JBL BALBOA SUB10 (serv.man2) EMC - CB Certificate ▷ View online

 
Page 5 of 44 
Report Ref No.: 614376 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065E 
 
TRF Originator: ASTABEAB 
 
6 HAZARDOUS 
RADIATION 
 
6.1 
Ionizing radiation < 36 pA/kg (0,5 mR/h) 
 
N/A 
6.2 
Laser radiation, emission limits to IEC 60825-1 ..  
N/A 
 
Emission limits under fault conditions  .............. :  
N/A 
 
 
HEATING UNDER NORMAL OPERATING CONDITIONS 
 
7.1 
Temperature rises not exceeding specified 
values, any single protective device defeated 
except those of Cl. 7.1 a) and b) 
 P 
7.1.1 
Temperature rise of accessible parts 
 
7.1.2 
Temperature rise of parts providing electrical 
insulation 
 P 
7.1.3 
Temperature rise of parts acting as a support or 
as a mechanical barrier 
 P 
7.1.4 
Temperature rise of windings 
 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0,2 A at least 150
 o
 N/A 
 
 
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION 
AGAINST ELECTRIC SHOCK 
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare 
 P 
8.2 
No shock hazard when changing voltage 
setting device, fuse-links or handling drawers 
etc. 
 N/A 
8.3 
Insulation of hazardous live parts not provided 
by hygroscopic material 
Not used 
8.4 
No risk of electric shock following the removal 
of a cover which can be removed by hand 
 P 
8.5 
Class I equipment 
 
 
 
Basic insulation between hazardous live parts 
and earthed accessible parts 
 N/A 
 
Capacitors bridging basic insulation complying 
with 14.2.1 a) 
 N/A 
8.6 
Class II equipment and Class II constructions within Class I equipment 
 
Page 6 of 44 
Report Ref No.: 614376 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065E 
 
TRF Originator: ASTABEAB 
 
Reinforced or double insulation between 
hazardous live parts and accessible parts 
 P 
 
Components bridging reinforced or double 
insulation complying with 14.1 a) or 14.3 
Mains transformer 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.2.1 a) 
 N/A 
 
Reinforced or double insulation being bridged 
with 2 capacitors in series complying with 
14.2.1 a) 
 N/A 
 
Reinforced or double insulation being bridged 
with a single capacitor complying with 14.2.1 b) 
 N/A 
 
Basic insulation bridged by components 
complying with 14.3.4.3 
 N/A 
8.7 
Basic insulation between parts at 35 V to 71 V 
(peak) a.c. or 60 V to 120 V d.c. and accessible 
parts 
This clause is not considered  
N/A 
 
Reinforced or double insulation between 
circuits operating at voltages between 35 V and 
71 V (peak) a.c. or between 60 V and 120 V 
d.c. and hazardous live parts at higher voltage 
 N/A 
 
Separation by Class II isolating transformer 
 
N/A 
 
Separation by Class I transformer 
 
N/A 
 
Separation by earthed conductive part 
 
N/A 
8.8 
Double Insulation: the Basic or Supplementary 
insulation > 0,4 mm (mm)  ................................. :
Primary wires 
 
Reinforced insulation > 0,4 mm (mm)  .............. : Transformer bobbin 
 
Thin sheet insulation used inside the enclosure.  
N/A 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3 dielectric 
 N/A 
 
Basic or supplementary insulation, three layers 
any two of which meet 10.3 dielectric 
 N/A 
 Reinforced 
insulation, 
two layers each of which 
meet 10.3 dielectric 
 
N/A 
 
Reinforced insulation, three layers any two 
which meet 10.3 dielectric 
 N/A 
8.9 
Primary Wiring: Adequate insulation between 
internal hazardous live conductors and 
accessible parts 
Applies to class I appliance 
N/A 
 
Secondary Wiring: Adequate insulation 
between internal hazardous live parts and 
conductors connected to accessible parts 
 N/A 
 
Page 7 of 44 
Report Ref No.: 614376 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065E 
 
TRF Originator: ASTABEAB 
8.10 Class 
II 
Wiring: 
(1) Primary: Double insulation between 
conductors connected to the mains and 
accessible parts. 
(2) Secondary: Double insulation between 
conductors connected to accessible parts and 
the mains 
 
Live wires are double insulated.  
 
No sec. wires can come into contact 
with live parts 
8.11 Detaching 
of 
wires 
 
No undue reduction of creepages or clearance 
distances if wires become detached 
No risk of any wire becoming 
detached 
N/A 
 
Vibration test carried out  ................................... :  No, no need. See above 
N/A 
8.12 
Adequate cross-sectional area of internal wiring 
to mains socket-outlets 
 N/A 
8.13 
Adequate fastening of windows, lenses, lamp 
covers etc. (pull test 20 N for 10 s) 
 P 
8.14 
Adequate fastening of covers (pull test 50 N for 
10 s) 
 P 
8.15 
No risk of damage to the insulation of internal 
wiring due to hot parts or sharp edges (2N 
force) 
 P 
8.16 
Only special supply equipment can be used 
 
N/A 
8.17 
Insulated winding wire without additional 
interleaved insulation 
 N/A 
8.18 
Endurance test as required by 8.17 
 
N/A 
8.19 
Disconnection from the mains 
 
 
8.19.1 Disconnect 
device 
Mains 
plug 
 
All-pole switch or circuit breaker with >3mm 
contact separation 
 N/A 
8.19.2 
Mains switch ON indication 
 
8.20 
Switch not fitted in the mains cord 
 
N/A 
8.21 
Bridging components comply with clause 14 
 
 
 
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS 
 
9.1 
Testing on the outside 
 
9.1.1 
For voltages >1000 V ac or >1500 V dc 
complies 
with clause 13.3.1 for basic insulation  
 N/A 
9.1.1.1    
a) 
Determination of Hazardous Live parts 
 
 
Page 8 of 44 
Report Ref No.: 614376 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065E 
 
TRF Originator: ASTABEAB 
b)  Touch current measured from terminal devices 
using the network in annex D  ........................... :
See table 9.1 
c)  Discharge not exceeding 45 μC  
N/A 
d)  Energy of discharge not exceeding 350 mJ 
 
N/A 
9.1.1.2 
Test with test finger and test probe 
 
9.1.2 
No hazardous live shafts of knobs, handles or 
levers 
 P 
9.1.3 
Ventilation holes tested by means of 
4 mm x 100 mm test pin 
 N/A 
9.1.4 
Terminal devices - within 25mm tested with 
1 mm x 20 mm test pin (10 N); test probe D of 
IEC 61032 
 P 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032 
 P 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm 
test pin (10 N); test probe C of IEC 61032 
 N/A 
9.1.6 
No shock hazard due to stored charge on 
withdrawal of the mains plug; voltage (V) after 
2 s  ...................................................................... :
 N/A 
 
If C is not greater than 0,1 μF no test needed 
 
9.1.7 
Enclosure sufficiently resistant to external force   
a) 
Test probe 11 of IEC 61032 for 10 s (50 N) 
 
b) 
Test hook of fig. 4 for 10 s (20 N) 
 
c) 
Conductive enclosure: 30 mm diameter test tool 
for 5 s (100 or 250 N) ........................................ :
250N P 
9.2 
No hazard 2s after removing a cover by hand 
 
N/A 
 
 
10 INSULATION 
REQUIREMENTS 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. 
after surge test for basic and 4 MΩ min. for 
reinforced insulation .......................................... :
 
N/A 
10.2 
Humidity treatment 48 h or 120 h  ..................... : Both 48 and 120h ( see also page 42 )
10.3 
Insulation resistance and dielectric strength 
 
 
 
11 FAULT 
CONDITIONS 
11.1 
No shock hazard under fault condition 
 
11.2 
Heating under fault condition 
 
 
 
No hazard from softening solder 
 
 
No flaming more than 10s 
 
Page of 56
Display

Click on the first or last page to see other BALBOA SUB10 (serv.man2) service manuals if exist.