JBL ES 150PW (serv.man4) EMC - CB Certificate ▷ View online
ELECTRONICS TESTING CENTER(ETC), TAIWAN
File No. : 08-07-RBF-038-01
EMC TESTING DEPARTMENT II
Page: 16 / 42
Mode: Link In
Neutral
Meter Reading
Result
Limit
Margin
(dBµV) (dBµV)
(dBµV)
(dBµV)
Frequency
(MHz)
Q.P AVG
Factor
(dB)
Q.P AVG Q.P
AVG
Q.P
AVG
0.228 30.2 ---- 0.2 30.4 ---- 62.5
52.5
-32.1
----
0.567 25.3 ---- 0.3 25.6 ---- 56.0
46.0
-30.4
----
1.476 32.0 ---- 0.4 32.4 ---- 56.0
46.0
-23.6
----
1.593 28.9 ---- 0.4 29.3 ---- 56.0
46.0
-26.7
----
23.203 18.6 ---- 1.5 20.1 ---- 60.0
50.0
-39.9
----
25.234 22.9 ---- 1.5 24.4 ---- 60.0
50.0
-35.6
----
Mode: Link In
Line
Meter Reading
Result
Limit
Margin
(dBµV) (dBµV)
(dBµV)
(dBµV)
Frequency
(MHz)
Q.P AVG
Factor
(dB)
Q.P AVG Q.P
AVG
Q.P
AVG
0.341 31.3 ---- 0.3 31.6 ---- 59.2
49.2
-27.6
----
1.476 36.2 ---- 0.4 36.6 ---- 56.0
46.0
-19.4
----
1.593 33.9 ---- 0.4 34.3 ---- 56.0
46.0
-21.7
----
24.750 24.9 ---- 1.5 26.4 ---- 60.0
50.0
-33.6
----
26.667 28.0 ---- 1.7 29.7 ---- 60.0
50.0
-30.3
----
28.636 25.3 ---- 2.0 27.3 ---- 60.0
50.0
-32.7
----
Notes: 1) Place of measurement: EMC LAB. of the ETC
2) The EUT was placed 0.8m above reference ground plane.
3) The symbol of "----" means the Q.P. value is under the limit for AVG. so, the AVG.
value doesn't need to be measured.
4) The expanded uncertainty of the conducted emission tests is 2.45 dB.
ELECTRONICS TESTING CENTER(ETC), TAIWAN
File No. : 08-07-RBF-038-01
EMC TESTING DEPARTMENT II
Page: 17 / 42
Mode: Link In
Neutral
Mode: Link In
Line
ELECTRONICS TESTING CENTER(ETC), TAIWAN
File No. : 08-07-RBF-038-01
EMC TESTING DEPARTMENT II
Page: 18 / 42
4.1.1.2
Conducted Emissions Test Setup Photos:
ELECTRONICS TESTING CENTER(ETC), TAIWAN
File No. : 08-07-RBF-038-01
EMC TESTING DEPARTMENT II
Page: 19 / 42
4.1.2 Radiated Emissions Test:
4.1.2.1
Radiated Emissions Test Data:
Operating Conditions of The EUT : AV In
Test Date : Jun. 10, 2008
Test Specification
EN 55022:2006(Class B)
Equipment
Manufacturer
Model No.
Calibration Date
Next Cal. Date
Test Receiver
Rohde & Schwarz ESCS
30
2008/01/30 2009/01/29
Amplifier HP 8447D
2007/09/20
2008/09/19
Spectrum Advantest R3162
2008/01/29
2009/01/28
Bi-Log Antenna
Schaffner
CBL 6111
2008/05/24
2009/05/23
Climatic Condition
Ambient Temperature: 21 °C Relative
Humidity:
54 %RH
Power Supply System
AC Power : 230 Vac 50 Hz
Test Set-up
Floor-standing Equipment
Test data see the next pages.