Page 14 of 47
Report No. 707218
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
14.5.4
Circuit protectors have adequate breaking capacity
and their position is correctly marked
P
14.6
Switches
14.6.1 a)
Separate testing to IEC 61058 including:
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3
V-0 compliance with annex G, G.1.1
and
Peak inrush rating of switch
Measured/calculated inrush…………………………:
Mains switch
Calculated inrush current with
transformer type:
150-r1107012-e: 31.5A
TT0930505270-E: 39A
P
14.6.1 b)
Tested in the apparatus:
N/A
Switch controlling > 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4
and V-0 in annex G, G.1.1
N/A
Switch controlling > 0.2A with open contact voltage
< 35 V (peak)/24 V dc complying with 14.6.3 and V-
0 in annex G, G.1.1
N/A
Switch controlling = 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.4 and V-
0 in annex G, G.1.1
N/A
14.6.2
Switch tested to 14.6.1 b) constructed to IEC
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
N/A
14.6.3
Switch tested to 14.6.1 b) compliant with IEC
61058-1 subclause 16.2.2 d), l) and m) not attaining
excessive temperatures in use
N/A
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
N/A
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 61058-1
N/A
Socket outlet current marking correct
N/A
14.7
Safety interlocks
Safety interlocks to 2.8 of IEC 60950
N/A
14.8
Voltage setting devices
Voltage setting device not likely to be changed
accidentally
N/A
Page 15 of 47
Report No. 707218
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
14.9
Motors
14.9.1
Endurance test on motors
N/A
Motor start test
N/A
Dielectric strength test
N/A
14.9.2
Not adversely affected by oil or grease etc.
N/A
14.9.3
Protection against moving parts
N/A
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950, Annex B
N/A
14.10
Batteries
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
N/A
14.10.2
No possibility of recharging non-rechargeable
batteries
N/A
14.10.3
Recharging currents and times within manufacturers
limits
N/A
Lithium batteries discharge and reverse currents
within the manufacturers limits
N/A
14.10.4
Battery mould stress relief
N/A
14.10.5
Battery drop test
N/A
14.11
Optocouplers
Optocouplers comply with Cl. 8
N/A
N/A
14.12
Surge suppression varistors
Comply with IEC 61051-2
N/A
Not connected between mains and accessible parts
except for earthed parts of permanently connected
apparatus
N/A
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12
N/A
Page 16 of 47
Report No. 707218
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
15
TERMINALS
15.1.1
Mains plug, appliance inlet, interconnection
couplers and mains socket-outlet meet the cross-
sectional area specified in 16.2 for external cords
Mains plug, appliance inlet
P
15.1.2
Connectors for antenna, earth, audio, video or data:
No risk of insertion in mains socket-outlets
P
No risk of insertion into audio or video-outlets
marked with the symbol of 5.2
N/A
15.1.3
Output terminals of a.c. adaptors or similar devices
not compatible with household mains socket-outlets
N/A
15.2
Provision for protective earthing
Accessible conductive parts of Class I equipment
reliably connected to earth terminal, within
equipment
N/A
Protective earth conductors correctly coloured
N/A
Equipment with non-detachable mains cord
provided with separate protective earth terminal
near mains input
N/A
Earthing connection of parts removable by hand.
N/A
Protective earth terminal resistant to corrosion
N/A
Earth resistance test: < 0.1
at 25 A .................. :
N/A
15.3
Terminals for external flexible cords and for permanent connection to the mains supply
15.3.1
Adequate terminals for connection of permanent
wiring
Appliance inlet
N/A
15.3.2
Reliable connection of non-detachable cords:
Not soldered to conductors of a printed circuit board
N/A
Adequate clearances and creepage distances
between connections should a wire break away
N/A
Wire secured by additional means to the conductor
N/A
15.3.3
Screws and nuts clamping conductors have
adequate threads: ISO 261, ISO 262 or similar
N/A
15.3.4
Soldered conductors wrapped around terminal prior
to soldering or held in place by additional means
N/A
Clamping of conductor and insulation if not soldered
or held by screws
N/A
15.3.5
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current of
the equipment
N/A
15.3.6
Terminals to 15.3.3 have sizes required by table 16
N/A
Page 17 of 47
Report No. 707218
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
15.3.7
Terminals clamp conductors between metal and
have adequate pressure
N/A
Terminals designed to avoid conductor slipping out
when tightened or loosened
N/A
Terminals adequately fixed to avoid loosening when
the clamping is tightened or loosened and stress on
internal wiring is avoided
N/A
15.3.8
Terminals carrying a current more than 0.2 A:
contact pressure not transmitted by insulating
material except ceramic
N/A
15.3.9
Termination of non-detachable cords/wires
terminated near to each other
N/A
Terminals located and shielded: test with 8 mm
strand
N/A
15.4
Devices forming a part of the mains plug
15.4.1
No undue strain on mains socket-outlets
N/A
15.4.2
Device complies with standard for dimensions of
mains plugs
N/A
15.4.3
Device has adequate mechanical strength
(tests a, b, c)
N/A
16
EXTERNAL FLEXIBLE CORDS
16.1
Mains cords sheathed type, complying with
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ........................................................... :
IEC 60227
P
Non-detachable cords for Class I have green/yellow
core for protective earth
N/A
16.2
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the
equipment
2x0.75mm
2
P
16.3
a) Flexible cords not complying with 16.1, used for
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
N/A
b) Flexible cords not complying with 16.1, withstand
bending and mechanical stress (3.2 of IEC 60227-2)
N/A
16.4
Flexible cords used for connection between
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
N/A