JBL BALBOA SUB10 (serv.man2) EMC - CB Certificate ▷ View online
Page 13 of 44
Report Ref No.: 614376
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No.: IEC60065E
TRF Originator: ASTABEAB
PTC-S devices (15 W) category V-1 or better
N/A
14.5.4
Circuit protectors have adequate breaking
capacity and their position is correctly marked
capacity and their position is correctly marked
N/A
14.6 Switches
14.6.1 a)
Separate testing to IEC 61058 including:
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3
V-0 compliance with annex G, G.1.1
and
Peak inrush rating of switch
Measured/calculated inrush............................... :
Calculated = 22A
P
14.6.1 b)
Tested in the apparatus:
N/A
Switch controlling > 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
N/A
Switch controlling > 0.2A with open contact
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
N/A
Switch controlling = 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
N/A
14.6.2
Switch tested to 14.6.1 b) constructed to IEC
61058-1 subclause 13.1 and has
making/breaking action independent of speed
of actuation
61058-1 subclause 13.1 and has
making/breaking action independent of speed
of actuation
N/A
14.6.3
Switch tested to 14.6.1 b) compliant with IEC
61058-1 subclause 16.2.2 d), l) and m) not
attaining excessive temperatures in use
61058-1 subclause 16.2.2 d), l) and m) not
attaining excessive temperatures in use
N/A
14.6.4
Switch tested to 14.6.1 b) has adequate
dielectric strength
dielectric strength
N/A
14.6.5 Mains
switch
controlling mains socket outlets
additional tests to IEC 61058-1
N/A
Socket outlet current marking correct
N/A
14.7 Safety
interlocks
Safety interlocks to 2.8 of IEC 60950
N/A
14.8 Voltage
setting
devices
Voltage setting device not likely to be changed
accidentally
accidentally
N/A
14.9 Motors
N/A
14.9.1
Endurance test on motors
N/A
Page 14 of 44
Report Ref No.: 614376
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No.: IEC60065E
TRF Originator: ASTABEAB
Motor start test
N/A
Dielectric
strength
test
N/A
14.9.2
Not adversely affected by oil or grease etc.
N/A
14.9.3
Protection against moving parts
N/A
14.9.4
Motors with phase-shifting capacitors, three-
phase motors and series motors meet
clause. B.8, B.9 and B.10 of IEC 60950,
Annex B
phase motors and series motors meet
clause. B.8, B.9 and B.10 of IEC 60950,
Annex B
N/A
14.10 Batteries
14.10.1
Batteries mounted with no risk of accumulation
of flammable gases
of flammable gases
N/A
14.10.2
No possibility of recharging non-rechargeable
batteries
batteries
N/A
14.10.3
Recharging currents and times within
manufacturers limits
manufacturers limits
N/A
Lithium batteries discharge and reverse
currents within the manufacturers limits
currents within the manufacturers limits
N/A
14.10.4
Battery mould stress relief
N/A
14.10.5
Battery drop test
N/A
14.11 Optocouplers
Optocouplers comply with Cl. 8
N/A
N/A
14.12 Surge
suppression
varistors
Comply with IEC 61051-2
N/A
Not connected between mains and accessible
parts except for earthed parts of permanently
connected apparatus
parts except for earthed parts of permanently
connected apparatus
N/A
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12
thermal stress requirements of 14.12
N/A
15 TERMINALS
15.1.1
Mains plug, appliance inlet, interconnection
couplers and mains socket-outlet meet the
appropriate standard
couplers and mains socket-outlet meet the
appropriate standard
P
15.1.2
Connectors for antenna, earth, audio, video or data:
No risk of insertion in mains socket-outlets
P
No risk of insertion into audio or video: outlets
marked with the symbol of 5.2
marked with the symbol of 5.2
N/A
Page 15 of 44
Report Ref No.: 614376
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No.: IEC60065E
TRF Originator: ASTABEAB
15.1.3
Output terminals of a.c. adaptors or similar
devices not compatible with household mains
socket-outlets
devices not compatible with household mains
socket-outlets
N/A
15.2
Provision for protective earthing
Accessible conductive parts of Class I
equipment reliably connected to earth terminal,
within equipment
equipment reliably connected to earth terminal,
within equipment
N/A
Class I supply equipment with non-hazardous
live output voltage: output circuit not connected
to earth
live output voltage: output circuit not connected
to earth
N/A
Protective earth conductors correctly coloured
N/A
Equipment with non-detachable mains cord
provided with separate protective earth terminal
near mains input
provided with separate protective earth terminal
near mains input
N/A
Earthing connection of parts removable by
hand.
hand.
N/A
Protective earth terminal resistant to corrosion
N/A
Earth resistance test: < 0,1
Ω at 25 A ............. : N/A
15.3
Terminals for external flexible cords and for permanent connection to the mains supply
15.3.1
Adequate terminals for connection of
permanent wiring
permanent wiring
N/A
15.3.2
Reliable connection of non-detachable cords:
Appliance inlet
Not soldered to conductors of a printed circuit
board
board
N/A
Adequate clearances and creepage distances
between connections should a wire break away
between connections should a wire break away
N/A
Wire secured by additional means to the
conductor
conductor
N/A
15.3.3
Screws and nuts clamping conductors have
adequate threads: ISO 261, ISO 262 or similar
adequate threads: ISO 261, ISO 262 or similar
N/A
15.3.4
Soldered conductors wrapped around terminal
prior to soldering or held in place by additional
means
prior to soldering or held in place by additional
means
N/A
Clamping of conductor and insulation if not
soldered or held by screws
soldered or held by screws
N/A
15.3.5
Terminals allow connection of appropriate
cross-sectional area of conductors, for the rated
current of the equipment
cross-sectional area of conductors, for the rated
current of the equipment
N/A
15.3.6
Terminals to 15.3.3 have sizes required by
table 16
table 16
N/A
15.3.7
Terminals clamp conductors between metal
and have adequate pressure
and have adequate pressure
N/A
Page 16 of 44
Report Ref No.: 614376
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No.: IEC60065E
TRF Originator: ASTABEAB
Terminals designed to avoid conductor slipping
out when tightened or loosened
out when tightened or loosened
N/A
Terminals adequately fixed to avoid loosening
when the clamping is tightened or loosened and
stress on internal wiring is avoided
when the clamping is tightened or loosened and
stress on internal wiring is avoided
N/A
15.3.8
Terminals carrying a current more than 0,2 A:
contact pressure not transmitted by insulating
material except ceramic
contact pressure not transmitted by insulating
material except ceramic
N/A
15.3.9
Termination of non-detachable cords: wires
terminated near to each other
terminated near to each other
N/A
Terminals located and shielded: test with 8 mm
strand
strand
N/A
15.4
Devices forming a part of the mains plug
15.4.1
No undue strain on mains socket-outlets
N/A
15.4.2
Device complies with standard for dimensions
of mains plugs
of mains plugs
N/A
15.4.3
Device has adequate mechanical strength
(tests a,b,c)
(tests a,b,c)
N/A
16 EXTERNAL
FLEXIBLE
CORDS
16.1
Mains cords sheathed type, complying with
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ...................................................... :
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ...................................................... :
PVC P
Non-detachable cords for Class I have
green/yellow core for protective earth
green/yellow core for protective earth
N/A
16.2
Mains cords conductors have adequate cross-
sectional area for rated current consumption of
the equipment
sectional area for rated current consumption of
the equipment
2x0.75mm
2
P
16.3
a) Flexible cords not complying with 16.1, used
for interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate
dielectric strength
for interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate
dielectric strength
N/A
b) Flexible cords not complying with 16.1,
withstand bending and mechanical stress (3.2
of IEC 60227-2)
withstand bending and mechanical stress (3.2
of IEC 60227-2)
N/A
16.4
Flexible cords used for connection between
equipment have adequate cross-sectional
areas to avoid temperature rise under normal
and fault conditions
equipment have adequate cross-sectional
areas to avoid temperature rise under normal
and fault conditions
N/A
16.5
Adequate strain relief on external flexible cords
N/A
Not possible to push cord back into equipment
N/A