ELECTRONICS TESTING CENTER(ETC), TAIWAN 
File No. : 08-07-RBF-038-01 
EMC TESTING DEPARTMENT II
       Page: 16 / 42 
 
 
 
 
Mode: Link In  
Neutral
 
Meter Reading 
Result 
Limit 
Margin 
(dBµV) (dBµV) 
(dBµV) 
(dBµV) 
Frequency 
(MHz) 
Q.P AVG 
Factor 
(dB)
 
Q.P AVG Q.P 
AVG 
Q.P 
AVG
0.228 30.2 ----  0.2 30.4 ---- 62.5 
52.5 
-32.1 
---- 
0.567 25.3 ----  0.3 25.6 ---- 56.0 
46.0 
-30.4 
---- 
1.476 32.0 ----  0.4 32.4 ---- 56.0 
46.0 
-23.6 
---- 
1.593 28.9 ----  0.4 29.3 ---- 56.0 
46.0 
-26.7 
---- 
23.203 18.6  ----  1.5  20.1  ---- 60.0 
50.0 
-39.9 
---- 
25.234 22.9  ----  1.5  24.4  ---- 60.0 
50.0 
-35.6 
---- 
 
Mode: Link In    
Line
 
Meter Reading 
Result 
Limit 
Margin 
(dBµV) (dBµV) 
(dBµV) 
(dBµV) 
Frequency 
(MHz) 
Q.P AVG 
Factor 
(dB)
 
Q.P AVG Q.P 
AVG 
Q.P 
AVG
0.341 31.3 ----  0.3 31.6 ---- 59.2 
49.2 
-27.6 
---- 
1.476 36.2 ----  0.4 36.6 ---- 56.0 
46.0 
-19.4 
---- 
1.593 33.9 ----  0.4 34.3 ---- 56.0 
46.0 
-21.7 
---- 
24.750 24.9  ----  1.5  26.4  ---- 60.0 
50.0 
-33.6 
---- 
26.667 28.0  ----  1.7  29.7  ---- 60.0 
50.0 
-30.3 
---- 
28.636 25.3  ----  2.0  27.3  ---- 60.0 
50.0 
-32.7 
---- 
Notes:  1) Place of measurement: EMC LAB. of the ETC 
2) The EUT was placed 0.8m above reference ground plane. 
3) The symbol of "----" means the Q.P. value is under the limit for AVG. so, the AVG. 
value doesn't need to be measured. 
4) The expanded uncertainty of the conducted emission tests is 2.45 dB. 
ELECTRONICS TESTING CENTER(ETC), TAIWAN 
File No. : 08-07-RBF-038-01 
EMC TESTING DEPARTMENT II
       Page: 17 / 42 
 
 
 
 
Mode: Link In 
 
Neutral
 
 
Mode: Link In 
 
Line
 
 
ELECTRONICS TESTING CENTER(ETC), TAIWAN 
File No. : 08-07-RBF-038-01 
EMC TESTING DEPARTMENT II
       Page: 18 / 42 
 
 
 
4.1.1.2 
Conducted Emissions Test Setup Photos: 
 
 
 
 
 
 
ELECTRONICS TESTING CENTER(ETC), TAIWAN 
File No. : 08-07-RBF-038-01 
EMC TESTING DEPARTMENT II
       Page: 19 / 42 
 
 
4.1.2  Radiated Emissions Test: 
4.1.2.1 
Radiated Emissions Test Data: 
Operating Conditions of The EUT : AV In 
 
Test Date :  Jun. 10, 2008
Test Specification 
EN 55022:2006(Class B) 
Equipment 
Manufacturer 
Model No. 
Calibration Date 
Next Cal. Date 
Test Receiver 
Rohde & Schwarz ESCS 
30 
2008/01/30  2009/01/29 
Amplifier HP  8447D 
2007/09/20 
2008/09/19 
Spectrum Advantest  R3162 
 2008/01/29 
2009/01/28 
Bi-Log Antenna 
Schaffner 
CBL 6111 
2008/05/24 
2009/05/23 
Climatic Condition 
Ambient Temperature:  21 °C Relative 
Humidity: 
54 %RH 
Power Supply System 
AC Power :    230   Vac  50  Hz 