JBL DUET III EMC - CB Certificate ▷ View online
- Page 36 of 51 -
www.nemko.com
Report No. 116366
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1, A11
Clause
Requirement – Test
Result – Remark
Verdict
3.2.5.1 C:
Replace
"60245 IEC 53" by "H05 RR-F";
"60227 IEC 52" by "H03 VV-F or H03 VVH2-F";
"60227 IEC 53" by "H05 VV-F or H05 VVH2-F2".
In Table 3B, replace the first four lines by the
following:
Up to and including 6
"60227 IEC 52" by "H03 VV-F or H03 VVH2-F";
"60227 IEC 53" by "H05 VV-F or H05 VVH2-F2".
In Table 3B, replace the first four lines by the
following:
Up to and including 6
0,75
1)
Over 6 up to and including 10 (0,75)
2)
1,0
Over 10 up to and including 16 (1,0)
3)
1,5
In the Conditions applicable to Table 3B delete
the words "in some countries" in condition
the words "in some countries" in condition
1)
.
In Note 1, applicable to Table 3B, delete the
second sentence.
second sentence.
Class III equipment.
N/A
3.2.5.1
S (GB): A power supply cord with conductor of
1,25 mm
1,25 mm
2
is allowed for equipment with a rated
current over 10 A and up to and including 13 A.
Class III equipment.
N/A
3.3.4
C: In Table 3D, delete the fourth line: conductor
sizes for 10 to 13A, and replace with the
following:
Over 10 up to and including 16 1,5 to 2,5 1,5 to
4
Delete the fifth line: conductor sizes for 13 to
16 A.
sizes for 10 to 13A, and replace with the
following:
Over 10 up to and including 16 1,5 to 2,5 1,5 to
4
Delete the fifth line: conductor sizes for 13 to
16 A.
Class III equipment.
N/A
3.3.4
S (GB): The range of conductor sizes of flexible
cords to be accepted by terminals for equipment
with a
cords to be accepted by terminals for equipment
with a
RATED CURRENT
of over 10 A up to and
including 13 A is:
- 1,25 mm
- 1,25 mm
2
to 1,5 mm
2
nominal cross-sectional
area.
Class III equipment.
N/A
4.3.6
S (GB): The torque test is performed using a
socket outlet complying with BS 1363 and the
plug part of
socket outlet complying with BS 1363 and the
plug part of
DIRECT PLUG
-
IN EQUIPMENT
shall be
assessed to BS 1363: Part 1, 12.1, 12.2, 12.3,
12.9, 12.11, 12.12, 12.16 and 12.17, except that
the test of 12.17 is performed at not less than
125
12.9, 12.11, 12.12, 12.16 and 12.17, except that
the test of 12.17 is performed at not less than
125
°C.
Not a Direct Plug-In Equipment.
N/A
S (IE): D
IRECT PLUG
-
IN EQUIPMENT
is known as
plug similar devices. Such devices shall comply
with Statutory Instrument 526:1997 – National
Standards Authority of Ireland (Section 28)
(Electrical plugs, plug similar devices and
sockets for domestic use) Regulations, 1997.
with Statutory Instrument 526:1997 – National
Standards Authority of Ireland (Section 28)
(Electrical plugs, plug similar devices and
sockets for domestic use) Regulations, 1997.
Not a Direct Plug-In Equipment.
N/A
- Page 37 of 51 -
www.nemko.com
Report No. 116366
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1, A11
Clause
Requirement – Test
Result – Remark
Verdict
4.3.13.6
C: Add the following note:
NOTE Attention is drawn to 1999/519/EC: Council
Recommendation on the limitation of exposure of the general
public to electromagnetic fields 0 Hz to 300 GHz. Standards
taking into account this Recommendation are currently under
development.
Recommendation on the limitation of exposure of the general
public to electromagnetic fields 0 Hz to 300 GHz. Standards
taking into account this Recommendation are currently under
development.
No laser product used.
P
6.1.2.1
S (FI, NO, SE): Add the following text between
the first and second paragraph:
If this insulation is solid, including insulation
forming part of a component, it shall at least
consist of either
- two layers of thin sheet material, each of which
shall pass the electric strength test below, or
- one layer having a distance through insulation
of at least 0,4 mm, which shall pass the electric
strength test below.
If this insulation forms part of a semiconductor
component (e.g. an optocoupler), there is no
distance through insulation requirement for the
insulation consisting of an insulating compound
completely filling the casing, so that
the first and second paragraph:
If this insulation is solid, including insulation
forming part of a component, it shall at least
consist of either
- two layers of thin sheet material, each of which
shall pass the electric strength test below, or
- one layer having a distance through insulation
of at least 0,4 mm, which shall pass the electric
strength test below.
If this insulation forms part of a semiconductor
component (e.g. an optocoupler), there is no
distance through insulation requirement for the
insulation consisting of an insulating compound
completely filling the casing, so that
CLEARANCES
and
CREEPAGE DISTANCES
do not exist, if the
component passes the electric strength test in
accordance with the compliance clause below
and in addition
- passes the tests and inspection criteria of
2.10.8 with an electric strength test of 1,5 kV
multiplied by 1,6 (the electric strength test of
2.10.7 shall be performed using 1,5 kV), and
- is subject to
accordance with the compliance clause below
and in addition
- passes the tests and inspection criteria of
2.10.8 with an electric strength test of 1,5 kV
multiplied by 1,6 (the electric strength test of
2.10.7 shall be performed using 1,5 kV), and
- is subject to
ROUTINE TESTING
for electric
strength during manufacturing, using a test
voltage of 1,5 kV.
It is permitted to bridge this insulation with a
capacitor complying with EN 132400:1994,
subclass Y2.
A capacitor classified Y3 according to
EN 132400:1994, may bridge this insulation
under the following conditions:
- the insulation requirements are satisfied by
having a capacitor classified Y3 as defined by
EN 132400, which in addition to the Y3 testing, is
tested with an impulse test of 2,5 kV defined in
EN 60950:2000, 6.2.2.1;
- the additional testing shall be performed on all
the test specimens as described in EN 132400;
- the impulse test of 2,5 kV is to be performed
before the endurance test in EN 132400, in the
voltage of 1,5 kV.
It is permitted to bridge this insulation with a
capacitor complying with EN 132400:1994,
subclass Y2.
A capacitor classified Y3 according to
EN 132400:1994, may bridge this insulation
under the following conditions:
- the insulation requirements are satisfied by
having a capacitor classified Y3 as defined by
EN 132400, which in addition to the Y3 testing, is
tested with an impulse test of 2,5 kV defined in
EN 60950:2000, 6.2.2.1;
- the additional testing shall be performed on all
the test specimens as described in EN 132400;
- the impulse test of 2,5 kV is to be performed
before the endurance test in EN 132400, in the
Fire enclosure not required, refer
to 4.7.2.
to 4.7.2.
N/A
- Page 38 of 51 -
www.nemko.com
Report No. 116366
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1, A11
Clause
Requirement – Test
Result – Remark
Verdict
sequence of tests as described in EN 132400.
6.1.2.2
S (FI, NO, SE): The exclusions are applicable for
PERMANENTLY CONNECTED EQUIPMENT
and
PLUGGABLE EQUIPMENT TYPE
B and equipment
intended to be used in a
RESTRICTED ACCESS
LOCATION
where equipotential bonding has been
applied, e.g. in a telecommunication centre, and
which has provision for a permanently connected
which has provision for a permanently connected
PROTECTIVE EARTHING CONDUCTOR
and is provided
with instructions for the installation of that
conductor by a service person.
conductor by a service person.
Fire enclosure not required, refer
to 4.7.2.
to 4.7.2.
N/A
7.1
S (FI, NO, SE): Requirements according to this
annex, 6.1.2.1 and 6.1.2.2 apply with the term
annex, 6.1.2.1 and 6.1.2.2 apply with the term
TELECOMMUNICATION NETWORK
in 6.1.2 being
replaced by the term
CABLE DISTRIBUTION SYSTEM
.
Fire enclosure not required, refer
to 4.7.2.
to 4.7.2.
N/A
G.2.1
S (NO): Due to the IT power distribution system
used (see annex V, Fig. V.7), the
used (see annex V, Fig. V.7), the
A
.
C
.
MAINS
SUPPLY
voltage is considered to be equal to the
line-to-line voltage, and will remain at 230 V in
case of a single earth fault.
case of a single earth fault.
No air filters in the equipment.
N/A
Annex H
C: Replace the last paragraph of this annex by:
At any point 10 cm from the surface of the
At any point 10 cm from the surface of the
OPERATOR ACCESS AREA
, the dose rate shall not
exceed 1
μSv/h (0,1 mR/h) (see note). Account is
taken of the background level.
Replace the notes as follows:
Replace the notes as follows:
NOTE These values appear in Directive 96/29/Euratom.
Delete Note 2.
No parts exceeding 4kV.
N/A
Annex P
C: Replace the text of this annex by:
See annex ZA.
See annex ZA.
Considered.
—
Annex Q
C: Replace the title of IEC 61032 by "Protection of persons and equipment by
enclosures – Probes for verification".
Add the following notes for the standards indicated:
enclosures – Probes for verification".
Add the following notes for the standards indicated:
P
- Page 39 of 51 -
www.nemko.com
Report No. 116366
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1, A11
Clause
Requirement – Test
Result – Remark
Verdict
Annex ZA C: NORMATIVE REFERENCES TO INTERNATIONAL PUBLICATIONS WITH
NOTE When an international publication has been modified by common modifications, indicated by
(mod), the relevant EN/HD applies.
(mod), the relevant EN/HD applies.
P
⎯
IEC 60050-151
⎯
IEC 60050-195
EN 60065:1998 + corr. June 1999
IEC 60065 (mod):1998
EN 60073:1996
IEC 60073:1996
HD 566 S1:1990
IEC 60085:1984
HD 214 S2:1980
IEC 60112:1979
HD 611.4.1.S1:1992
IEC 60216-4-1:1990
HD
21
1)
Series
IEC 60227 (mod) Series
HD
22
2)
Series
IEC 60245 (mod) Series
EN 60309 Series
IEC 60309 Series
EN 60317-43:1997
IEC 60317-43:1997
EN 60320 Series
IEC 60320 (mod) Series
HD 384.3 S2:1995
IEC 60364-3 (mod):1993
HD 384.4.41 S2:1996
IEC 60364-4-41 (mod):1992
3)
EN
132400:1994
4)
+ A2:1998 + A3:1998 + A4:2001
IEC 60384-14:1993
EN 60417-1
IEC 60417-1
HD 625.1 S1:1996 + corr. Nov. 1996
IEC 60664-1 (mod):1992
EN 60695-2-2:1994
IEC 60695-2-2:1991
EN 60695-2-11:2001
IEC 60695-2-11:2000
⎯
IEC 60695-2-20:1995
⎯
IEC 60695-10-2:1995
⎯
IEC 60695-11-3:2000
⎯
IEC 60695-11-4:2000
EN 60695-11-10:1999
IEC 60695-11-10:1999
EN 60695-11-20:1999
IEC 60695-11-20:1999
EN 60730-1:2000
IEC 60730-1:1999 (mod)
EN 60825-1:1994 + corr. Febr. 1995 +
A11:1996 + corr. July 1997
A11:1996 + corr. July 1997
IEC 60825-1:1993
EN 60825-2:2000
IEC 60825-2:2000
⎯
IEC 60825-9:1999
EN 60851-3:1996
IEC 60851-3:1996
EN 60851-5:1996
IEC 60851-5:1996
EN 60851-6:1996
IEC 60851-6:1996
⎯
IEC 60885-1:1987
EN 60990:1999
IEC 60990:1999
⎯
IEC 61058-1:2000
EN 61965:2001
IEC 61965:2000
EN ISO 178:1996
ISO 178:1993
Click on the first or last page to see other DUET III service manuals if exist.