JBL ES 150PW (serv.man4) EMC - CB Certificate ▷ View online
ELECTRONICS TESTING CENTER(ETC), TAIWAN
File No. : 08-07-RBF-038-01
EMC TESTING DEPARTMENT II
Page: 36 / 42
4.2.3.2 EFT/Burst Immunity Test Setup Photos:
ELECTRONICS TESTING CENTER(ETC), TAIWAN
File No. : 08-07-RBF-038-01
EMC TESTING DEPARTMENT II
Page: 37 / 42
4.2.4 Surge Immunity Test :
4.2.4.1 Surge Immunity Test Data:
Operating Conditions of The EUT : Operation Mode
Test Date : Jul. 08, 2008
Test Specification
EN 61000-4-5:1995/A1:2001
Equipment
Manufacturer
Model No.
Calibration Date
Next Cal. Date
EMC Immunity Tester
EMC-PARTNER
TRANSIENT-1000
2007/12/13
2008/12/12
Climatic Condition
Ambient Temperature: 23 °C Relative
Humidity:
51 %RH
Atmospheric Pressure : 990 mbar
Power Supply System
AC Power : 230 Vac 50 Hz
Test Set-up
Floor-standing Equipment
Waveform : 1.2/50
µs(8/20µs)
Repetition rate : 60 sec
Times : 5 time/each condition
\Phase
\Voltage \Mode \Polarity \Result
0
o
90
o
180
o
270
o
+
A A A A
0.5 kV
L
− N
−
A A A A
+
A A A A
1.0 kV
L
− N
−
A A A A
Note :
“ A ” means the EUT function was correct during the test.
ELECTRONICS TESTING CENTER(ETC), TAIWAN
File No. : 08-07-RBF-038-01
EMC TESTING DEPARTMENT II
Page: 38 / 42
4.2.4.2 Surge Immunity Test Setup Photos :
ELECTRONICS TESTING CENTER(ETC), TAIWAN
File No. : 08-07-RBF-038-01
EMC TESTING DEPARTMENT II
Page: 39 / 42
4.2.5 RF Common Mode Immunity Test :
4.2.5.1 RF Common Mode Immunity Test Data:
Operating Conditions of The EUT : Operation Mode
Test Date : Jul. 08, 2008
Test Specification
EN 61000-4-6:1996/A1:2001
Equipment
Manufacturer
Model No.
Calibration Date
Next Cal. Date
CS TESTER
FRANKONIA
CIT-10
2007/09/05
2008/09/04
M2+3 CDN-KIT
FRANKONIA
M2+3
2007/09/08
2008/09/07
SCHAFFUER CS-CLAMP KEMZ801 2007/09/08 2008/09/07
Climatic Condition
Ambient Temperature: 25 °C Relative
Humidity:
57 %RH
Atmospheric Pressure : 990 mbar
Power Supply System
AC Power : 230 Vac 50 Hz
Test Set-up
Floor-standing Equipment
Frequency Range
:
0.15 MHz ~ 80 MHz
Field Strength
:
3 V/m
Modulation (AM 1kHz 80%)
Sweep Rate :
≤ 1.5×10
-3
decades/s
Step Size :
≤ 1 % of preceding frequency value Dwell Time :2.9 s
Frequency Range (MHz)
Tested Line
Test Result
0.15~80
Power Line (M2)
A
Note :
“ A ” means the EUT function was correct during the test.