JBL ES 150PW (serv.man4) EMC - CB Certificate ▷ View online
ELECTRONICS TESTING CENTER(ETC), TAIWAN
File No. : 08-07-RBF-038-01
EMC TESTING DEPARTMENT II
Page: 24 / 42
4.1.3 Harmonics Current Emissions Test :
4.1.3.1 Harmonics Current Emissions Test Data:
Operating Conditions of The EUT : Operation Mode
Test Date : Jun. 02, 2008
Test Specification
EN 61000-3-2:2006
Equipment
Manufacturer
Model No.
Calibration Date
Next Cal. Date
Hormonics-1000 EMC-Partner Hormonics-1000 2007/11/30
2008/11/29
Climatic Condition
Ambient Temperature: 22 °C Relative
Humidity:
50 %RH
Power Supply System
AC Power : 230 Vac 50 Hz
Test Set-up
Floor-standing Equipment
Test data see the next pages.
ELECTRONICS TESTING CENTER(ETC), TAIWAN
File No. : 08-07-RBF-038-01
EMC TESTING DEPARTMENT II
Page: 25 / 42
Date : 2008/6/2 09:36:57 V4.00
Urms = 230.1V Freq = 49.984
Range: 1A
Irms = 0.125A Ipk = 0.439A
cf = 3.498
P = 20.15W S = 28.88VA pf = 0.698
THDi = 72.00% THDu = 0.10%
Class A
Test - Time : 3min -100%
Test completed, Result: PASSED
Order Freq. Iavg Imax Limit Order
Freq. Iavg Imax Limit
[Hz]
[A] [A] [A]
[Hz]
[A]
[A]
[A]
1 50
0.0858
0.089
21
1050
0
0.0028
0.1071
2 100
0.0101
0.0102
1.08
22
1100 0
0.0002
0.0836
3 150
0.0403
0.041
2.3
23
1150 0
0.0013
0.0978
4 200
0.0057
0.0057
0.43
24
1200 0
0.0002
0.0767
5 250
0.0497
0.0502
1.14
25
1250 0
0.0016
0.09
6 300
0.0052
0.0052
0.3
26
1300 0
0.0001
0.0708
7 350
0.0383
0.0388
0.77
27
1350 0
0.002
0.0833
8 400 0 0.0023
0.23
28
1400 0
0.0001
0.0657
9 450
0.0343
0.0347
0.4
29
1450 0
0.0022
0.0776
10 500 0 0.0022
0.184 30
1500 0
0.0001
0.0613
11 550 0.027
0.0273
0.33 31
1550 0
0.0021
0.0726
12 600 0 0.0006
0.1533
32
1600 0
0.0001
0.0575
13 650
0.0205
0.0207
0.21 33
1650 0
0.0019
0.0682
14 700 0 0.0008
0.1314
34
1700 0
0.0001
0.0541
15 750 0.015
0.0151
0.15 35
1750 0
0.0015
0.0643
16 800 0 0.0002
0.115 36
1800 0
0.0001
0.0511
17 850
0.0095
0.0095
0.1324
37
1850 0
0.0012
0.0608
18 900 0 0.0003
0.1022
38
1900 0
0.0001
0.0484
19 950
0.0059
0.0061
0.1184
39
1950 0
0.0007
0.0577
20 1000 0 0.0002
0.092 40
2000 0 0.0001
0.046
ELECTRONICS TESTING CENTER(ETC), TAIWAN
File No. : 08-07-RBF-038-01
EMC TESTING DEPARTMENT II
Page: 26 / 42
4.1.3.2 Harmonics Current Emissions Test Setup Photos :
ELECTRONICS TESTING CENTER(ETC), TAIWAN
File No. : 08-07-RBF-038-01
EMC TESTING DEPARTMENT II
Page: 27 / 42
4.1.4 Voltage Fluctuations and Flicker Test:
4.1.4.1 Voltage Fluctuations and Flicker Test Data:
Operating Conditions of The EUT : Operation Mode
Test Date : Jun. 02, 2008
Test Specification
EN 61000-3-3:1995/A1:2001/A2:2005
Equipment
Manufacturer
Model No.
Calibration Date
Next Cal. Date
Hormonics-1000 EMC-Partner Hormonics-1000 2007/11/30
2008/11/29
Climatic Condition
Ambient Temperature: 22 °C Relative
Humidity:
50 %RH
Power Supply System
AC Power : 230 Vac 50 Hz
Test Set-up
Floor-standing Equipment
Click on the first or last page to see other ES 150PW (serv.man4) service manuals if exist.