JBL BALBOA SUB10 (serv.man2) EMC - CB Certificate ▷ View online
Page 33 of 44
Report Ref No.: 614376
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No.: IEC60065E
TRF Originator: ASTABEAB
National differences Denmark
IEC 60065:2001
(See also Group Differences)
CB Bulletin 110A / DK 06 I
2.6.1 The
following
is
added:
Certain types of CLASS I apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish
socket-outlets
Justification:
Heavy Current Regulations, Section 107
may be provided with a plug not establishing
earthing continuity when inserted in Danish
socket-outlets
Justification:
Heavy Current Regulations, Section 107
N/A
15.1.1
To the first paragraph the following is added:
In Denmark, supply cords of single phase
appliances having a rated current not exceeding
13 A shall be provided with a plug according to
the Heavy Current Regulations Section 107-2-D1.
Appliances of CLASS I provided with socket-
outlets with earth contact or which are intended to
be used in locations where protection against
indirect contact is required according to the wiring
rules shall be provided with a plug in accordance
with the Heavy Current Regulations Section 107-
2-D1 standard sheet DK 2-1a.
To the second paragraph the following is added:
Socket outlets intended for provided power to
CLASS II apparatus with a rated current of 2.5 A
shall have the following demensions:
In Denmark, supply cords of single phase
appliances having a rated current not exceeding
13 A shall be provided with a plug according to
the Heavy Current Regulations Section 107-2-D1.
Appliances of CLASS I provided with socket-
outlets with earth contact or which are intended to
be used in locations where protection against
indirect contact is required according to the wiring
rules shall be provided with a plug in accordance
with the Heavy Current Regulations Section 107-
2-D1 standard sheet DK 2-1a.
To the second paragraph the following is added:
Socket outlets intended for provided power to
CLASS II apparatus with a rated current of 2.5 A
shall have the following demensions:
Dimensions in mm
Other dimensions shall be in compliance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DKA 1-3 for portable socket-
outlets. Shutters are not required.
To the third paragraph the following is added:
Mains socket-outlets with earthing contact shall
be in compliance with the Heavy Current
Regulations, Section 107-2-D1, Standard Sheet
DK 1-3a, DK 1-5a or DK 1-7a.
Justification
Other dimensions shall be in compliance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DKA 1-3 for portable socket-
outlets. Shutters are not required.
To the third paragraph the following is added:
Mains socket-outlets with earthing contact shall
be in compliance with the Heavy Current
Regulations, Section 107-2-D1, Standard Sheet
DK 1-3a, DK 1-5a or DK 1-7a.
Justification
:
Heavy Current Regulations, Section 107
P
Page 34 of 44
Report Ref No.: 614376
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No.: IEC60065E
TRF Originator: ASTABEAB
National differences United Kingdom
IEC 60065:2001
(See also Group Differences)
CB Bulletin 110A / GB 06 I
15.1.1
Apparatus which is fitted with a flexible cable or
cord and is designed to be connected to a mains
socket conforming to BS 1363 by means of that
flexible cable or cord and plug shall be fitted with
a ”standard plug” in accordance with Statutory
Instrument 1768: 1994: The Plugs and Sockets
etc. (Safety) Regulations 1994, unless exempted
by those Regulations.
NOTE ”Standard plug” is defined in SI 1768:1994
and essentially means an approved plug
conforming to BS 1363 or an approved
conversion plug.
Justification
cord and is designed to be connected to a mains
socket conforming to BS 1363 by means of that
flexible cable or cord and plug shall be fitted with
a ”standard plug” in accordance with Statutory
Instrument 1768: 1994: The Plugs and Sockets
etc. (Safety) Regulations 1994, unless exempted
by those Regulations.
NOTE ”Standard plug” is defined in SI 1768:1994
and essentially means an approved plug
conforming to BS 1363 or an approved
conversion plug.
Justification
: SI 1768: 1994
P
Page 35 of 44
Report Ref No.: 614376
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No.: IEC60065E
TRF Originator: ASTABEAB
National differences Norway
IEC 60065:2001
(See also Group Differences)
CB Bulletin 110A / NO 06 I
13.3.1
To the second paragraph the following is added:
In Norway, due to the IT power distribution
system used, the a.c. MAINS supply voltage is
considered to be equal to the line-to-line voltage,
and will remain 230 V in case of a single earth
fault.
Justification:
Based on a use in Norway of an IT power
distribution system where the neutral is not
provided.
In Norway, due to the IT power distribution
system used, the a.c. MAINS supply voltage is
considered to be equal to the line-to-line voltage,
and will remain 230 V in case of a single earth
fault.
Justification:
Based on a use in Norway of an IT power
distribution system where the neutral is not
provided.
N/A
15.1.1
Mains socket-outlets mounted on CLASS II
apparatus shall comply with the specifications
given in CEE Publ. 7 as fas as a Applicable, with
the following amendments:
§ 8 Dimensions
a 2.5 A 250 V two-pole socket-outlets for
electronic apparatus shall comply with the
enclosed Standard Sheet I.
apparatus shall comply with the specifications
given in CEE Publ. 7 as fas as a Applicable, with
the following amendments:
§ 8 Dimensions
a 2.5 A 250 V two-pole socket-outlets for
electronic apparatus shall comply with the
enclosed Standard Sheet I.
Justification:
Act of 24 May 1929 relating to supervision of
electrical installation (TEA 1929/FEL 1998).
Act of 24 May 1929 relating to supervision of
electrical installation (TEA 1929/FEL 1998).
P
Page 36 of 44
Report Ref No.: 614376
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No.: IEC60065E
TRF Originator: ASTABEAB
J.2
After Table J.1 the following is added:
In Norway, due to the IT power distribution
system used, the a.c. MAINS supply voltage is
considered to be equal to the line-to-line voltage,
and will remain 230 V in case of a single earth
fault.
Justification
In Norway, due to the IT power distribution
system used, the a.c. MAINS supply voltage is
considered to be equal to the line-to-line voltage,
and will remain 230 V in case of a single earth
fault.
Justification
:
Based on a use in Norway of an IT power
distribution system where the neutral is not
provided.
distribution system where the neutral is not
provided.
N/A