4.5
TABLE: Thermal requirements
P
Supply voltage (V) .....................
264V/60Hz(adapter)
⎯
Maximum measured temperature T of
part/at::
part/at::
T (
°C)
Allowed
T
max
(
°C)
Supplied 1KHz sine wave for speakers in computer speaker system and obtain 1/8 Maximum non-clipped
output power
output power
Adapter enclosure
45.5
81
C2 body
62.1
71
PCB near U2
75.7
91
L2 body
68.9
91
L3 body
70.5
91
PCB near U3 and Q1
83.9
91
Enclosure inside near back
44.9
--
Enclosure outside near back
32.5
81
Ambient 26.0
--
Having a specified maximum ambient temperature of 40°C, the maximum temperatures are calculated
based upon a (minimum) test temperature of 26°C. Temp. limits are adjusted according to Cl. 1.4.12.3.
Temperature limits include less 10K for thermocouple measurement method.
based upon a (minimum) test temperature of 26°C. Temp. limits are adjusted according to Cl. 1.4.12.3.
Temperature limits include less 10K for thermocouple measurement method.
Temperature T of winding:
t
1
(°C)
R
1
(
Ω)
t
2
(°C)
R
2
(
Ω)
T (
°C)
Allowed
T
max
(
°C)
Insulatio
n class
supplementary information:
4.5.2
TABLE: ball pressure test of thermoplastic parts
N/A
allowed
impression
diameter (mm) .....................:
≤ 2 mm
—
part
test temperature
(
°C)
impression diameter
(mm)
supplementary information:
- Page 49 of 51 -
www.nemko.com
Report No. 116366
TRF No.:IECEN60950_1B
4.7
TABLE: resistance to fire
N/A
part
manufacturer of material
type of material
thickness
(mm)
flammability
class
supplementary information:
5.1
TABLE: touch current measurement
N/A
Measured between:
Measured
(mA)
Limit
(mA)
Comments/conditions
Class III equipment.
supplementary information:
5.2
TABLE: electric strength tests, impulse tests and voltage surge tests
N/A
test voltage applied between:
test voltage (V)
a.c. / d.c.
breakdown
Yes / No
Class III equipment.
supplementary information
- Page 50 of 51 -
www.nemko.com
Report No. 116366
TRF No.:IECEN60950_1B
5.3
TABLE: Fault condition tests
P
Ambient temperature (
°C) ...................................: 25°C
⎯
Power source for EUT: Manufacturer, model/type,
output rating .........................................................:
output rating .........................................................:
Refer to page 41
⎯
Component
No.
Fault
Supply
voltage
(V)
Test time
Fuse #
Fuse
current
(A)
Observation
U2 pin 12-35
s-c
264
10min
F1
(inside
adapter)
0.037
Unit shutdown, no hazardous.
Q1(G-S) s-c
264
10min
F1
(inside
adapter)
0.081
Normal operation, no
hazardous.
hazardous.
Q1(D-S) s-c
264
10min
F1
(inside
adapter)
0.077
Normal operation, no
hazardous.
hazardous.
Q1(G-D) s-c
264
10min
F1
(inside
adapter)
0.031
Normal operation, no
hazardous.
hazardous.
C36 s-c
264
10min
F1
(inside
adapter)
0.03
Unit shutdown, no hazards.
C13 s-c
264
10min
F1
(inside
adapter)
0.061
Unit shutdown, no hazards.
Speaker
output
output
s-c 264 45min F1
(inside
adapter)
0.347→
0.019
Unit operated normally,
no hazards, no damaged. Max.
measured temp. in
PCB near U3= 89.6°C,
Enclosure=27.3°C,
ambient= 25.9°C
no hazards, no damaged. Max.
measured temp. in
PCB near U3= 89.6°C,
Enclosure=27.3°C,
ambient= 25.9°C
supplementary information:
s-c = short circuit
- Page 51 of 51 -
www.nemko.com
Report No. 116366
TRF No.:IECEN60950_1B
C.2 TABLE:
transformers
N/A
Loc.
Tested insulation
Working
voltage
peak / V
(2.10.2)
voltage
peak / V
(2.10.2)
Working
voltage
rms / V
(2.10.2)
voltage
rms / V
(2.10.2)
Required
electric
strength
(5.2)
electric
strength
(5.2)
Required
clearance /
mm
(2.10.3)
clearance /
mm
(2.10.3)
Required
creepage
distance /
mm
(2.10.4)
creepage
distance /
mm
(2.10.4)
Required
distance
thr. insul.
(2.10.5)
distance
thr. insul.
(2.10.5)
Loc.
Tested insulation
Test
voltage/
V
voltage/
V
Measured
clearance /
mm
clearance /
mm
Measured
creepage
dist./ mm
creepage
dist./ mm
Measured
distance
thr. insul. /
mm;
number of
layers
distance
thr. insul. /
mm;
number of
layers
supplementary information:
Click on the first or last page to see other DUET III service manuals if exist.