JBL DUET III EMC - CB Certificate ▷ View online
- Page 32 of 51 -
www.nemko.com
Report No. 116366
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1, A11
Clause
Requirement – Test
Result – Remark
Verdict
required by those who operate an X-ray emission
source on which the electron acceleration voltage
does not exceed 20 kV if
1) the local dose rate at a distance of 0,1 m
from the surface does not exceed 1 μSv/h and
2) it is adequately indicated on the X-ray
emission source that
i) X-rays are generated, and
ii) the electron acceleration voltage must not
exceed the maximum value stipulated by the
manufacturer or importer.
c) A licence in accordance with clause 1 is also
not required by persons who operate an X-ray
emission source on which the electron
acceleration voltage exceeds 20 kV if
1) the X-ray emission source has been granted
a type approval, and
2) it is adequately indicated on the X-ray
emission source that
i) X-rays are generated
ii) the device stipulated by the manufacturer or
importer guarantees that the maximum
permissible local dose rate in accordance with
the type approval is not exceeded, and
iii) the electron acceleration voltage must not
exceed the maximum value stipulated by the
manufacturer or importer.
d) Furthermore, a licence in accordance with
clause 1 is also not required by persons who
operate X-ray emission sources on which the
electron acceleration voltage does not exceed
30 kV if
1) the X-rays are generated only by intrinsically
safe CRTs complying with Enclosure III, No. 6,
2) the values stipulated in accordance with
Enclosure III, No. 6.2 are limited by technical
measures and specified in the device, and
3) it is adequately indicated on the X-ray
emission source that the X-rays generated are
adequately screened by the intrinsically safe
CRT.
source on which the electron acceleration voltage
does not exceed 20 kV if
1) the local dose rate at a distance of 0,1 m
from the surface does not exceed 1 μSv/h and
2) it is adequately indicated on the X-ray
emission source that
i) X-rays are generated, and
ii) the electron acceleration voltage must not
exceed the maximum value stipulated by the
manufacturer or importer.
c) A licence in accordance with clause 1 is also
not required by persons who operate an X-ray
emission source on which the electron
acceleration voltage exceeds 20 kV if
1) the X-ray emission source has been granted
a type approval, and
2) it is adequately indicated on the X-ray
emission source that
i) X-rays are generated
ii) the device stipulated by the manufacturer or
importer guarantees that the maximum
permissible local dose rate in accordance with
the type approval is not exceeded, and
iii) the electron acceleration voltage must not
exceed the maximum value stipulated by the
manufacturer or importer.
d) Furthermore, a licence in accordance with
clause 1 is also not required by persons who
operate X-ray emission sources on which the
electron acceleration voltage does not exceed
30 kV if
1) the X-rays are generated only by intrinsically
safe CRTs complying with Enclosure III, No. 6,
2) the values stipulated in accordance with
Enclosure III, No. 6.2 are limited by technical
measures and specified in the device, and
3) it is adequately indicated on the X-ray
emission source that the X-rays generated are
adequately screened by the intrinsically safe
CRT.
2.2.4
S (NO): Requirements according to this annex,
1.7.2 and 6.1.2.1 apply.
1.7.2 and 6.1.2.1 apply.
No TNV circuits.
N/A
2.3.2
S (NO): Requirements according to this annex,
6.1.2.1 apply.
6.1.2.1 apply.
No TNV circuits.
N/A
- Page 33 of 51 -
www.nemko.com
Report No. 116366
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1, A11
Clause
Requirement – Test
Result – Remark
Verdict
2.3.3 and
2.3.4
2.3.4
S (NO): Requirements according to this annex,
1.7.2 and 6.1.2.1 apply.
1.7.2 and 6.1.2.1 apply.
No TNV circuits.
N/A
2.6.3.3
S (GB): The current rating of the circuit shall be
taken as 13 A, not 16 A.
taken as 13 A, not 16 A.
Class III equipment.
N/A
2.7.1
C: Replace the subclause as follows:
Basic requirements
To protect against excessive current, short-
circuits and earth faults in
circuits and earth faults in
PRIMARY CIRCUITS
,
protective devices shall be included either as
integral parts of the equipment or as parts of the
building installation, subject to the following, a),
b) and c):
a) except as detailed in b) and c), protective
devices necessary to comply with the
requirements of 5.3 shall be included as parts of
the equipment;
b) for components in series with the mains input
to the equipment such as the supply cord,
appliance coupler, r.f.i. filter and switch, short-
circuit and earth fault protection may be provided
by protective devices in the building installation;
c) it is permitted for
integral parts of the equipment or as parts of the
building installation, subject to the following, a),
b) and c):
a) except as detailed in b) and c), protective
devices necessary to comply with the
requirements of 5.3 shall be included as parts of
the equipment;
b) for components in series with the mains input
to the equipment such as the supply cord,
appliance coupler, r.f.i. filter and switch, short-
circuit and earth fault protection may be provided
by protective devices in the building installation;
c) it is permitted for
PLUGGABLE EQUIPMENT TYPE
B
or
PERMANENTLY CONNECTED EQUIPMENT
, to rely
on dedicated overcurrent and short-circuit
protection in the building installation, provided
that the means of protection, e.g. fuses or circuit
breakers, is fully specified in the installation
instructions.
If reliance is placed on protection in the building
installation, the installation instructions shall so
state, except that for
protection in the building installation, provided
that the means of protection, e.g. fuses or circuit
breakers, is fully specified in the installation
instructions.
If reliance is placed on protection in the building
installation, the installation instructions shall so
state, except that for
PLUGGABLE EQUIPMENT TYPE
A the building installation shall be regarded as
providing protection in accordance with the rating
of the wall socket outlet.
providing protection in accordance with the rating
of the wall socket outlet.
Class III equipment.
N/A
S (GB): To protect against excessive currents
and short-circuits in the
and short-circuits in the
PRIMARY CIRCUIT
of
DIRECT PLUG
-
IN EQUIPMENT
, protective devices
shall be included as integral parts of the
DIRECT
PLUG
-
IN EQUIPMENT
.
Not a Direct Plug-In Equipment.
N/A
2.7.2 C:
Void.
Considered.
—
2.10.2
C: Replace in the first line "(see also 1.4.7)" by
"(see also 1.4.8)".
"(see also 1.4.8)".
Considered.
—
- Page 34 of 51 -
www.nemko.com
Report No. 116366
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1, A11
Clause
Requirement – Test
Result – Remark
Verdict
2.10.3.1
S (NO): Due to the IT power distribution system
used (see annex V, Fig. V.7), the
used (see annex V, Fig. V.7), the
A
.
C
.
MAINS
SUPPLY
voltage is considered to be equal to the
line-to-line voltage and will remain at 230 V in
case of a single earth fault.
case of a single earth fault.
Considered. P
3.2.1.1
S (CH): Supply cords of equipment having a
RATED CURRENT
not exceeding 10 A shall be
provided with a plug complying with SEV 1011 or
IEC 60884-1 and one of the following dimension
sheets:
IEC 60884-1 and one of the following dimension
sheets:
SEV 6532-2.1991, Plug Type 15, 3P+N+PE 250/400 V, 10 A
SEV 6533-2.1991, Plug Type 11, L+N
SEV 6533-2.1991, Plug Type 11, L+N
250 V, 10 A
SEV 6534-2.1991, Plug Type 12, L+N+PE 250 V, 10 A
In general, EN 60309 applies for plugs for
currents exceeding 10A. However, a 16 A plug
and socket-outlet system is being introduced in
Switzerland, the plugs of which are according to
the following dimension sheets, published in
February 1998:
currents exceeding 10A. However, a 16 A plug
and socket-outlet system is being introduced in
Switzerland, the plugs of which are according to
the following dimension sheets, published in
February 1998:
SEV 5932-2.1998, Plug Type 25, 3L+N+PE 230/400 V, 16 A
SEV 5933-2.1998, Plug Type 21, L+N
SEV 5933-2.1998, Plug Type 21, L+N
250 V, 16 A
SEV 5934-2.1998, Plug Type 23, L+N+PE 250 V, 16 A
Class III equipment.
N/A
S (DK): Supply cords of single-phase equipment
having a rated current not exceeding 13 A shall
be provided with a plug according to the Heavy
Current Regulations, Section 107-2-D1.
C
having a rated current not exceeding 13 A shall
be provided with a plug according to the Heavy
Current Regulations, Section 107-2-D1.
C
LASS
I
EQUIPMENT
provided with socket-outlets
with earth contacts or which are intended to be
used in locations where protection against
indirect contact is required according to the
wiring rules shall be provided with a plug in
accordance with standard sheet DK 2-1a or
DK 2-5a.
If poly-phase equipment and single-phase
equipment having a
used in locations where protection against
indirect contact is required according to the
wiring rules shall be provided with a plug in
accordance with standard sheet DK 2-1a or
DK 2-5a.
If poly-phase equipment and single-phase
equipment having a
RATED CURRENT
exceeding
13 A is provided with a supply cord with a plug,
this plug shall be in accordance with the Heavy
Current Regulations, Section 107-2-D1 or
EN 60309-2.
this plug shall be in accordance with the Heavy
Current Regulations, Section 107-2-D1 or
EN 60309-2.
Class III equipment.
N/A
- Page 35 of 51 -
www.nemko.com
Report No. 116366
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1, A11
Clause
Requirement – Test
Result – Remark
Verdict
S (ES): Supply cords of single-phase equipment
having a rated current not exceeding 10 A shall
be provided with a plug according to
UNE 20315:1994.
Supply cords of single-phase equipment having a
rated current not exceeding 2,5 A shall be
provided with a plug according to
UNE-EN 50075:1993.
C
having a rated current not exceeding 10 A shall
be provided with a plug according to
UNE 20315:1994.
Supply cords of single-phase equipment having a
rated current not exceeding 2,5 A shall be
provided with a plug according to
UNE-EN 50075:1993.
C
LASS
I
EQUIPMENT
provided with socket-outlets
with earth contacts or which are intended to be
used in locations where protection against
indirect contact is required according to the
wiring rules, shall be provided with a plug in
accordance with standard UNE 20315:1994.
If poly-phase equipment is provided with a supply
cord with a plug, this plug shall be in accordance
with UNE-EN 60309-2.
used in locations where protection against
indirect contact is required according to the
wiring rules, shall be provided with a plug in
accordance with standard UNE 20315:1994.
If poly-phase equipment is provided with a supply
cord with a plug, this plug shall be in accordance
with UNE-EN 60309-2.
Class III equipment.
N/A
S (GB): Apparatus which is fitted with a flexible
cable or cord and is designed to be connected to
a mains socket conforming to BS 1363 by means
of that flexible cable or cord and plug, shall be
fitted with a 'standard plug' in accordance with
Statutory Instrument 1768:1994 – The Plugs and
Socket etc. (Safety) Regulations 1994, unless
exempted by those regulations.
cable or cord and is designed to be connected to
a mains socket conforming to BS 1363 by means
of that flexible cable or cord and plug, shall be
fitted with a 'standard plug' in accordance with
Statutory Instrument 1768:1994 – The Plugs and
Socket etc. (Safety) Regulations 1994, unless
exempted by those regulations.
NOTE – 'Standard plug' is defined in SI 1768:1994 and
essentially means an approved plug conforming to BS 1363
or an approved conversion plug.
essentially means an approved plug conforming to BS 1363
or an approved conversion plug.
Class III equipment.
N/A
S (IE): Apparatus which is fitted with a flexible
cable or cord and is designed to be connected to
a mains socket conforming to I.S. 411 by means
of that flexible cable or cord and plug, shall be
fitted with a 13 A plug in accordance with
Statutory Instrument 525:1997 – National
Standards Authority of Ireland (section 28) (13 A
Plugs and Conversion Adaptors for Domestic
Use) Regulations 1997.
cable or cord and is designed to be connected to
a mains socket conforming to I.S. 411 by means
of that flexible cable or cord and plug, shall be
fitted with a 13 A plug in accordance with
Statutory Instrument 525:1997 – National
Standards Authority of Ireland (section 28) (13 A
Plugs and Conversion Adaptors for Domestic
Use) Regulations 1997.
Class III equipment.
N/A
3.2.3
C: Delete Note 1 and in Table 3A, delete the
conduit sizes in parentheses.
conduit sizes in parentheses.
Class III equipment.
N/A