 1.6.2)
P
1.6.3
Voltage limit of hand-held equipment
This equipment is not
handheld equipment
handheld equipment
N/A
1.6.4
Neutral conductor
N/A
1.7
Marking and instructions
P
1.7.1
Power rating and identification markings
The required marking is
located on the outside surface
of the equipment.
located on the outside surface
of the equipment.
P
1.7.1.1
Power rating marking
See below
P
Multiple mains supply connections.........................:
N/A
Rated voltage(s) or voltage range(s) (V) .............. : 5Vdc
P
Symbol for nature of supply, for d.c. only .............. : The symbol is marked on the
label
P
Rated frequency or rated frequency range (Hz) ... :
N/A
Rated current (mA or A) ........................................ : 1.0A
P
1.7.1.2
Identification markings
See below
P
Manufacturer’s name or trade-mark or
identification mark ................................................. :
identification mark ................................................. :
JBL
P
Model identification or type reference ................... : JBL FLIP 2
P
Symbol for Class II equipment only ...................... : Class III equipment
N/A
Other markings and symbols ................................ : Additional symbols or marking
do not give rise to
misunderstanding.
misunderstanding.
P
1.7.2
Safety instructions and marking
English (Version in other
language will be provided
when submitted for national
approval)
language will be provided
when submitted for national
approval)
P
1.7.2.1
General
P
1.7.2.2
Disconnect devices
Evaluated in approved
adapter
adapter
N/A
1.7.2.3
Overcurrent protective device
N/A
1.7.2.4
IT power distribution systems
N/A
1.7.2.5
Operator access with a tool
N/A
Page 10 of 88 Report No. EFSN13070129E-1
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1C
1.7.2.6
Ozone
The equipment does not
produce Ozone.
produce Ozone.
N/A
1.7.3
Short duty cycles
The equipment is designed for
continuous operation.
continuous operation.
N/A
1.7.4
Supply voltage adjustment ................................... : No Voltage adjustment.
N/A
Methods and means of adjustment; reference to
installation instructions ......................................... :
installation instructions ......................................... :
N/A
1.7.5
Power outlets on the equipment .......................... : No standard power outlet.
N/A
1.7.6
Fuse identification (marking, special fusing
characteristics, cross-reference) .......................... :
characteristics, cross-reference) .......................... :
N/A
1.7.7
Wiring terminals
N/A
1.7.7.1
Protective earthing and bonding terminals .......... :
N/A
1.7.7.2
Terminals for a.c. mains supply conductors
N/A
1.7.7.3
Terminals for d.c. mains supply conductors
N/A
1.7.8
Controls and indicators
See below
N/A
1.7.8.1
Identification, location and marking ..................... : No safety relevant indicators,
switches and controls
provided
provided
N/A
1.7.8.2
Colours ................................................................ :
N/A
1.7.8.3
Symbols according to IEC 60417......................... :
N/A
1.7.8.4
Markings using figures ....................................... :
No figures used
N/A
1.7.9
Isolation of multiple power sources ..................... :
N/A
1.7.10
Thermostats and other regulating devices .......... :
No thermostats or other
regulating devices.
regulating devices.
N/A
1.7.11
Durability
The marking plate was
subjected to the permanence
of marking test. The marking
plate was rubbed with cloth
soaked with water for 15s and
then again for 15s with the
cloth soaked with petroleum
spirit. After this test there was
no damage to the marking
plate. The marking on the
label did not fade. There was
no curling of the marking
plate.
subjected to the permanence
of marking test. The marking
plate was rubbed with cloth
soaked with water for 15s and
then again for 15s with the
cloth soaked with petroleum
spirit. After this test there was
no damage to the marking
plate. The marking on the
label did not fade. There was
no curling of the marking
plate.
P
1.7.12
Removable parts
No removable parts provided
N/A
1.7.13
Replaceable batteries ......................................... :
No replaceable batteries
provided
provided
N/A
Language(s) ........................................................ :
See above
1.7.14
Equipment for restricted access locations ........... :
The equipment is not intended
to be use in restricted access
locations.
to be use in restricted access
locations.
N/A