JBL ES 250P (serv.man4) EMC - CB Certificate ▷ View online
Page 10 of 47
Report No. 707218
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
11.2.1
Measurement of temperature rises
P
11.2.2
Temperature rise of accessible parts
P
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
P
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for
max. 5 min
exceeding the limits of table 3 by max. 100 K for
max. 5 min
N/A
a) Temperature rise of printed circuit boards (PCB)
to 20.1.3, exceeding the limits of table 3 by not more
than 100 K for an area not greater than 2 cm²
to 20.1.3, exceeding the limits of table 3 by not more
than 100 K for an area not greater than 2 cm²
N/A
b) Temperature rise of printed circuit boards (PCB)
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N/A
Class I protective earthing maintained
N/A
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
P
11.2.5
Temperature rise of windings
P
11.2.6
Temperature rise of parts not subject to the limits of
11.2.1 to 11.2.5 Table 3 e) "Other Parts"
11.2.1 to 11.2.5 Table 3 e) "Other Parts"
P
12
MECHANICAL STRENGTH
12.1.1
Bump test where mass >7 kg
P
12.1.2
Vibration test (portable, metal, musical amps)
No connection or part which
might impair safety can
become loose.
might impair safety can
become loose.
P
12.1.3
Impact hammer test
P
Steel ball test (for non-ventilated solid areas)
P
12.1.4
Drop test for portable apparatus where mass
≤7 kg
N/A
12.1.5
Thermoplastic enclosures stress relief test
N/A
12.2
Fixing of knobs, push buttons, keys and levers
P
12.3
Remote controls with hazardous live parts
N/A
12.4
Drawers (pull test 50 N, 10 s)
N/A
12.5
Antenna coaxial sockets providing isolation
N/A
12.6
Telescoping or rod antennas construction
N/A
12.6.1
Telescoping or rod antennas securement
N/A
Page 11 of 47
Report No. 707218
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
13
CLEARANCE AND CREEPAGE DISTANCES
(See appended table)
13.1
Clearances in accordance with 13.3
P
Creepage distances in accordance with 13.4
P
13.2
Determination of operating voltage
P
13.3
Clearances
13.3.2
Circuits conductively connected to the mains
comply with table 8 and, where applicable, table 9
comply with table 8 and, where applicable, table 9
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
Circuits not conductively
connected to the mains cannot
cause any shock hazard.
connected to the mains cannot
cause any shock hazard.
N/A
13.3.4
Measurement of transient voltages
N/A
13.4
Creepage distances
Creepage distances greater than table 11 minima
P
13.5
Printed boards
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N/A
13.5.2
Type B coated printed circuit boards complying with
IEC 60664-3 (basic insulation only)
IEC 60664-3 (basic insulation only)
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
N/A
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N/A
13.7
Enclosed, enveloped or hermetically sealed parts:
not conductively connected to the mains:
clearances and creepage distances as in table 12
not conductively connected to the mains:
clearances and creepage distances as in table 12
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
N/A
Page 12 of 47
Report No. 707218
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
14
COMPONENTS
14.1
Resistors
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
N/A
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
N/A
Resistors separately approved .............................. :
N/A
14.2
Capacitors and RC units
Capacitors separately approved
Yes
P
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition .. :
Y1: C03, C04
P
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition .. :
X2: C01, C02
P
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ..................... :
connected to the mains: tests for X2 ..................... :
N/A
14.2.5
a) Capacitors with volume exceeding 1750 mm³,
where short-circuit current exceeds 0.2 A:
compliance with IEC 60384-1, 4.38 category B or
better ...................................................................... :
compliance with IEC 60384-1, 4.38 category B or
better ...................................................................... :
C01, C02
P
b)
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60384-1, 4.38
category B or better ............................................... :
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60384-1, 4.38
category B or better ............................................... :
N/A
Shielded by a barrier per Table 21 ......................... :
No
N/A
14.3
Inductors and windings
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
P
14.3.1
Transformers and inductors marked with
manufacturer's name and type .............................. :
manufacturer's name and type .............................. :
Transtec TT0930505270-E alt.
Zhong Shan Yi Qi 150-r1107012-e
Zhong Shan Yi Qi 150-r1107012-e
P
Transformers and inductors separately approved :
No
N/A
14.3.2
General
14.3.3, 14.3.4.1 and 14.3.5.1
P
14.3.3
Constructional requirements (complete appended tables or include manufacturers
constructional insulation descriptions)
constructional insulation descriptions)
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
P
14.3.3.2
Transformers meet the constructional requirements
P
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Primary – secondary distances:
TT0930505270-E: 17mm
150-r1107012-e: 10mm
TT0930505270-E: 17mm
150-r1107012-e: 10mm
P
Coil formers and partition walls = 0.4 mm
N/A
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
N/A
Page 13 of 47
Report No. 707218
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
14.3.4.3
Separating transformers with at least basic
insulation
insulation
N/A
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Iron core is floating inside the
transformer (toroidal transf)
transformer (toroidal transf)
N/A
Coil formers and partition walls = 0.4 mm
N/A
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.4
High voltage components
High-voltage components and assemblies: U > 4 kV
(peak) separately approved
(peak) separately approved
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N/A
14.5
Protective devices
Protective devices used within their ratings
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
P
14.5.1.1
a) Thermal cut-outs separately approved
ST-22 (in TT0930505270-E)
N/A
b) Thermal cut-outs tested as part of the submission
N/A
14.5.1.2
a) Thermal links separately approved
A4-5A-F (in 150-r1107012-e)
P
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
N/A
14.5.2.1
Fuse-links in the mains circuit according to
IEC 60127
IEC 60127
P
14.5.2.2
Correct marking of fuse-links adjacent to holder ... :
Fuse T 2.5A L/250V
P
14.5.2.3
Not possible to connect fuses in parallel ............... :
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ........ :
replacing fuse-links without the use of a tool ........ :
Tools are required
P
14.5.3
PTC-S thermistors comply with IEC 60730-1
N/A
PTC-S devices (15 W) category V-1 or better
N/A