Page 3 of 47
Report No. 707218
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
Summary of testing: See Test Report
Tests performed (name of test and test clause):
See Test Report
Testing location:
See page 2
Summary of compliance with National Differences:
The sample(s) tested complies with the requirements of IEC 60065:2001 + A1
Compliance with the National requirements of the CENELEC countries as given in CB Bulletin 112A was also
confirmed. The national differences for Singapore and Korea have also been checked.
Copy of marking plate
707218 (ES250P-230)
707218 (ES250P-230)
Page 4 of 47
Report No. 707218
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
Test item particulars.................................................. :
Powered subwoofer
Classification of installation and use............................ :
-
Supply Connection....................................................... :
Mains plug with cord
......................................................................................:
......................................................................................:
Possible test case verdicts:
- test case does not apply to the test object .................: N/A (Not Applicable)
- test object does meet the requirement .......................: P (Pass)
- test object does not meet the requirement.................: F (Fail)
Testing .........................................................................:
Date of receipt of test item............................................: 25 May 2007
Date (s) of performance of tests...................................: 11 June 2007 – 14 June 2007
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a point is used as the decimal separator.
General product information:
Page 5 of 47
Report No. 707218
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
3
GENERAL REQUIREMENTS
Safety class of the apparatus ................................ :
II
P
4
GENERAL CONDITIONS OF TESTS
4.1.4
Ventilation instructions require the use of the test
box
No, not for this kind of product
N/A
5
MARKING
Comprehensible and easily discernible
P
Permanent durability against water and petroleum
spirit
P
5.1
a), b)
Identification, maker, model ................................... :
ES250P/230
P
c)
Class II symbol if applicable
P
d), e)
Rated supply voltage and symbol ......................... :
220-230V~
P
f)
Frequency if safety dependant
50/60Hz
P
g), h), i)
Rated current or power consumption .................... :
1A
P
5.2 a)
Earth terminal
N/A
b)
Hazardous live terminals
N/A
c)
Supply output terminals (other than mains)
N/A
5.3
Use of triangle with exclamation mark
In schematic diagrams
P
5.4
Instructions for use
5.4.1
a)
Mains powered equipment not exposed to dripping
or splashing. Warning concerning objects filled with
liquid, etc.
P
b)
Hazardous live terminals, instructions for wiring
N/A
c)
Instructions for replacing lithium battery
N/A
Instructions for modem if fitted
N/A
d)
Class I earth connection warning
N/A
e)
Instructions for multimedia system connection
N/A
f)
Special stability warning for fixed installation
N/A
g)
Batteries not exposed to heat/sun warning
N/A
5.4.2
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
Mains plug. Information in OM
provided
P
Instructions for permanently connected equipment
N/A
Page of 60