JBL ES 250P (serv.man4) EMC - CB Certificate ▷ View online
Page 30 of 47
Report No. 707218
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
Group differences
IEC 60065:2001 + A1
CB Bulletin 112A / GRP 06 II
Contents
Add the following annexes:
Annex ZB (nominative) Special national conditions
Annex ZC (informative) A-deviations
P
3.1
Add the following indent at the end of the list
-
Exposure to excessive sound pressures
from headphones or earphones
from headphones or earphones
NOTE A new method of measurement is described in
EN 50332-1, Sound system equipment: Headphones
and earphones associated
with portable audio equipment – Maximum sound
pressure level measurement methodology and limit
considerations – Part 1: General
method for ”one package equipment”, and in EN
50332-2, Sound system equipment: Headphones and
earphones associated with
portable audio equipment – Maximum sound pressure
level measurement methodology and limit
considerations – Part 2: Guidelines to
associate sets with headphones coming from different
manufacturers.
EN 50332-1, Sound system equipment: Headphones
and earphones associated
with portable audio equipment – Maximum sound
pressure level measurement methodology and limit
considerations – Part 1: General
method for ”one package equipment”, and in EN
50332-2, Sound system equipment: Headphones and
earphones associated with
portable audio equipment – Maximum sound pressure
level measurement methodology and limit
considerations – Part 2: Guidelines to
associate sets with headphones coming from different
manufacturers.
P
4.1.1
Replace the text of the note by:
NOTE For ROUTINE TEST reference is made to EN
50333
50333
.
P
5.1.i)
Add the following note:
NOTE
For RATED POWER CONSUMPTION
mesurements of TVs reference is made to EN 60107.
N/A
Page 31 of 47
Report No. 707218
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
6.1
Replace the entire subclause by:
Apparatus including a potential source of ionizing
radiation shall be so constructed that personal
protection against ionizing radiation is provided
under normal operating conditions and under fault
conditions.
Compliance is checked by measurement under
the following conditions:
In addition to the normal operating conditions, all
controls adjustable from the outside BY HAND,
by any object such as a tool or a coin, and those
internal adjustments or pre-sets which are not
locked in a reliable manner, are adjusted so as to
give maximum radiation whilst maintaining an
intelligible picture for 1 h, at the end of which the
measurement is made.
Apparatus including a potential source of ionizing
radiation shall be so constructed that personal
protection against ionizing radiation is provided
under normal operating conditions and under fault
conditions.
Compliance is checked by measurement under
the following conditions:
In addition to the normal operating conditions, all
controls adjustable from the outside BY HAND,
by any object such as a tool or a coin, and those
internal adjustments or pre-sets which are not
locked in a reliable manner, are adjusted so as to
give maximum radiation whilst maintaining an
intelligible picture for 1 h, at the end of which the
measurement is made.
N/A
13.3.1
Delete note 4.
P
14
Delete note 4 and note 5.
P
15.1.1
Delete notes 1 and 2.
P
15.2
Delete note 2.
P
16.1
Delete note 1.
P
16.2
Delete the note.
P
20
Delete note 2.
P