JBL ES 250P (serv.man4) EMC - CB Certificate ▷ View online
Page 6 of 47
Report No. 707218
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
6
HAZARDOUS RADIATION
6.1
Ionizing radiation < 36 pA/kg (0.5 mR/h)
N/A
6.2
Laser radiation, emission limits to IEC 60825-1 .... :
N/A
Emission limits under fault conditions ................... :
N/A
7
HEATING UNDER NORMAL OPERATING CONDITIONS
(See appended table)
7.1
Temperature rises not exceeding specified values,
any single protective device defeated except those
of Cl. 7.1 a) and b)
any single protective device defeated except those
of Cl. 7.1 a) and b)
P
7.1.1
Temperature rise of accessible parts
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
P
7.1.3
Temperature rise of parts acting as a support or as
a mechanical barrier
a mechanical barrier
P
7.1.4
Temperature rise of windings
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0.2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0.2 A at least 150
o
C
Mains fuse holder (211
o
C)
P
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
PCB
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
N/A
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
P
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
P
8.5
Class I equipment
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Capacitors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
N/A
Page 7 of 47
Report No. 707218
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
8.6
Class II equipment and Class II constructions within Class I equipment
Reinforced or double insulation between hazardous
live parts and accessible parts
live parts and accessible parts
P
Components bridging reinforced or double insulation
complying with 14.1 a) or 14.3
complying with 14.1 a) or 14.3
Mains transformer
P
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
bridged by a capacitor complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with 2
capacitors in series complying with 14.2.1 a)
capacitors in series complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with a
single capacitor complying with 14.2.1 b)
single capacitor complying with 14.2.1 b)
C03, C04
P
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
N/A
8.7
This sub-clause is void
8.8
Double Insulation: the Basic or Supplementary
insulation > 0.4 mm (mm) .......................................:
insulation > 0.4 mm (mm) .......................................:
Primary wires are double
insulated
insulated
P
Reinforced insulation > 0.4 mm (mm) ....................:
N/A
Thin sheet insulation used inside the enclosure.
In mains transformer
P
Basic or supplementary insulation, at least two
layers, each meeting 10.3 dielectric
layers, each meeting 10.3 dielectric
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3 dielectric
two of which meet 10.3 dielectric
N/A
Reinforced insulation, two layers each of which meet
10.3 dielectric
10.3 dielectric
150-r1107012-e:
Two layers plastic sheet
Two layers plastic sheet
P
Reinforced insulation, three layers any two which
meet 10.3 dielectric
meet 10.3 dielectric
TT093505270-E:
Thin sheet insulation, 4 turns
mylarfoil with a thickness of
0.08mm.
Thin sheet insulation, 4 turns
mylarfoil with a thickness of
0.08mm.
P
8.9
Primary Wiring: Adequate insulation between
internal hazardous live conductors and accessible
parts
internal hazardous live conductors and accessible
parts
Applies to Class I appliances
N/A
Secondary Wiring: Adequate insulation between
internal hazardous live parts and conductors
connected to accessible parts
internal hazardous live parts and conductors
connected to accessible parts
N/A
8.10
Class II Wiring:
(1) Primary: Double insulation between conductors
connected to the mains and accessible parts.
connected to the mains and accessible parts.
(2) Secondary: Double insulation between
conductors connected to accessible parts and the
mains
conductors connected to accessible parts and the
mains
Live wires from transformer are
double insulated.
No secondary wire can come
into contact with live bare parts.
double insulated.
No secondary wire can come
into contact with live bare parts.
P
Page 8 of 47
Report No. 707218
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
8.11
Detaching of wires
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
No risk of any wire becoming
detached
detached
N/A
Vibration test carried out .........................................:
No, no need. See above
N/A
8.12
This sub-clause is void
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s)
etc. (pull test 20 N for 10 s)
N/A
8.14
Adequate fastening of covers (pull test 50 N for
10 s)
10 s)
P
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges (2N force)
due to hot parts or sharp edges (2N force)
P
8.16
Only special supply equipment can be used
N/A
8.17
Insulated winding wire without additional interleaved
insulation
insulation
N/A
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
8.19.1
Disconnect device
Mains plug
P
All-pole switch or circuit breaker with >3mm contact
separation
separation
N/A
8.19.2
Mains switch ON indication
Power ON, + green LED
P
8.20
Switch not fitted in the mains cord
N/A
8.21
Bridging components comply with clause 14
N/A
8.22
Test of non-separable thin sheet material
N/A
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
9.1
Testing on the outside
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
N/A
9.1.1.1
a) Determination of Hazardous Live parts
U1: 0.187V peak
U2: 0.165V peak
P
b) Touch current measured from terminal devices
using the network in annex D ................................ :
P
c) Discharge not exceeding 45
μC
N/A
d) Energy of discharge not exceeding 350 mJ
N/A
9.1.1.2
Test with test finger and test probe
P
9.1.2
No hazardous live shafts of knobs, handles or
levers
levers
N/A
Page 9 of 47
Report No. 707218
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
9.1.3
Ventilation holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
N/A
9.1.4
Terminal devices - within 25mm tested with
1 mm x 20 mm test pin (10 N); test probe D of IEC
61032
1 mm x 20 mm test pin (10 N); test probe D of IEC
61032
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
N/A
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after 2 s :
withdrawal of the mains plug; voltage (V) after 2 s :
<5V
P
If C is not greater than 0.1
μF no test needed
N/A
9.1.7
Enclosure sufficiently resistant to external force
a)
Test probe 11 of IEC 61032 for 10 s (50 N)
P
b)
Test hook of fig. 4 for 10 s (20 N)
P
c)
Conductive enclosure: 30 mm diameter test tool for
5 s (100 or 250 N) .................................................. :
5 s (100 or 250 N) .................................................. :
250N
P
9.2
No hazard 2s after removing a cover by hand
N/A
10
INSULATION REQUIREMENTS
10.1
Insulation resistance (M
Ω) at least 2 MΩmin. after
surge test for basic and 4 M
Ωmin. for reinforced
insulation ................................................................ :
N/A
10.2
Humidity treatment 48 h or 120 h .......................... :
Both 48 and 120h
P
10.3
Insulation resistance and dielectric strength
between mains terminals
between mains terminals
P
Insulation resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class 1)
BASIC or SUPPLEMENTARY insulation (Class 1)
N/A
Insulation resistance across REINFORCED
insulation (Class II)
insulation (Class II)
P
11
FAULT CONDITIONS
11.1
No shock hazard under fault condition
P
11.2
Heating under fault condition
P
No hazard from softening solder
P
No flaming more than 10s
P
Soldered terminations not used as protective
mechanism
mechanism
P