JBL DUET III EMC - CB Certificate ▷ View online

 
 
- Page 28 of 51 - 
 
 
www.nemko.com
 
Report No.  116366 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
L.7 
Other business equipment 
 
N/A 
 
ANNEX M, CRITERIA FOR TELEPHONE RINGING SIGNALS (see 2.3.1) 
N/A 
M.1 
Introduction 
No telephone ringing signal. 
N/A 
M.2  
Method A 
 
N/A 
M.3 Method 
 
N/A 
M.3.1 Ringing 
signal 
 
N/A 
M.3.1.1 Frequency (Hz) ...................................................:
 
— 
M.3.1.2 Voltage (V) ..........................................................:
 
— 
M.3.1.3 Cadence; 
time (s), voltage (V) ............................:
 
— 
M.3.1.4 Single 
fault current (mA)......................................:
 
— 
M.3.2 Tripping 
device 
and monitoring voltage ..............:
 
N/A 
M.3.2.1 
Conditions for use of a tripping device or a 
monitoring voltage 
 
N/A 
M.3.2.2 Tripping 
device 
 
N/A 
M.3.2.3 Monitoring voltage (V) .........................................:
 
N/A 
 
ANNEX N, IMPULSE TEST GENERATORS (see 2.10.3.4, 6.2.2.1, 7.3.2 and 
clause G.5) 
N/A 
N.1 
ITU-T impulse test generators 
The impulse test generator not 
used. 
N/A 
N.2 
IEC 60065 impulse test generator 
 
N/A 
 
ANNEX P, NORMATIVE REFERENCES 
 
ANNEX Q, BIBLIOGRAPHY 
 
ANNEX R, EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL 
PROGRAMMES 
N/A 
R.1 
Minimum separation distances for unpopulated 
coated printed boards (see 2.10.6) 
The quality control programmes 
are not used. 
N/A 
R.2 
Reduced clearances (see 2.10.3) 
 
N/A 
 
ANNEX S, PROCEDURE FOR IMPULSE TESTING (see 6.2.2.3) 
N/A 
S.1 
Test equipment 
The impulse testing is not used.
N/A 
S.2 Test 
procedure 
 
N/A 
 
 
- Page 29 of 51 - 
 
 
www.nemko.com
 
Report No.  116366 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
S.3 
Examples of waveforms during impulse testing 
 
N/A 
 
ANNEX T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER 
(see 1.1.2) 
  
Considered. 
— 
 
ANNEX U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED 
INSULATION (see 2.10.5.4) 
N/A 
ANNEX V, AC POWER DISTRIBUTION SYSTEMS (see 1.6.1)  
 
V.1 
Introduction 
Class III equipment. 
N/A 
V.2 
TN power distribution systems  
 
N/A 
 
ANNEX W, SUMMATION OF TOUCH 
CURRENTS  
The equipment is not intended 
connect to telecommunication 
networks. 
N/A 
ANNEX X, MAXIMUM HEATING EFFECT IN  
TRANSRORMER TESTS (see clause C.1) 
No transformer. 
N/A 
ANNEX Y, ULTRAVIOLET LIGHT 
CONDITIONING TEST (see 4.3.13.3) 
No ultraviolet light. 
N/A 
 
 
- Page 30 of 51 - 
 
 
www.nemko.com
 
Report No.  116366 
 
TRF No.:IECEN60950_1B 
 
 
IEC 60950-1 / EN 60950-1, A11 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
CENELEC COMMON MODIFICATIONS [C], SPECIAL NATIONAL CONDITIONS [S] AND 
A-DEVIATIONS (NATIONAL DEVIATIONS) [A] (EN 60950-1:2001, A11:2004) 
General 
C: Delete all the "country" notes in the reference 
document according to the following list: 
1.1.5  
Note 2 
1.5.8 
Note 2 
1.6.1  Note  
1.7.2 
Note 4 
1.7.12 
Note 2 
2.1 
Note 
2.2.3 
Note 
2.2.4 
Note 
2.3.2  Note 2, 7, 8
2.3.3 
Note 1, 2  2.3.4 
Note 2,3  2.7.1  Note 
2.10.3.1 Note 4 
3.2.1.1  Note 
3.2.3  Note 1, 2 
3.2.5.1  Note 2 
4.3.6 
Note 1,2  4.7.2.2  Note 
4.7.3.1 Note 
6.1.2.1  Note 
6.1.2.2 Note 
6.2.2 Note 
6.2.2.1 Note 
2 6.2.2.2 
Note 
7 Note 
7.1 Note 
 
G2.1 
Note 1, 2  Annex H  Note 2 
Considered. 
 
1.2.4.1 
S (DK): Certain types of Class I appliances (see 
3.2.1.1) may be provided with a plug not 
establishing earthing conditions when inserted 
into Danish socket-outlets. 
Class III equipment. 
N/A 
1.5.1 
A (SE, Ordinance 1990:944) and  
(CH, Ordinance on environmentally hazardous 
substances SR 814.013, Annex 3.2, Mercury): 
Add the following: 
NOTE – Switches containing mercury such as thermostats, 
relays and level controllers are not allowed.
 
There are no components 
containing mercury in the 
equipment. 
N/A 
1.5.8 
S (NO): Due to the IT power system used (see 
annex V, Fig. V.7), capacitors are required to be 
rated for the applicable line-to-line voltage 
(230 V). 
Class III equipment. 
N/A 
1.7.2 
S (FI, NO, SE): C
LASS 
I
 PLUGGABLE EQUIPMENT 
TYPE 
A intended for connection to other 
equipment or a network shall, if safety relies on 
connection to protective earth or if surge 
suppressors are connected between the network 
terminals and accessible parts, have a marking 
stating that the equipment must be connected to 
an earthed mains socket-outlet. 
The marking text in the applicable countries shall 
be as follows: 
Class III equipment. The 
adaptor is separately approved.
N/A 
 
FI: "Laite on liitettävä suojamaadoitus-
koskettimilla varustettuun pistorasiaan" 
 N/A 
 
NO: "Apparatet må tilkoples jordet stikkontakt" 
 
N/A 
 
SE: "Apparaten skall anslutas till jordat uttag" 
 
N/A 
 
A (DK, Heavy Current Regulations): Supply cords 
of 
CLASS
 I 
EQUIPMENT
, which is delivered without 
a plug, must be provided with a visible tag with 
the following text: 
Vigtigt! 
 N/A 
 
 
- Page 31 of 51 - 
 
 
www.nemko.com
 
Report No.  116366 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1, A11 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
Lederen med grøn/gul isolation må kun tilsluttes 
en klemme mærket 
 
 eller  
  
If essential for the safety of the equipment, the 
tag must in addition be provided with a diagram 
which shows the connection of the other 
conductors, or be provided with the following text: 
"For tilslutning af de øvrige ledere, se 
medfølgende installationsvejledning." 
1.7.5 
S (DK): Socket-outlets for providing power to 
other equipment shall be in accordance with the 
Heavy Current Regulations, Section 107-2-D1, 
Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a, 
when used on Class I equipment. For 
STATIONARY
 
EQUIPMENT
 the socket-outlet shall be 
in accordance with Standard Sheet DK 1-1b or 
DK 1-5a. 
There are no socket outlets 
providing power to other 
appliances. 
N/A 
1.7.5 
A (DK, Heavy Current Regulations): 
CLASS
 II 
EQUIPMENT
 shall not be fitted with socket-
outlets for providing power to other equipment. 
Class III equipment. 
N/A 
1.7.12 
A (DE, Gesetz über technische Arbeitsmittel 
(Gerätesicherheitsgesetz) [Law on technical 
labour equipment {Equipment safety law}], of 23
rd
 
October 1992, Article 3, 3
rd
 paragraph, 2
nd
 
sentence, together with the "Allgemeine 
Verwaltungsvorschrift zur Durchführung des 
Zweiten Abschnitts des Gerätesicherheits-
gesetzes" [General administrative regulation on 
the execution of the Second Section of the 
Equipment safety law], of 10
th
 January 1996, 
article 2, 4
th
 paragraph item 2).  
Directions for use with rules to prevent certain 
hazards for (among others) maintenance of the 
technical labour equipment, also for imported 
technical labour equipment shall be written in the 
German language. 
NOTE: Of this requirement, rules for use even only by service 
personnel are not exempted.  
Must be considered before 
marketed in Germany. 
N/A 
1.7.15 
A (CH, Ordinance on environmentally hazardous 
substances SR 814.013): 
Annex 4.10 of SR 814.013 applies for batteries. 
There is no battery containing 
Cd or Hg in the equipment. 
N/A 
 
A (DE, Regulation on protection against hazards 
by X-ray, of 8
th
 January 1987, Article 5 
[Operation of X-ray emission source], clauses 1 
to 4): 
a) A licence is required by those who operate an 
X-ray emission source. 
b) A licence in accordance with clause 1 is not 
The unit does not emit X-ray 
radiation. 
N/A 
Page of 85