JBL ENCOUNTER (serv.man4) EMC - CB Certificate ▷ View online
IEC 60950-1 1st. Ed, 2001
- Page 4 of 5 -
Order No. 27772
The following key national differences are based on requirements other than
national regulatory requirements. The bi-national standard (CAN/CSA C22.2 No.
60950-1/UL 60950 -1, First Edition) referenced above should be consulted for
further details on the national differences summarized below.
national regulatory requirements. The bi-national standard (CAN/CSA C22.2 No.
60950-1/UL 60950 -1, First Edition) referenced above should be consulted for
further details on the national differences summarized below.
1.5.1
Components of equipment must be suitable for
the application, and must comply with the
requirements of the equipment standard and
the applicable national (Canadian and/or U.S.)
component or material standards, as far as
they may apply.
The acceptance will be based on the following:
I) A component Certified by a Canadian or U.S.
National Certification Body (NCB) to a
Canadian or U.S. component standard will be
checked for correct application and use in
accordance with its specified rating. Where
necessary, it will also be subject to the
applicable tests of the equipment standard.
J) A component, which has a CB Test
Certificate for compliance with a relevant IEC
component standard, will be checked for
correct application and use in accordance with
its specified ratings. Where necessary, it will
also be subject to the applicable tests of the
equipment standard, and to the applicable
tests of the Canadian and/or U.S. component
or material standard, under the conditions
occurring in the equipment.
K) A component, which has no approval as in
A) or B) above or which is used not in
accordance with its specified ratings, will be
subject to the applicable tests of the equipment
standard, and to the applicable tests of the
Canadian and/or U.S. component or material
standard, under the conditions occurring in the
equipment.
L) Some components may require annual re-
testing, which may be carried out by the
manufacturer, CSA International or another
laboratory
the application, and must comply with the
requirements of the equipment standard and
the applicable national (Canadian and/or U.S.)
component or material standards, as far as
they may apply.
The acceptance will be based on the following:
I) A component Certified by a Canadian or U.S.
National Certification Body (NCB) to a
Canadian or U.S. component standard will be
checked for correct application and use in
accordance with its specified rating. Where
necessary, it will also be subject to the
applicable tests of the equipment standard.
J) A component, which has a CB Test
Certificate for compliance with a relevant IEC
component standard, will be checked for
correct application and use in accordance with
its specified ratings. Where necessary, it will
also be subject to the applicable tests of the
equipment standard, and to the applicable
tests of the Canadian and/or U.S. component
or material standard, under the conditions
occurring in the equipment.
K) A component, which has no approval as in
A) or B) above or which is used not in
accordance with its specified ratings, will be
subject to the applicable tests of the equipment
standard, and to the applicable tests of the
Canadian and/or U.S. component or material
standard, under the conditions occurring in the
equipment.
L) Some components may require annual re-
testing, which may be carried out by the
manufacturer, CSA International or another
laboratory
All critical components are IEC
certified. See list of critical
components in main CB report
(§1.5.01). There may be additional
requirements for components in
Canada.
certified. See list of critical
components in main CB report
(§1.5.01). There may be additional
requirements for components in
Canada.
P
2.3.1
For TNV-2 and TNV-3 circuits with other than
ringing signals and with voltages exceeding
42.4 Vp or 60 Vdc, the maximum acceptable
current through a 2000 ohm resistor (or
greater) connected across the voltage source
with other loads disconnected is 7.1 mA peak
or 30 mA dc under normal operating
conditions.
ringing signals and with voltages exceeding
42.4 Vp or 60 Vdc, the maximum acceptable
current through a 2000 ohm resistor (or
greater) connected across the voltage source
with other loads disconnected is 7.1 mA peak
or 30 mA dc under normal operating
conditions.
No TNV circuitry.
N/A
2.3.2
In the event of a single fault, the limits of 2.2.3
apply to SELV Circuits and accessible
conductive parts.
apply to SELV Circuits and accessible
conductive parts.
No TNV circuitry.
N/A
2.6.3.3
When subject to impedance testing, protective
earthing and bonding is required to be
subjected to the additional test conditions
specified.
earthing and bonding is required to be
subjected to the additional test conditions
specified.
Class III equipment.
N/A
IEC 60950-1 1st. Ed, 2001
- Page 5 of 5 -
Order No. 27772
3.2.1.2
Equipment connected to a centralized d.c.
power syste m, and having one pole of the DC
mains input terminal connected to the main
protective earthing terminal in the equipment,
is required to comply with special earthing,
wiring, marking and installation instructions
requirements
power syste m, and having one pole of the DC
mains input terminal connected to the main
protective earthing terminal in the equipment,
is required to comply with special earthing,
wiring, marking and installation instructions
requirements
Class III equipment
N/A
4.2 .8.1
Enclosures around CRT’s with a face area of
160 mm or more are required to reduce the
risk of injury due to the implosion of the CRT.
160 mm or more are required to reduce the
risk of injury due to the implosion of the CRT.
No CRTs in the equipment.
N/A
4.3.2
Equipment with handles is required to comply
with special loading tests.
with special loading tests.
The equipment has no handles.
N/A
5.1.8.3
Equipment intended to receive
telecommunication ringing signals is required
to comply with a special touch current
measurement tests.
telecommunication ringing signals is required
to comply with a special touch current
measurement tests.
No TNV circuitry.
N/A
6.2.1
Enamel coating on winding wire not
considered electrical separation unless
subjected to special investigation.
considered electrical separation unless
subjected to special investigation.
No TNV circuitry.
N/A
6.4
Equipment intended for connection to
telecommunication network outside plant cable
is required to be protected against overvoltage
from power line crosses in accordance with 6.4
and Annex NAC.
telecommunication network outside plant cable
is required to be protected against overvoltage
from power line crosses in accordance with 6.4
and Annex NAC.
No TNV circuitry.
N/A
6.5
Equipment connected to a telecommunications
network and supplied with an earphone
intended to be held against, or in the ear is
required to comply with special acoustic
pressure tests.
network and supplied with an earphone
intended to be held against, or in the ear is
required to comply with special acoustic
pressure tests.
No TNV circuitry.
N/A
M.2
Continuous ringing signals up to 16mA only
are permitted if the equipment is subject to
special installation and performance
restrictions.
are permitted if the equipment is subject to
special installation and performance
restrictions.
No TNV circuitry.
N/A
IEC 60950 3rd. Ed, 1999
- Page 1 of 1 -
Order No.
27772
APPENDIX: CHINA DEVIATIONS
Test results according to CB BULLETIN No. 107A, May 2004
Clause
Requirement - Test
Result - Remark
Ver-
dict
1.4.5, 1.6.5
The minimum supply tolerance for China is
-10% and +10% (not -10% and +6%)
-10% and +10% (not -10% and +6%)
Class III equipment.
N/A
1.7.1
A single rated voltage shall be expressed as 220
V.
When a rated voltage range is given, the range
shall cover 220 V.
When a variety of rated voltages or rated
voltage ranges are given, one of them shall be
220 V, and shall be set as 220 V when
dispatched from the factory.
Rated frequency or rated frequency shall be 50
Hz or include 50 Hz.
If a unit is not provided with a means for direct
connection to the AC mains supply, it need not
be marked with any electrical rating.
V.
When a rated voltage range is given, the range
shall cover 220 V.
When a variety of rated voltages or rated
voltage ranges are given, one of them shall be
220 V, and shall be set as 220 V when
dispatched from the factory.
Rated frequency or rated frequency shall be 50
Hz or include 50 Hz.
If a unit is not provided with a means for direct
connection to the AC mains supply, it need not
be marked with any electrical rating.
Class III equipment.
N/A
1.7.12
Instructions and equipment markings related to
safety shall be in Chinese.
safety shall be in Chinese.
Must be considered before
marketing in China.
marketing in China.
—
3.2.01
A plug complying with GB1002-1996 must be
provided for units shipped to China (this plug is
not in compliance with IEC 60083).
provided for units shipped to China (this plug is
not in compliance with IEC 60083).
Class III equipment.
N/A
IEC 60950 3
rd
Ed, 1999
- Page 1 of 1 -
Order No.
27772
APPENDIX: ISRAEL DEVIATIONS
Test results according to SI 60950 : 2000
Variations to IEC 60950:1999 for application in Israel.
Clause
Requirement - Test
Result - Remark
Ver-
dict
1.2.12.1
TN Power Distribution
The mains system in Israel in TN-S or TN-C or
TN-C-S.
The mains system in Israel in TN-S or TN-C or
TN-C-S.
Class III equipment.
N/A
1.7
Marking and Instructions
The package of the equipment shall be marked
in Hebrew, and shall include:
The package of the equipment shall be marked
in Hebrew, and shall include:
The name of the manufacturer,
The name of the product,
The country and year of production,
The name and address of the importer.
The marking shall be on a rectangular label (of
at least 52mm x 24mm). The letters height
should be at least 2mm. The color of the label
shall be in contrast to the color of the package.
at least 52mm x 24mm). The letters height
should be at least 2mm. The color of the label
shall be in contrast to the color of the package.
Must be considered before
marketing in Israel.
marketing in Israel.
—
1.7.12
Language
All instructions and warnings concerning safety
should be in the Hebrew language.
All instructions and warnings concerning safety
should be in the Hebrew language.
Must be considered before
marketing in Israel.
marketing in Israel.
—
2.101
EMC
The equipment shall comply with SI 961 part 6
(CISPR 22 + 24).
The equipment shall comply with SI 961 part 6
(CISPR 22 + 24).
Must be considered before
marketing in Israel.
marketing in Israel.
—
3.2.1.1
Connection to an a.c. mains supply
Additional note :
In Israel the mains supply plug shall comply with
the Israeli standard SI 32.
Additional note :
In Israel the mains supply plug shall comply with
the Israeli standard SI 32.
Class III equipment.
N/A
3.2.3
Permanently connected equipment
Additional note below table 3A:
Additional note below table 3A:
In Israel the diameter of the conduit
shall comply with the Electricity Law.
Class III equipment.
N/A
Click on the first or last page to see other ENCOUNTER (serv.man4) service manuals if exist.