4.2.1.2 Electrostatic Discharge Immunity Test Setup Photos :
ELECTRONICS TESTING CENTER(ETC), TAIWAN
File No. : 08-07-RBF-038-01
EMC TESTING DEPARTMENT II
Page: 33 / 42
4.2.2 RF Radiated Fields Immunity Test :
4.2.2.1 RF Radiated Fields Immunity Test Data:
Operating Conditions of The EUT : Operation Mode
Test Date : Jul. 08, 2008
Test Specification
EN 61000-4-3:2006
Equipment
Manufacturer
Model No.
Calibration Date
Next Cal. Date
Antenna
AR
AT5080
N/A
N/A
signal Generator
Aglient
E4421B
2007/07/04
2008/07/03
Amplifier Ophir 5172
N/A
N/A
Amplifier Ophir 5127
N/A
N/A
POWER METER
Booton
4232A 2007/07/04
2008/07/03
Climatic Condition
Ambient Temperature: 25 °C Relative
Humidity:
57 %RH
Power Supply System
AC Power : 230 Vac 50 Hz
Test Set-up
Floor-standing Equipment
EUT
Interfere source
Horizontal/Vertical
Frequency Range:
80 MHz ~ 2700 MHz Field
Strength:
3
V/m
Modulation (AM 1kHz 80%)
Sweep Rate
:
≤ 1.5×10-3 decades/s Step Size
:
≤ 1 % of preceding frequency value Dwell time
:
2.9 s
Frequency Range (MHz)
Antenna-Polarization
Direction of Device
Test Result
front A
rear A
left A
80-1000 1400-2700
Horizontal
right A
front A
rear A
left A
80-1000 1400-2700
Vertical
right A
Note : “ A ” means the EUT function was correct during the test.
ELECTRONICS TESTING CENTER(ETC), TAIWAN
File No. : 08-07-RBF-038-01
EMC TESTING DEPARTMENT II
Page: 34 / 42
4.2.2.2 RF Radiated Fields Immunity Test Setup Photos :
ELECTRONICS TESTING CENTER(ETC), TAIWAN
File No. : 08-07-RBF-038-01
EMC TESTING DEPARTMENT II
Page: 35 / 42
4.2.3 EFT/Burst Immunity Test :
4.2.3.1 EFT/Burst Immunity Test Data:
Operating Conditions of The EUT : Operation Mode
Test Date : Jun.02, 2008
Test Specification
EN 61000-4-4:2004
Equipment
Manufacturer
Model No.
Calibration Date
Next Cal. Date
EMC Immunity Tester
EMC-PARTNER
TRANSIENT-1000
2007/12/13
2008/12/12
Climatic Condition
Ambient Temperature: 23 °C Relative
Humidity:
51 %RH
Atmospheric Pressure : 990 mbar
Power Supply System
AC Power : 230 Vac 50 Hz
Test Set-up
Floor-standing Equipment
Pulse :5/50ns
Burst :15m/300ms
Repetition Rate: 5kHz
Test time: 1 min/each condition
1.0 kV
\Voltage\Polarity\
\Test Point\Mode\Result\
+ -
L B
B
Power Line
N B
B
L – N
B
B
Note : “ A ” means the EUT function was correct during the test.
“ B” means the EUT’s function was interrupted during the test. After test, the EUT
operate as intended without operator intervention.