JBL BALBOA SUB10 (serv.man2) EMC - CB Certificate ▷ View online
Page 5 of 44
Report Ref No.: 614376
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No.: IEC60065E
TRF Originator: ASTABEAB
6 HAZARDOUS
RADIATION
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
N/A
6.2
Laser radiation, emission limits to IEC 60825-1 ..
N/A
Emission limits under fault conditions .............. :
N/A
7
HEATING UNDER NORMAL OPERATING CONDITIONS
7.1
Temperature rises not exceeding specified
values, any single protective device defeated
except those of Cl. 7.1 a) and b)
values, any single protective device defeated
except those of Cl. 7.1 a) and b)
P
7.1.1
Temperature rise of accessible parts
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
P
7.1.3
Temperature rise of parts acting as a support or
as a mechanical barrier
as a mechanical barrier
P
7.1.4
Temperature rise of windings
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
N/A
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
P
8.2
No shock hazard when changing voltage
setting device, fuse-links or handling drawers
etc.
setting device, fuse-links or handling drawers
etc.
N/A
8.3
Insulation of hazardous live parts not provided
by hygroscopic material
by hygroscopic material
Not used
P
8.4
No risk of electric shock following the removal
of a cover which can be removed by hand
of a cover which can be removed by hand
P
8.5
Class I equipment
Basic insulation between hazardous live parts
and earthed accessible parts
and earthed accessible parts
N/A
Capacitors bridging basic insulation complying
with 14.2.1 a)
with 14.2.1 a)
N/A
8.6
Class II equipment and Class II constructions within Class I equipment
Page 6 of 44
Report Ref No.: 614376
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No.: IEC60065E
TRF Originator: ASTABEAB
Reinforced or double insulation between
hazardous live parts and accessible parts
hazardous live parts and accessible parts
P
Components bridging reinforced or double
insulation complying with 14.1 a) or 14.3
insulation complying with 14.1 a) or 14.3
Mains transformer
P
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
bridged by a capacitor complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged
with 2 capacitors in series complying with
14.2.1 a)
with 2 capacitors in series complying with
14.2.1 a)
N/A
Reinforced or double insulation being bridged
with a single capacitor complying with 14.2.1 b)
with a single capacitor complying with 14.2.1 b)
N/A
Basic insulation bridged by components
complying with 14.3.4.3
complying with 14.3.4.3
N/A
8.7
Basic insulation between parts at 35 V to 71 V
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
This clause is not considered
N/A
Reinforced or double insulation between
circuits operating at voltages between 35 V and
71 V (peak) a.c. or between 60 V and 120 V
d.c. and hazardous live parts at higher voltage
circuits operating at voltages between 35 V and
71 V (peak) a.c. or between 60 V and 120 V
d.c. and hazardous live parts at higher voltage
N/A
Separation by Class II isolating transformer
N/A
Separation by Class I transformer
N/A
Separation by earthed conductive part
N/A
8.8
Double Insulation: the Basic or Supplementary
insulation > 0,4 mm (mm) ................................. :
insulation > 0,4 mm (mm) ................................. :
Primary wires
P
Reinforced insulation > 0,4 mm (mm) .............. : Transformer bobbin
P
Thin sheet insulation used inside the enclosure.
N/A
Basic or supplementary insulation, at least two
layers, each meeting 10.3 dielectric
layers, each meeting 10.3 dielectric
N/A
Basic or supplementary insulation, three layers
any two of which meet 10.3 dielectric
any two of which meet 10.3 dielectric
N/A
Reinforced
insulation,
two layers each of which
meet 10.3 dielectric
N/A
Reinforced insulation, three layers any two
which meet 10.3 dielectric
which meet 10.3 dielectric
N/A
8.9
Primary Wiring: Adequate insulation between
internal hazardous live conductors and
accessible parts
internal hazardous live conductors and
accessible parts
Applies to class I appliance
N/A
Secondary Wiring: Adequate insulation
between internal hazardous live parts and
conductors connected to accessible parts
between internal hazardous live parts and
conductors connected to accessible parts
N/A
Page 7 of 44
Report Ref No.: 614376
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No.: IEC60065E
TRF Originator: ASTABEAB
8.10 Class
II
Wiring:
(1) Primary: Double insulation between
conductors connected to the mains and
accessible parts.
conductors connected to the mains and
accessible parts.
(2) Secondary: Double insulation between
conductors connected to accessible parts and
the mains
conductors connected to accessible parts and
the mains
Live wires are double insulated.
No sec. wires can come into contact
with live parts
with live parts
P
8.11 Detaching
of
wires
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
No risk of any wire becoming
detached
detached
N/A
Vibration test carried out ................................... : No, no need. See above
N/A
8.12
Adequate cross-sectional area of internal wiring
to mains socket-outlets
to mains socket-outlets
N/A
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
covers etc. (pull test 20 N for 10 s)
P
8.14
Adequate fastening of covers (pull test 50 N for
10 s)
10 s)
P
8.15
No risk of damage to the insulation of internal
wiring due to hot parts or sharp edges (2N
force)
wiring due to hot parts or sharp edges (2N
force)
P
8.16
Only special supply equipment can be used
N/A
8.17
Insulated winding wire without additional
interleaved insulation
interleaved insulation
N/A
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
8.19.1 Disconnect
device
Mains
plug
P
All-pole switch or circuit breaker with >3mm
contact separation
contact separation
N/A
8.19.2
Mains switch ON indication
P
8.20
Switch not fitted in the mains cord
N/A
8.21
Bridging components comply with clause 14
P
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
9.1
Testing on the outside
9.1.1
For voltages >1000 V ac or >1500 V dc
complies
with clause 13.3.1 for basic insulation
complies
with clause 13.3.1 for basic insulation
N/A
9.1.1.1
a)
a)
Determination of Hazardous Live parts
P
Page 8 of 44
Report Ref No.: 614376
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No.: IEC60065E
TRF Originator: ASTABEAB
b) Touch current measured from terminal devices
using the network in annex D ........................... :
See table 9.1
P
c) Discharge not exceeding 45 μC
N/A
d) Energy of discharge not exceeding 350 mJ
N/A
9.1.1.2
Test with test finger and test probe
P
9.1.2
No hazardous live shafts of knobs, handles or
levers
levers
P
9.1.3
Ventilation holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
N/A
9.1.4
Terminal devices - within 25mm tested with
1 mm x 20 mm test pin (10 N); test probe D of
IEC 61032
1 mm x 20 mm test pin (10 N); test probe D of
IEC 61032
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm
test pin (10 N); test probe C of IEC 61032
test pin (10 N); test probe C of IEC 61032
N/A
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after
2 s ...................................................................... :
withdrawal of the mains plug; voltage (V) after
2 s ...................................................................... :
N/A
If C is not greater than 0,1 μF no test needed
P
9.1.7
Enclosure sufficiently resistant to external force
P
a)
Test probe 11 of IEC 61032 for 10 s (50 N)
P
b)
Test hook of fig. 4 for 10 s (20 N)
P
c)
Conductive enclosure: 30 mm diameter test tool
for 5 s (100 or 250 N) ........................................ :
for 5 s (100 or 250 N) ........................................ :
250N P
9.2
No hazard 2s after removing a cover by hand
N/A
10 INSULATION
REQUIREMENTS
10.1
Insulation resistance (MΩ) at least 2 MΩ min.
after surge test for basic and 4 MΩ min. for
reinforced insulation .......................................... :
after surge test for basic and 4 MΩ min. for
reinforced insulation .......................................... :
N/A
10.2
Humidity treatment 48 h or 120 h ..................... : Both 48 and 120h ( see also page 42 )
P
10.3
Insulation resistance and dielectric strength
P
11 FAULT
CONDITIONS
11.1
No shock hazard under fault condition
P
11.2
Heating under fault condition
No hazard from softening solder
P
No flaming more than 10s
P
Click on the first or last page to see other BALBOA SUB10 (serv.man2) service manuals if exist.