JBL DUET III EMC - CB Certificate ▷ View online
- Page 20 of 51 -
www.nemko.com
Report No. 116366
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
4.3.13.1 General
Refer
below:
—
4.3.13.2 Ionizing
radiation
The equipment does not
generate ionizing radiation.
generate ionizing radiation.
N/A
Measured
radiation (pA/kg) .................................:
—
Measured
high-voltage (kV) ................................:
—
Measured
focus
voltage (kV) ...............................:
—
CRT
markings ......................................................:
—
4.3.13.3
Effect of ultraviolet (UV) radiation on materials
The equipment does not
produce significant UV
radiation.
produce significant UV
radiation.
N/A
Part, property, retention after test, flammability
classification ........................................................:
classification ........................................................:
N/A
4.3.13.4
Human exposure to ultraviolet (UV) radiation .....: The equipment does not
produce significant UV
radiation.
radiation.
N/A
4.3.13.5
Laser (including LEDs)
No laser product used.
N/A
Laser
class
..........................................................:
—
4.3.13.6 Other
types ..........................................................: The equipment does not
generate other types of
radiation.
radiation.
N/A
4.4
Protection against hazardous moving parts
—
4.4.1
General
No moving parts.
N/A
4.4.2
Protection in operator access areas
N/A
4.4.3
Protection in restricted access locations
N/A
4.4.4
Protection in service access areas
N/A
4.5 Thermal
requirements
—
4.5.1
Maximum temperatures
(see appended table 4.5)
P
Normal load condition per Annex L .....................:
Rated load with continuous
operation.
operation.
—
4.5.2
Resistance to abnormal heat
No thermoplastic parts carrying
hazardous voltages.
hazardous voltages.
N/A
4.6
Openings in enclosures
—
- Page 21 of 51 -
www.nemko.com
Report No. 116366
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
4.6.1
Top and side openings
No top and side openings, unit
is supplied with LPS adaptor
evaluated in this test report and
class III equipment. (refer to
summary of testing)
is supplied with LPS adaptor
evaluated in this test report and
class III equipment. (refer to
summary of testing)
N/A
Dimensions (mm) ...............................................:
—
4.6.2
Bottoms of fire enclosures
No bottom openings, unit is
supplied with LPS adaptor
evaluated in this test report and
class III equipment. (refer to
summary of testing)
supplied with LPS adaptor
evaluated in this test report and
class III equipment. (refer to
summary of testing)
N/A
Construction
of the bottom ..................................:
—
4.6.3
Doors or covers in fire enclosures
No doors or covers.
N/A
4.6.4
Openings in transportable equipment
The unit is not regarded as
transportable equipment.
transportable equipment.
N/A
4.6.5
Adhesives for constructional purposes
No barrier secured by adhesive
inside enclosure.
inside enclosure.
N/A
Conditioning temperature (
°C)/time (weeks).......:
—
4.7
Resistance to fire
—
4.7.1
Reducing the risk of ignition and spread of flame
Equipment is class III
equipment, powered from a
LPS adaptor evaluated in this
test report. (refer to summary of
testing)
equipment, powered from a
LPS adaptor evaluated in this
test report. (refer to summary of
testing)
P
Method 1, selection and application of
components wiring and materials
components wiring and materials
Equipment is class III
equipment, powered from a
LPS adaptor evaluated in this
test report. (refer to summary of
testing)
equipment, powered from a
LPS adaptor evaluated in this
test report. (refer to summary of
testing)
P
Method 2, application of all of simulated fault
condition tests
condition tests
N/A
4.7.2
Conditions for a fire enclosure
Equipment is class III
equipment, powered from a
LPS adaptor evaluated in this
test report. (refer to summary of
testing) Fire enclosure is not
considered necessary.
equipment, powered from a
LPS adaptor evaluated in this
test report. (refer to summary of
testing) Fire enclosure is not
considered necessary.
N/A
4.7.2.1
Parts requiring a fire enclosure
Refer to 4.7.2.
N/A
- Page 22 of 51 -
www.nemko.com
Report No. 116366
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
4.7.2.2
Parts not requiring a fire enclosure
Equipment is class III powered
from a LPS adaptor evaluated
in this test report. Additionally
all components are mounted on
V-1 or better material.
from a LPS adaptor evaluated
in this test report. Additionally
all components are mounted on
V-1 or better material.
P
4.7.3 Materials
—
4.7.3.1
General
Components and materials
have adequate flammability
classification. See appended
table 1.5.1.
have adequate flammability
classification. See appended
table 1.5.1.
P
4.7.3.2
Materials for fire enclosures
Fire enclosure not required,
refer to 4.7.2.
refer to 4.7.2.
N/A
4.7.3.3
Materials for components and other parts outside
fire enclosures
fire enclosures
Fire enclosure not required,
refer to 4.7.2.
refer to 4.7.2.
N/A
4.7.3.4
Materials for components and other parts inside
fire enclosures
fire enclosures
Fire enclosure not required,
refer to 4.7.2.
refer to 4.7.2.
N/A
4.7.3.5
Materials for air filter assemblies
No air filters in the equipment.
N/A
4.7.3.6
Materials used in high-voltage components
No parts exceeding 4kV.
N/A
5
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS
—
5.1
Touch current and protective conductor current
N/A
5.1.1
General
Class III equipment.
N/A
5.1.2
Equipment under test (EUT)
N/A
5.1.3 Test
circuit
N/A
5.1.4
Application of measuring instrument
N/A
5.1.5 Test
procedure
N/A
5.1.6 Test
measurements
N/A
Test
voltage (V) ................................................. :
—
Measured touch current (mA) ............................ :
—
Max. allowed touch current (mA) ....................... :
—
Measured protective conductor current (mA) .... :
—
Max. allowed protective conductor current (mA) :
—
5.1.7
Equipment with touch current exceeding 3.5 mA
............................................................................ :
N/A
5.1.8
Touch currents to telecommunication networks
and cable distribution systems and from
telecommunication networks
and cable distribution systems and from
telecommunication networks
Not connected to a
telecommunication network.
telecommunication network.
N/A
- Page 23 of 51 -
www.nemko.com
Report No. 116366
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
5.1.8.1
Limitation of the touch current to a
telecommunication network and a cable
distribution system
telecommunication network and a cable
distribution system
N/A
Test
voltage (V) ................................................. :
—
Measured touch current (mA) ............................ :
—
Max. allowed touch current (mA) ....................... :
—
5.1.8.2
Summation of touch currents from
telecommunication networks .............................. :
telecommunication networks .............................. :
N/A
5.2 Electric
strength
—
5.2.1
General
Class III equipment.
N/A
5.2.2
Test procedure
N/A
5.3
Abnormal operating and fault conditions
—
5.3.1
Protection against overload and abnormal
operation
operation
(see appended table 5.3)
P
5.3.2
Motors
There are no motors in the
equipment.
equipment.
N/A
5.3.3
Transformers
No isolating transformers.
N/A
5.3.4 Functional
insulation........................................... :
Complies with c)
P
5.3.5
Electromechanical components
No electromechanical
components in secondary
circuits.
components in secondary
circuits.
N/A
5.3.6
Simulation of faults
See the enclosed fault
condition tests.
condition tests.
P
5.3.7 Unattended
equipment
No
thermostats, temperature
limiters or thermal cut-outs
N/A
5.3.8
Compliance criteria for abnormal operating and
fault conditions
fault conditions
No fire or molten metal
occurred and no deformation of
enclosure during the tests.
occurred and no deformation of
enclosure during the tests.
P
6
CONNECTION TO TELECOMMUNICATION NETWORKS
—
6.1
Protection of telecommunication network service persons, and users of other
equipment connected to the network, from hazards in the equipment
equipment connected to the network, from hazards in the equipment
N/A
6.1.1
Protection from hazardous voltages
N/A
6.1.2
Separation of the telecommunication network from earth
N/A
6.1.2.1
Requirements
No TNV circuits in the
equipment.
equipment.
N/A
Click on the first or last page to see other DUET III service manuals if exist.