Page 22 of 47
Report No. 707218
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
7.1
TABLE: temperature rise measurements: Conditions
Test performed with Mains transformer type TT0930505270-E
P
Power consumption in the OFF/Stand-by mode of
the functional switch (W)………..….:…………....:
0W / No stand-by mode
P
Cond.
Un (V)
Hz
In (A)
Pn (W)
V out
Pout (W)
Operating Condition
1
198
50
0.28
38
10
25
2
253
50
0.32
43
13
42
1/8 of max non-clipping output
power (pink noise).
LFE mode.
Loudspeaker impedance (
Ω) ................................. :
4
Several loudspeaker systems
Marking of loudspeaker terminals
-
Temperature Rise dT of Part
dT (K)
Limit max dT (K)
Test Condition No.
No 2
No ___
No ___
Transformer steel washer
24
--
Supply wiring insulation
(not under mechanical stress)
17
60 (50)
Heat sink supported by PCB
37
85 (75)
PCB (D123)
36
85 (75)
Rear panel outside of heat sink
(metal, likely to be touched)
25
40 (30)
Rear Enclosure (wood)
7
60 (50)
Knobs (plastic)
<15
50 (40)
27
--
Winding temperature rise measurements
Ambient temperature t1 (
o
C) ................................
Ambient temperature t2 (
o
C) ................................
23
23
Temperature rise dT of winding:
dT = (R
2
– R
1
) x (234.5 + t1) – (t2 – t1)
R
1
R
1
(
Ω)
R
2
(
Ω)
dT (K)
Limit
maxK)
Insulation class
Mains transformer primary wiring
4.642
5.143
28
85 (75)
E
Secondary wiring, yellow – black
0.222
0.245
27
85 (75)
E
Secondary wiring, red – black
0.548
0.605
27
85 (75)
E
The limit values in parenthesis are the limit values for tropical climate.
Page 23 of 47
Report No. 707218
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
7.1
TABLE: temperature rise measurements: Conditions
Test performed with Mains transformer type 150-e1107012-e
P
Power consumption in the OFF/Stand-by mode of
the functional switch (W)………..….:…………....:
0W / No stand-by mode
P
Cond.
Un (V)
Hz
In (A)
Pn (W)
V out
Pout (W)
Operating Condition
1
198
50
0.32
41
11.1
31
2
253
50
0.4
65
15.2
58
1/8 of max non-clipping output
power (pink noise).
Normal mode.
Loudspeaker impedance (
Ω) ................................. :
4
Several loudspeaker systems
Marking of loudspeaker terminals
-
Temperature Rise dT of Part
dT (K)
Limit max dT (K)
Test Condition No.
No 2
No ___
No ___
Transformer steel washer
41
--
Supply wiring insulation
(not under mechanical stress)
22
60 (50)
Heat sink supported by PCB
39
85 (75)
PCB (Primary board)
25
85 (75)
Rear panel outside of heat sink
(metal, likely to be touched)
29
40 (30)
Rear Enclosure (wood)
12
60 (50)
Knobs (plastic)
15
50 (40)
26
--
Winding temperature rise measurements
Ambient temperature t1 (
o
C) ................................
Ambient temperature t2 (
o
C) ................................
24
28
Temperature rise dT of winding:
dT = (R
2
– R
1
) x (234.5 + t1) – (t2 – t1)
R
1
R
1
(
Ω)
R
2
(
Ω)
dT (K)
Limit
maxK)
Insulation class
Mains transformer primary wiring
6.418
7.733
49
85 (75)
E
Secondary wiring, yellow – yellow
0.4801
0.571
45
85 (75)
E
Secondary wiring, red – red
1.2097
1.438
45
85 (75)
E
The limit values in parenthesis are the limit values for tropical climate.
Page 24 of 47
Report No. 707218
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
9.1
Shock Hazard
P
Under normal operating conditions: > 35Vpk ac / 60V dc
Notes: Reference Annex D
-
CLASS I: (single phase)
AC
DC
U1:
Vpk
mA rms
U1:
V
mA
U2:
Vpk
mA rms
CLASS II: (single phase)
U1:
0.187Vpk
mA rms
U1:
V
mA
U2:
0.165Vpk
mA rms
10.3
TABLE: Insulation Resistance Measurements
P
Insulation resistance R between:
R (M
Ω)
Min
required R
(M
Ω)
Between mains poles (primary fuse disconnected)
>10
2
Between parts separated by basic or supplementary insulation
-
2
Between parts separated by double or reinforced insulation
>10
4
10.3
TABLE: Electric Strength Measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Mains poles (primary fuse disconnected)
2120
No
Between parts separated by basic or supplementary insulation
-
-
Between parts separated by double or reinforced insulation
4240
No
Page 25 of 47
Report No. 707218
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
11.2
TABLE: summary of fault condition tests
P
Voltage (V) 0.9 or 1.1 times rated voltage .............:
220-230
Frequency (Hz)……………………………………..:
50/60
Ambient temperature (
o
C) .......................................:
25
No
Component
Fault
Temp Rise/
Component
Other results
(include description and test duration)
1a
Apparatus
with
transformer
TT0930505270-E
Max amp.
power output
Primary winding:
81K
Secondary winding:
76K
Transf ormer washer:
68K
Rear encl.(wood):
12K
PCB (heat sink):
57K
PCB (D123):
83K
90K/PCB (R224):
90K
48K
Rear metal encl.
38K
Un = 253V, Pn = 220W, In = 1.3A Max
U
out
= 37V
Test was interrupted after 4h.
No hazard.
1b
Apparatus
with
transformer
150-r1107012-e
Max amp.
power output
Transf ormer washer:
45K
Rear encl.(wood):
13K
PCB (heat sink):
48K
PCB (main board):
27K
27K
Rear metal encl.:
32K
Un=253V
Apparatus broke down and Mains fuse
blew after 7 minutes.
No hazard.
2
C19
sc
-
Un = 198V
F1 opened immediately. Q11 damaged.
No hazard.
3
Q11 (d-g)
sc
-
Un = 198V
F1 opened immediately. Q10, Q10B, Q11
damaged. No hazard.
4
R6
d
-
Un = 253V, Pn = 111-172W, I
F1
=0.6-0.9A
within 2min the apparatus switched to
standby mode. Test time 2min. No hazard.
Page of 60