JBL ES 150PW (serv.man4) EMC - CB Certificate ▷ View online
ELECTRONICS TESTING CENTER(ETC), TAIWAN
File No. : 08-07-RBF-038-01
EMC TESTING DEPARTMENT II
Page: 20 / 42
Mode : AV In -HOR
Meter Reading
( dBuV )
Results
( dBuV/m )
Emission
Frequency
( MHz)
HOR.
CORR'd
Factor
( dB )
HOR.
Limit
(dBuV/m)
Margins
( dB )
148.970 32.0
-12.4
19.6 30.0
-10.4
157.370 33.8
-13.1
20.7 30.0
-9.3
184.470 34.1
-14.1
20.0 30.0
-10.0
318.200 31.5 -8.3
23.2 37.0
-13.8
343.400 34.2
-10.4
23.8 37.0
-13.2
368.600 30.8 -7.6
23.2 37.0
-13.8
Mode : AV In -VER
Meter Reading
( dBuV )
Results
( dBuV/m )
Emission
Frequency
( MHz)
VER.
CORR'd
Factor
( dB )
VER.
Limit
(dBuV/m)
Margins
( dB )
148.970 30.5
-12.4
18.1 30.0
-11.9
157.370 30.7
-13.1
17.6 30.0
-12.4
184.470 33.1
-14.1
19.0 30.0
-11.0
318.200 29.9 -8.3
21.6 37.0
-15.4
343.400 32.1
-10.4
21.7 37.0
-15.3
368.600 28.5 -7.6
20.9 37.0
-16.1
Notes: 1) Place of Measurement: Measuring site of the ETC
2) Measurement Distance: 10 m
3) Height of table on which the EUT was placed: 0.8 m
4) Height of Receiving Antenna: 1 - 4 m
5) Remark “----“ means that the emissions level is too low to be measured.
6) The expanded uncertainty of the radiated emission tests is 3.53 dB.
ELECTRONICS TESTING CENTER(ETC), TAIWAN
File No. : 08-07-RBF-038-01
EMC TESTING DEPARTMENT II
Page: 21 / 42
Operating Conditions of The EUT : Link In
Test Date : Jun. 10, 2008
Test Specification
EN 55022:2006(Class B)
Equipment
Manufacturer
Model No.
Calibration Date
Next Cal. Date
Test Receiver
Rohde & Schwarz ESCS
30
2008/01/30 2009/01/29
Amplifier HP 8447D
2007/09/20
2008/09/19
Spectrum Advantest R3162
2008/01/29
2009/01/28
Bi-Log Antenna
Schaffner
CBL 6111
2008/05/24
2009/05/23
Climatic Condition
Ambient Temperature: 21 °C Relative
Humidity:
54 %RH
Power Supply System
AC Power : 230 Vac 50 Hz
Test Set-up
Floor-standing Equipment
Test data see the next pages.
ELECTRONICS TESTING CENTER(ETC), TAIWAN
File No. : 08-07-RBF-038-01
EMC TESTING DEPARTMENT II
Page: 22 / 42
Mode : Link In -HOR
Meter Reading
( dBuV )
Results
( dBuV/m )
Emission
Frequency
( MHz)
HOR.
CORR'd
Factor
( dB )
HOR.
Limit
(dBuV/m)
Margins
( dB )
49.240 34.3
-18.5
15.8
30.0
-14.2
159.540 33.5
-13.4
20.1 30.0
-9.9
171.730 34.9
-13.7
21.2 30.0
-8.8
343.400 33.2
-10.4
22.8 37.0
-14.2
368.600 30.1 -7.6
22.5 37.0
-14.5
428.100 28.3 -5.0
23.3 37.0
-13.7
Mode : Link In -VER
Meter Reading
( dBuV )
Results
( dBuV/m )
Emission
Frequency
( MHz)
VER.
CORR'd
Factor
( dB )
VER.
Limit
(dBuV/m)
Margins
( dB )
49.240 35.9
-18.5
17.4
30.0
-12.6
159.540 33.0
-13.4
19.6 30.0
-10.4
171.730 32.5
-13.7
18.8 30.0
-11.2
343.400 31.0
-10.4
20.6 37.0
-16.4
368.600 29.0 -7.6
21.4 37.0
-15.6
428.100 25.1 -5.0
20.1 37.0
-16.9
Notes: 1) Place of Measurement: Measuring site of the ETC
2) Measurement Distance: 10 m
3) Height of table on which the EUT was placed: 0.8 m
4) Height of Receiving Antenna: 1 - 4 m
5) Remark “----“ means that the emissions level is too low to be measured.
6) The expanded uncertainty of the radiated emission tests is 3.53 dB.
ELECTRONICS TESTING CENTER(ETC), TAIWAN
File No. : 08-07-RBF-038-01
EMC TESTING DEPARTMENT II
Page: 23 / 42
4.1.2.2 Radiated Emissions Test Setup Photos:
Click on the first or last page to see other ES 150PW (serv.man4) service manuals if exist.