JBL ES 250P (serv.man4) EMC - CB Certificate ▷ View online

Page 30 of 47
Report No. 707218
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
Group differences
IEC 60065:2001 + A1
CB Bulletin 112A / GRP 06 II
Contents
Add the following annexes:
Annex ZB (nominative) Special national conditions
Annex ZC (informative) A-deviations
P
3.1
Add the following indent at the end of the list
-
Exposure to excessive sound pressures
from headphones or earphones
NOTE A new method of measurement is described in
EN 50332-1, Sound system equipment: Headphones
and earphones associated
with portable audio equipment – Maximum sound
pressure level measurement methodology and limit
considerations – Part 1: General
method for ”one package equipment”, and in EN
50332-2, Sound system equipment: Headphones and
earphones associated with
portable audio equipment – Maximum sound pressure
level measurement methodology and limit
considerations – Part 2: Guidelines to
associate sets with headphones coming from different
manufacturers.
P
4.1.1
Replace the text of the note by:
NOTE For ROUTINE TEST reference is made to EN
50333
.
P
5.1.i)
Add the following note:
NOTE
For RATED POWER CONSUMPTION
mesurements of TVs reference is made to EN 60107.
N/A
Page 31 of 47
Report No. 707218
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
6.1
Replace the entire subclause by:
Apparatus including a potential source of ionizing
radiation shall be so constructed that personal
protection against ionizing radiation is provided
under normal operating conditions and under fault
conditions.
Compliance is checked by measurement under
the following conditions:
In addition to the normal operating conditions, all
controls adjustable from the outside BY HAND,
by any object such as a tool or a coin, and those
internal adjustments or pre-sets which are not
locked in a reliable manner, are adjusted so as to
give maximum radiation whilst maintaining an
intelligible picture for 1 h, at the end of which the
measurement is made.
N/A
13.3.1
Delete note 4.
P
14
Delete note 4 and note 5.
P
15.1.1
Delete notes 1 and 2.
P
15.2
Delete note 2.
P
16.1
Delete note 1.
P
16.2
Delete the note.
P
20
Delete note 2.
P
Page 32 of 47
Report No. 707218
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
Annex B
Replace note 1 by:
In the CENELEC countries listed in IEC 62151,
special national conditions apply.
N/A
Annex G
Delete the note.
P
Annex J.2
Delete the notes of Table J.1.
N/A
Annex N
Add after the introduction:
For ROUTINE TEST reference is made to EN
50333.
P
Bibliography
Add the following standards:
EN 60332-1: 2000, Sound system equipement: Headphones and earphones
associated with portable audio equipment –
Maximum sound pressure level measurement methodology and limit
considerations – Part 1: General method for ”one package equipment”.
PrEN 50332-2 (uder consideration), Sound system equipement: Headphones and
earphones associated with portable
audio equipment – Maximum sound pressure level measurement methodology
and limit considerations – Part 2:
Guidelines to associate sets with headphones coming from different
manufacturers.
Add the following notes for the standards indicated:
IEC 60130
NOTE
Parts 9 and 17: 1998 are harmonized as Ens (not modified).
IEC 60169
NOTE
Partly harmonized in the EN 60169/HD 134 series (not modified).
IEC 60173
NOTE
Harmonized as HD 27 S1: 1978 (not modified).
IEC 60335-2-56
NOTE
Harmonized as EN 60335-2-56: 1997 (not modified).
IEC 60335-2-82
NOTE
Harmonized as EN 60335-2-82: 2000 (not modified).
IEC 60695
NOTE
Harmonized as EN 60695 series (not modified).
IEC 61040
NOTE
Harmonized as EN 61040: 1992 (not modified).
IEC 61558-2-1
NOTE
Harmonized as EN 61558-2-1: 1997 (not modified).
IEC 61558-2-4
NOTE
Harmonized as EN 61558-2-4: 1997 (not modified).
IEC 61558-2-6
NOTE
Harmonized as EN 61558-2-6: 1997 (not modified).
P
Page 33 of 47
Report No. 707218
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
Annex ZA
(normative)
Other international publications quoted in this standard with the references of the relevant European
publications
This European Standard incorporates by dated or undated reference, provisions from other
publications. These normative references are cited at the appropriate places in the text and the
publications are listed hereafter. For dated references, subsequent amendments to or revisions
of any of these publications apply to this European Standard only when incorporated in it by
amendment or revision. For undated references the latest edition of the publication referred to
applies (including amendments).
NOTE When an international standard has been modified by common modification, indicated by (mod), the
relevant EN/HD applies.
P
Page of 60
Display