Report No. 707218
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
6
HAZARDOUS RADIATION
6.1
Ionizing radiation < 36 pA/kg (0.5 mR/h)
N/A
6.2
Laser radiation, emission limits to IEC 60825-1 .... :
N/A
Emission limits under fault conditions ................... :
N/A
7
HEATING UNDER NORMAL OPERATING CONDITIONS
(See appended table)
7.1
Temperature rises not exceeding specified values,
any single protective device defeated except those
of Cl. 7.1 a) and b)
P
7.1.1
Temperature rise of accessible parts
P
7.1.2
Temperature rise of parts providing electrical
insulation
P
7.1.3
Temperature rise of parts acting as a support or as
a mechanical barrier
P
7.1.4
Temperature rise of windings
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0.2 A at least 150
o
C
Mains fuse holder (211
o
C)
P
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
PCB
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
N/A
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
P
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
P
8.5
Class I equipment
Basic insulation between hazardous live parts and
earthed accessible parts
N/A
Capacitors bridging basic insulation complying with
14.2.1 a)
N/A
Page 7 of 47
Report No. 707218
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
8.6
Class II equipment and Class II constructions within Class I equipment
Reinforced or double insulation between hazardous
live parts and accessible parts
P
Components bridging reinforced or double insulation
complying with 14.1 a) or 14.3
Mains transformer
P
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with 2
capacitors in series complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with a
single capacitor complying with 14.2.1 b)
C03, C04
P
Basic insulation bridged by components complying
with 14.3.4.3
N/A
8.7
This sub-clause is void
8.8
Double Insulation: the Basic or Supplementary
insulation > 0.4 mm (mm) .......................................:
Primary wires are double
insulated
P
Reinforced insulation > 0.4 mm (mm) ....................:
N/A
Thin sheet insulation used inside the enclosure.
In mains transformer
P
Basic or supplementary insulation, at least two
layers, each meeting 10.3 dielectric
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3 dielectric
N/A
Reinforced insulation, two layers each of which meet
10.3 dielectric
150-r1107012-e:
Two layers plastic sheet
P
Reinforced insulation, three layers any two which
meet 10.3 dielectric
TT093505270-E:
Thin sheet insulation, 4 turns
mylarfoil with a thickness of
0.08mm.
P
8.9
Primary Wiring: Adequate insulation between
internal hazardous live conductors and accessible
parts
Applies to Class I appliances
N/A
Secondary Wiring: Adequate insulation between
internal hazardous live parts and conductors
connected to accessible parts
N/A
8.10
Class II Wiring:
(1) Primary: Double insulation between conductors
connected to the mains and accessible parts.
(2) Secondary: Double insulation between
conductors connected to accessible parts and the
mains
Live wires from transformer are
double insulated.
No secondary wire can come
into contact with live bare parts.
P
Page 8 of 47
Report No. 707218
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
8.11
Detaching of wires
No undue reduction of creepages or clearance
distances if wires become detached
No risk of any wire becoming
detached
N/A
Vibration test carried out .........................................:
No, no need. See above
N/A
8.12
This sub-clause is void
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s)
N/A
8.14
Adequate fastening of covers (pull test 50 N for
10 s)
P
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges (2N force)
P
8.16
Only special supply equipment can be used
N/A
8.17
Insulated winding wire without additional interleaved
insulation
N/A
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
8.19.1
Disconnect device
Mains plug
P
All-pole switch or circuit breaker with >3mm contact
separation
N/A
8.19.2
Mains switch ON indication
Power ON, + green LED
P
8.20
Switch not fitted in the mains cord
N/A
8.21
Bridging components comply with clause 14
N/A
8.22
Test of non-separable thin sheet material
N/A
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
9.1
Testing on the outside
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
N/A
9.1.1.1
a) Determination of Hazardous Live parts
U1: 0.187V peak
U2: 0.165V peak
P
b) Touch current measured from terminal devices
using the network in annex D ................................ :
P
c) Discharge not exceeding 45
μC
N/A
d) Energy of discharge not exceeding 350 mJ
N/A
9.1.1.2
Test with test finger and test probe
P
9.1.2
No hazardous live shafts of knobs, handles or
levers
N/A
Page 9 of 47
Report No. 707218
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
9.1.3
Ventilation holes tested by means of
4 mm x 100 mm test pin
N/A
9.1.4
Terminal devices - within 25mm tested with
1 mm x 20 mm test pin (10 N); test probe D of IEC
61032
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
N/A
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after 2 s :
<5V
P
If C is not greater than 0.1
μF no test needed
N/A
9.1.7
Enclosure sufficiently resistant to external force
a)
Test probe 11 of IEC 61032 for 10 s (50 N)
P
b)
Test hook of fig. 4 for 10 s (20 N)
P
c)
Conductive enclosure: 30 mm diameter test tool for
5 s (100 or 250 N) .................................................. :
250N
P
9.2
No hazard 2s after removing a cover by hand
N/A
10
INSULATION REQUIREMENTS
10.1
Insulation resistance (M
Ω) at least 2 MΩmin. after
surge test for basic and 4 M
Ωmin. for reinforced
insulation ................................................................ :
N/A
10.2
Humidity treatment 48 h or 120 h .......................... :
Both 48 and 120h
P
10.3
Insulation resistance and dielectric strength
between mains terminals
P
Insulation resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class 1)
N/A
Insulation resistance across REINFORCED
insulation (Class II)
P
11
FAULT CONDITIONS
11.1
No shock hazard under fault condition
P
11.2
Heating under fault condition
P
No hazard from softening solder
P
No flaming more than 10s
P
Soldered terminations not used as protective
mechanism
P
Page of 60