JBL DUET III EMC - CB Certificate ▷ View online
- Page 12 of 51 -
www.nemko.com
Report No. 116366
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
2.3.3
Separation from hazardous voltages
No TNV circuits in the
equipment.
equipment.
N/A
Insulation
employed.............................................:
—
2.3.4
Connection of TNV circuits to other circuits
No TNV circuits in the
equipment.
equipment.
N/A
Insulation
employed.............................................:
—
2.3.5
Test for operating voltages generated externally
No TNV circuits in the
equipment.
equipment.
N/A
2.4
Limited current circuits
—
2.4.1
General requirements
No limited current circuits.
N/A
2.4.2 Limit
values
—
Frequency
(Hz)....................................................:
—
Measured
current (mA) .......................................:
—
Measured
voltage (V) ..........................................:
—
Measured capacitance (
μF).................................:
—
2.4.3
Connection of limited current circuits to other
circuits
circuits
—
2.5
Limited power sources
—
Inherently limited output
Class III equipment powered by
Limited Power Source adaptor
certified by IEC 60950-1.
Therefore all outputs are
considered to be limited power.
(refer to summary of testing)
Limited Power Source adaptor
certified by IEC 60950-1.
Therefore all outputs are
considered to be limited power.
(refer to summary of testing)
N/A
Impedance limited output
N/A
Overcurrent protective device limited output
N/A
Regulating network limited output under normal
operating and single fault condition
operating and single fault condition
N/A
Regulating network limited output under normal
operating conditions and overcurrent protective
device limited output under single fault condition
operating conditions and overcurrent protective
device limited output under single fault condition
N/A
Output voltage (V), output current (A), apparent
power (VA)......................................................... :
power (VA)......................................................... :
—
Current rating of overcurrent protective device (A)
—
2.6
Provisions for earthing and bonding
—
- Page 13 of 51 -
www.nemko.com
Report No. 116366
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
2.6.1
Protective earthing
Class III equipment
N/A
2.6.2 Functional
earthing
N/A
2.6.3
Protective earthing and protective bonding
conductors
conductors
N/A
2.6.3.1 General
N/A
2.6.3.2
Size of protective earthing conductors
N/A
Rated current (A), cross-sectional area (mm
2
),
AWG ....................................................................:
—
2.6.3.3
Size of protective bonding conductors
N/A
Rated current (A), cross-sectional area (mm
2
),
AWG ....................................................................:
—
2.6.3.4
Resistance (
Ω) of earthing conductors and their
terminations, test current (A) ...............................:
N/A
2.6.3.5 Colour
of
insulation..............................................:
N/A
2.6.4 Terminals
N/A
2.6.4.1 General
N/A
2.6.4.2
Protective earthing and bonding terminals
N/A
Rated current (A), type and nominal thread
diameter (mm) .....................................................:
diameter (mm) .....................................................:
—
2.6.4.3
Separation of the protective earthing conductor
from protective bonding conductors
from protective bonding conductors
N/A
2.6.5
Integrity of protective earthing
N/A
2.6.5.1
Interconnection of equipment
N/A
2.6.5.2
Components in protective earthing conductors
and protective bonding conductors
and protective bonding conductors
N/A
2.6.5.3
Disconnection of protective earth
N/A
2.6.5.4
Parts that can be removed by an operator
N/A
2.6.5.5 Parts
removed
during servicing
N/A
2.6.5.6 Corrosion
resistance
N/A
2.6.5.7
Screws for protective bonding
N/A
2.6.5.8
Reliance on telecommunication network or cable
distribution system
distribution system
N/A
2.7
Overcurrent and earth fault protection in primary circuits
—
2.7.1
Basic requirements
Class III equipment.
N/A
Instructions when protection relies on building
installation
installation
N/A
- Page 14 of 51 -
www.nemko.com
Report No. 116366
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
2.7.2
Faults not covered in 5.3
N/A
2.7.3
Short-circuit backup protection
N/A
2.7.4
Number and location of protective devices ....... :
N/A
2.7.5
Protection by several devices
N/A
2.7.6
Warning to service persons ............................... :
N/A
2.8 Safety
interlocks
—
2.8.1
General principles
No safety interlocks.
N/A
2.8.2 Protection
requirements
N/A
2.8.3 Inadvertent
reactivation
N/A
2.8.4 Fail-safe
operation
N/A
2.8.5 Moving
parts
N/A
2.8.6 Overriding
N/A
2.8.7
Switches and relays
N/A
2.8.7.1 Contact
gaps (mm) ............................................ :
N/A
2.8.7.2 Overload
test
N/A
2.8.7.3 Endurance
test
N/A
2.8.7.4
Electric strength test
N/A
2.8.8 Mechanical
actuators
N/A
2.9 Electrical
insulation
—
2.9.1
Properties of insulating materials
Class III equipment.
N/A
2.9.2 Humidity
conditioning
N/A
Humidity (%) .......................................................:
—
Temperature (
°C) ................................................:
—
2.9.3
Grade of insulation
N/A
2.10
Clearances, creepage distances and distances through insulation
—
2.10.1
General
Class III equipment.
N/A
2.10.2
Determination of working voltage
N/A
2.10.3 Clearances
N/A
2.10.3.1 General
N/A
2.10.3.2
Clearances in primary circuits
N/A
2.10.3.3
Clearances in secondary circuits
N/A
- Page 15 of 51 -
www.nemko.com
Report No. 116366
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
2.10.3.4
Measurement of transient voltage levels
N/A
2.10.4 Creepage
distances
N/A
CTI
tests ............................................................. :
—
2.10.5 Solid
insulation
N/A
2.10.5.1
Minimum distance through insulation
N/A
2.10.5.2
Thin sheet material
N/A
Number of layers (pcs) ....................................... :
—
Electric strength test
—
2.10.5.3 Printed
boards
N/A
Distance through insulation
N/A
Electric strength test for thin sheet insulating
material
material
—
Number of layers (pcs) ....................................... :
N/A
2.10.5.4 Wound
components
N/A
Number of layers (pcs) ....................................... :
N/A
Two wires in contact inside wound component;
angle between 45
angle between 45
° and 90° ............................... :
N/A
2.10.6
Coated printed boards
N/A
2.10.6.1 General
N/A
2.10.6.2
Sample preparation and preliminary inspection
N/A
2.10.6.3 Thermal
cycling
N/A
2.10.6.4
Thermal ageing (
°C) ........................................... :
N/A
2.10.6.5
Electric strength test
—
2.10.6.6
Abrasion resistance test
N/A
Electric strength test
—
2.10.7 Enclosed
and
sealed parts ................................. :
N/A
Temperature T
1
=T
2
= T
ma
– T
amb
+10K (
°C) ....... :
N/A
2.10.8
Spacings filled by insulating compound ............. :
N/A
Electric strength test
—
2.10.9
Component external terminations
N/A
2.10.10
Insulation with varying dimensions
N/A
3
WIRING, CONNECTIONS AND SUPPLY
—
3.1 General
—