JBL ES 150PW (serv.man4) EMC - CB Certificate ▷ View online
ELECTRONICS TESTING CENTER(ETC), TAIWAN
File No. : 08-07-RBF-038-01
EMC TESTING DEPARTMENT II
Page: 40 / 42
4.2.5.2 RF Common Mode Immunity Test Setup Photos :
ELECTRONICS TESTING CENTER(ETC), TAIWAN
File No. : 08-07-RBF-038-01
EMC TESTING DEPARTMENT II
Page: 41 / 42
4.2.6 Voltage Interruptions and Voltage Dips Immunity Test :
4.2.6.1 Voltage Interruptions and Voltage Dips Immunity Test Data:
Operating Conditions of The EUT : Operation Mode
Test Date : Jul. 08, 2008
Test Specification
EN 61000-4-11:2004
Equipment
Manufacturer
Model No.
Calibration Date
Next Cal. Date
EMC Immunity Tester
EMC-PARTNER
TRANSIENT-1000
2007/12/13
2008/12/12
Climatic Condition
Ambient Temperature: 23 °C Relative
Humidity:
51 %RH
Atmospheric Pressure : 990 mbar
Power Supply System
AC Power : 230 Vac 50 Hz
Test Set-up
Floor-standing Equipment
Test mode
Voltage
dips
Durations
(Periods)
Interval(s)
Times Phase Result
Voltage interruptions
>95%
250
10
12
0
o
/180
o
A
>95% 0.5 10 12 0
o
/180
o
A
>95% 1 10 12
0
o
/180
o
A
Voltage dips in %U
T
70% 25 10 12
0
o
/180
o
A
Note :
“ A ” means the EUT function was correct during the test.
ELECTRONICS TESTING CENTER(ETC), TAIWAN
File No. : 08-07-RBF-038-01
EMC TESTING DEPARTMENT II
Page: 42 / 42
4.2.6.2 Voltage Interruptions and Voltage Dips Immunity Test Setup Photos :
ELECTRONICS TESTING CENTER(ETC), TAIWAN
File No. : 08-07-RBF-038-01
EMC TESTING DEPARTMENT II
Page: 1 / 9
CONSTRUCTED PHOTOS of EUT
1. Front View of EUT
2. Side View of EUT
Click on the first or last page to see other ES 150PW (serv.man4) service manuals if exist.